        1.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Response modification factors of school facilities for non-seismic RC moment frames with partial masonry infills in ‘Manual for Seismic Performance Evaluation and Retrofit of School Facilities’ published in 2018 were investigated in the preceding study. However, since previous studies are based on 2D frame analysis and limited analysis conditions, additional verification needs to be performed to further apply various conditions including orthogonal effect of seismic load. Therefore, this study is to select appropriate response modification factors of school facilities for non-seismic RC moment frames with partial masonry infills by 3D frame analysis. The results are as follows. An appropriate response modification factor for non-seismic RC moment frames with partial masonry infills is proposed as 2.5 for all cases if the period is longer than 0.6 seconds. Also if the period is less than 0.4 seconds and the ratio of shear-controlled columns is less than 30%, 2.5 is chosen too. However, if the period is less than 0.4 seconds and the ratio of shear-controlled columns is higher than 30%, the response modification factor shall be reduced to 2.0. If the period is between 0.4 and 0.6 seconds, then linearly interpolates the response correction factor.
        4,000원
        2.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most school buildings consist of reinforced concrete (RC) moment frames with masonry infills. The longitudinal direction frames of those school buildings are relatively weak due to the short-column effects caused by the partial masonry infills and need to be evaluated carefully. In ‘Manual for Seismic Performance Evaluation and Retrofit of School Facilities’ published in 2018, response modification factor of 2.5 is applied to non-seismic RC moment frames with partial masonry infills, but sufficient verification of the factor has not been reported yet. Therefore, this study conducted seismic performance evaluation of planar RC moment frames with partial masonry infills in accordance with both linear analysis and nonlinear static analysis procedures presented in the manual. The evaluation results from the different procedures are compared in terms of assessed performance levels and number of members not meeting target performance objectives. Finally, appropriate response modification factors are proposed with respect to a shear-controlled column ratio.
        4,300원
        3.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of earthquake resistant design for typical bridges is the ‘No Collapse Design’ allowing emergency vehicles just after earthquakes. The Roadway Bridge Design Code provides design provisions to carry out such ‘No Collapse Design’ with a ductile mechanism and response modification factors given for connections and substructure play key role in this procedure. In case of response modification factors for substructure, the Roadway Bridge Design Code provides values considering ductility and redundancy. On the other hand, ‘AASHTO LRFD Bridge Design Specifications’ provides values considering additionally an artificial factor according to the bridge importance categories divided into critical, essential and others. In this study, a typical bridge with steel bearing connections and reinforced concrete piers is selected and different response modification factors for substructure are applied with design conditions given in the Roadway Bridge Design Code. Based on the comparison study of the design results, supplementary measures are suggested required by applying different response modification factors for substructure.
        4,000원
        4.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        도로교설계기준 내진설계편은 붕괴방지수준의 확보를 설계절차에 의해 규정하고 있는 반면 기능수행수준의 확보에 대 한 요구사항은 명확하게 제시하고 있지 않다. 붕괴방지수준의 확보를 위해 기본적으로 제시된 설계방법은 응답수정계수를 사용하는 스펙트럼해석법으로, 기능수행수준은 설계과정에 적용되는 위험도계수와 응답수정계수에 의해 결정 되어진다. 위 험도계수는 교량의 중요도에 따라 단순하게 적용할 수 있으나 중약진지역에서의 응답수정계수 적용은 설계조건에 따라 다 른 결과를 갖게 된다. 이 연구에서는 중약진지역의 일반 도로교량을 대상으로 내진설계를 수행하여 기능수행수준의 결정과 정을 검토하고, 이 결과를 토대로 기능수행수준의 확보와 관련하여 내진설계편에 보완해야 하는 사항을 제시하였다.
        4,000원
        5.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 높은 지진의 위험이 내재된 지역에 위치한 3층, 9층 그리고 20층 철골 모멘트저항골조에 대한 반응수정계수와 주기의 영향을 평가하기 위한 것이다. 각 구조물들은 IBC 2000과 KBC 2005에서 제시하고 있는 8의 반응수정계수로 설계되었고 건물에 기대되는 최소의 성능과 최대의 성능을 평가하기 위해서 상한범위와 하한범위의 설계가 고려되었다. 또한 반응수정계수에 대한 영향을 조사하기 위하여 4개의 다른 반응수정계수들이(9, 10, 11, 12) 각 구조물에 대하여 적용되었고 각 구조물의 고유주기 값 외의 4개의 다른 주기를 추가로 적용하여 구조물의 동적거동시 주기에 대한 영향을 조사하였다. 총 150개의 해석모델들은 50년 동안 2%의 초과확률(재현 주기 2500년)을 가진 20개의 지반운동에 대하여 평가되었다. 구조물의 성능평가를 위하여 정적 Pushover와 비선형 시간이력해석이 수행되었으며 구조물의 연성능력을 평가하기 위해서 변위연성요구가 고려되었다. 3층과 9층 구조물은 변위연성요구 값이 비교적 안정적인 거동을 보인 반면 20층 구조물은 동적 불안정성을 야기하는 요소에 의해 민감하게 나타나는 것으로 조사되었다.
        4,000원
        6.
        2004.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 현행 내진설계방법에 따라 설계된 역V형 보통 가새골조 (OCBF)의 비선형 정적 해석을 수행하고, 그 결과를 바탕으로 초과강도계수, 연성계수, 반응수정계수 및 변위 증폭계수 등을 산정하였다. 해석결과에 따르면 대부분의 해석모델에서 현행 내진설계 기준에서 제시한 값보다 작은 초과강도계수 및 반응수정계수 값을 가지는 것으로 나타났다. 그러나 수직 보강 기둥 (zipper column)으로 가새를 보강한 경우 초과강도계수 및 반등수정계수는 보통 가새 구조물에 비하여 상당히 증가하는 것으로 나타났다.
        4,000원
        7.
        2004.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        초과강도계수와 연성계수는 현행 내진기준에서 사용되는 반응수정계수를 결정하기 위한 두 가지 중요한 계수이다. 본 논문에서는 다양한 층수 및 경간을 갖는 역V형 특수 중심가새골조의 비선형 정적 해석을 수행하여 초과강도계수와 연성계수를 구하고 이를 이용하여 반응 수정계수를 산정하였다. 해석결과에 따르면 저층 구조물의 경우 IBC-2000에서 제시한 값보다 큰 반응수정계수 값을 가지며, 중층 이상의 경우 기준에서 제시한 값보다 작은 값으로 나타났다. 또한 초과강도계수와 연성계수는 구조물의 높이가 감소할수록, 스팬의 길이가 증가할수록 증가하는 것으로 나타났다.
        4,000원
        8.
        2012.11 서비스 종료(열람 제한)
        In this study response modification factors of rectangular reinforced concrete staggered wall system (SWS) structures were evaluated according to ATC-63. The adjusted collapse margin ratios of the model structures obtained from incremental dynamic analyses turned out to be larger than the specified limit states, which implies that the analysis model structures have enough safety margin for collapse against design level earthquakes. It also was concluded that the response modification factor, 6 used in the design of the model structures was valid.