논문 상세보기

Laboratory Tests for Determining Temperature Limits of Fiber Optic Accelerometer for HLW Disposal Repository

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/431214
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

High level radioactive waste (HLW) final disposal repository is faced thermos-hydro-mechanical - radioactive condition because it is placed over 500 m in depth and waste emits decay heats for decades. Repository will be operated around 100 years and will be closed after all the wastes are disposed. The integrity of engineered barriers including buffer, backfill, concrete plug and canister and natural barrier (natural rock mass) will be stood during operating periods. Monitoring sensors for concrete and rock mass is conducted using piezo based sensors such as accelerometer or acoustic emission (AE) sensors. Typical accelerometer for harsh conditions is commonly expensive and data/power cable can be a potential groundwater inflow and nuclide outflow path. The fiber optic accelerometer whose data and power cable are united and has limited volume. Therefore, it can be a potential alternative sensor of piezo based sensors. The temperature limits and accelerated tests for fiber optic sensors are conducted. Most of sensors gives a malfunction around 130°C. The results of these experimental tests give a possibility of communications in compacted bentonite buffer and will be utilized for the design of monitoring systems for the repository.

저자
  • Jin-Seop Kim(Korea Atomic Energy Research Institute (KAERI))
  • Chang-Ho Hong(Korea Atomic Energy Research Institute (KAERI)) Corresponding author