검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 35

        1.
        2023.11 구독 인증기관·개인회원 무료
        High level radioactive waste (HLW) final disposal repository is faced thermos-hydro-mechanical - radioactive condition because it is placed over 500 m in depth and waste emits decay heats for decades. Repository will be operated around 100 years and will be closed after all the wastes are disposed. The integrity of engineered barriers including buffer, backfill, concrete plug and canister and natural barrier (natural rock mass) will be stood during operating periods. Monitoring sensors for concrete and rock mass is conducted using piezo based sensors such as accelerometer or acoustic emission (AE) sensors. Typical accelerometer for harsh conditions is commonly expensive and data/power cable can be a potential groundwater inflow and nuclide outflow path. The fiber optic accelerometer whose data and power cable are united and has limited volume. Therefore, it can be a potential alternative sensor of piezo based sensors. The temperature limits and accelerated tests for fiber optic sensors are conducted. Most of sensors gives a malfunction around 130°C. The results of these experimental tests give a possibility of communications in compacted bentonite buffer and will be utilized for the design of monitoring systems for the repository.
        2.
        2023.11 구독 인증기관·개인회원 무료
        The operation time of a disposal repository is generally more than one hundred years except for the institutional control phase. The structural integrity of a repository can be regarded as one of the most important research issues from the perspective of a long-term performance assessment, which is closely related to the public acceptance with regard to the nuclear safety. The objective of this study is to suggest the methodology for quantitative evaluation of structural integrity in a nuclear waste repository based on the adaptive artificial intelligence (AI), fractal theory, and acoustic emission (AE) monitoring. Here, adaptive AI means that the advanced AI model trained additionally based on the expert’s decision, engineering & field scale tests, numerical studies etc. in addition to the lab. test. In the process of a methodology development, AE source location, wave attenuation, the maximum AE energy and crack type classification were subsequently studied from the various lab. tests and Mazars damage model. The developed methodology for structural integrity was also applied to engineering scale concrete block (1.3 m × 1.3 m × 1.3 m) by artificial crack generation using a plate jacking method (up to 30 MPa) in KURT (KAERI Underground Research Tunnel). The concrete recipe used in engineering scale test was same as that of Gyeongju low & intermediate level waste repository. From this study, the reliability for AE crack source location, crack type classification, and damage assessment increased and all the processes for the technology development were verified from the Korea Testing Laboratory (KTL) in 2022.
        3.
        2023.11 구독 인증기관·개인회원 무료
        The high-level nuclear waste (HLW) repository disposes of high-level nuclear waste at a depth of 500 m to 1,000 m underground. Structural health monitoring must be accompanied by the complex environmental conditions of high temperature, high humidity, radiation, and mechanical stress. A thermocouple for measuring temperature, total stress meter and pore pressure meter for measuring stress and water pressure, relative hygrometer and electrical resistivity sensor (TDR or SUS) for measuring humidity, accelerometer for measuring crack signals, and strain gauge for measuring displacement are used. For safety, after disposing of HLW in the HLW repository, access to the disposal tunnel gets blocked, making it impossible to replace or remove the monitoring sensors. So, it is necessary to evaluate the effect of the HLW repository’s environmental conditions on the monitoring sensors and enhance their durability through quantitative life evaluation and shielding. Before evaluating the life of accelerometers and strain gauges used in the HLW repository, an experimental study is conducted to determine failure modes and failure mechanisms under radiation conditions, which are unique environmental conditions of the HLW repository.
        4.
        2023.11 구독 인증기관·개인회원 무료
        In the nuclear environment, sensors ensure safety, monitoring, and operational efficiency under various operating conditions. These sensors come in various forms, each tailored to specific purposes, including nuclear safety and security, waste treatment and storage, gas leak detection, temperature and humidity monitoring, and corrosion detection. Ensuring the longevity of sensors without the need for frequent replacements is a vital goal for researchers in this field. This paper explores materials that can act as shields to protect sensors from harsh environmental conditions (high radiation and temperatures) to enhance their lifetime. The types of material that had been explored were divided into categories: metal and non-metal. Fourteen types of metal and seven different plastic materials were studied and focused on their characteristics and current applications. Considering properties like melting point, intensity, and conductivity, plastic materials are chosen to be examined as sensor shielding material. A preliminary experiment was conducted to verify signal characteristics changes by shielding material. Metal material and plastic material each were placed in the middle of the granite and the target sensor. The result showed that when metal is between the granite and the sensor, the density and impedance are higher in granite than in the metal. This leads to signal attenuation and a shift in resonance frequency, while plastic does not. Therefore, PPS (Polyphenylene sulfide) and PAI (Polyamide-imide) have lower density and impedance than granite while also possessing heat, moisture, and radiation resistance for effective shielding.
        5.
        2023.11 구독 인증기관·개인회원 무료
        The engineered barrier system (EBS), composed of spent nuclear fuel, canister, buffer and backfill material, and near-field rock, plays a crucial role in the deep geological repository for high-level radioactive waste. Understanding the interactions between components in a thermo-hydro-mechanical -chemical (THMC) environment is necessary for ensuring the long-term performance of a disposal facility. Alongside the research project at KAERI, a comprehensive experimental facility has been established to elucidate the comprehensive performance of EBS components. The EBS performance demonstration laboratory, which installed in a 1,000 m2, consists of nine experimental modules pertaining to rock mechanics, gas migration, THMC characteristics, buffer-rock interaction, buffer & backfill development, canister corrosion, canister welding, canister performance, and structure monitoring & diagnostics. This facility is still conducting research on the engineering properties and complex interactions of EBS components under coupled THMC condition. It is expected to serve as an important laboratory for the development of the key technologies for assessing the long-term stability of engineered barriers
        6.
        2023.11 구독 인증기관·개인회원 무료
        The compacted bentonite buffer is a key component of the engineered barrier system in deep geological repositories for high-level radioactive waste disposal. Groundwater infiltration into the deep geological repository leads to the saturation of the bentonite buffer. Bentonite saturation results in bentonite swelling, gelation and intrusion into the nearby rock discontinuities within the excavation damaged zone of the adjacent rock mass. Groundwater flow can result in the erosion and transport of bentonite colloids, resulting in bentonite mass loss which can negatively impact the long-term integrity and safety of the overall engineered barrier system. The hydro -mechanicalchemical interactions between the buffer, surrounding host rock and groundwater influence the erosion characteristics of the bentonite buffer. Hence, assessing the critical hydro-mechanicalchemical factors that negatively affect bentonite erosion is crucial for the safety design of the deep geological repository. In this study, the effects of initial bentonite density, aperture, discontinuity angle and groundwater chemistry on the erosion characteristics of Bentonil WRK are investigated via bentonite extrusion and artificial fracture experiments. Both experiments examine bentonite swelling and intrusion into simulated rock discontinuities; cylindrical holes for bentonite extrusion experiments and plane surfaces for artificial fracture experiments. Compacted bentonite blocks and bentonite pellets are manufactured using a compaction press and granulation compactor respectively and installed in the transparent extrusion cells and artificial fracture cells. The reference test condition is set to be 1.6 g/cm3 dry density and saturation using distilled water. After distilled water or solution injection, the axial and radial expansion of the bentonite specimens into the simulated rock discontinuities are monitored for one month under free swelling conditions with no groundwater flow. Subsequent flow tests are conducted using the artificial fracture cell to determine the critical flow rate for bentonite erosion. The intrusion and erosion characteristics are modelled using a modified hydro-mechanicalchemical coupled dynamic bentonite diffusion model and a fluid-based hydro-mechanical penetration model.
        7.
        2023.11 구독 인증기관·개인회원 무료
        The presence of technological voids in deep geological repositories for high-level radioactive nuclear waste can have negative effects on the hydro-mechanical properties of the engineered barrier system when groundwater infiltrates from the surrounding rock. This study conducted hydration tests along with image acquisition and X-ray CT analysis on compacted Korean bentonite samples, which simulated technological voids filling to investigate the behavior of fracturing (piping erosion) and cracking deterioration. We utilized a dual syringe pump to inject water into a cell consisting of a bentonite block and technological voids at a consistent flow rate. The results showed that water inflow to fill technological voids led to partial hydration and self-sealing, followed by the formation of an erosional piping channel along the wetting front. After the piping channel generated, the cyclic filling-piping stage is characterized by the repetitive accumulation and drop of water pressure, accompanied by the opening and closing of piping channels. The stoppage of water inflow leads to the formation of macro- and micro cracks in bentonite due to moisture migration caused by high suction pressure. These cracks create preferential flow paths that promote longterm groundwater infiltration. The experimental test and analysis are currently ongoing. Further experiments will be conducted to investigate the effects of different dry density in bentonite, flow rate, and chemical composition of injected water.
        8.
        2023.11 구독 인증기관·개인회원 무료
        The concept of deep geological disposal for high-level radioactive waste is based on an engineered barrier system (EBS), including a canister, bentonite buffer and backfill material. The bentonite buffer is key component of the EBS to prevent groundwater infiltration and radionuclide leakage. However, the bentonite buffer can become saturated due to groundwater flow through the excavation damaged zone in the adjacent rock, causing erosion of bentonite buffer and affecting the long-term performance of EBS. While the RH (relative humidity) sensor is commonly used to assess the degree of saturation in the bentonite buffer, it has a critical challenge due to its sensor size, which can disturb the overall integrity of the bentonite buffer during the initial installation process. In contrasts, the electrical resistivity test, widely known as a non-destructive method, is used to predict soil properties such as the degree of saturation and water contents. This method measures the electric resistance of materials using electric current induced by electric potential difference between two electrodes. Notably, there is no study that assess the integrity of bentonite buffer in a nuclear waste repository using electrical resistivity measurement. This study presents the electrical resistance numerical module under steady state using commercial finite element method (FEM), and quantitatively estimate the change of electrical resistance according to saturation and erosion of bentonite buffer. Furthermore, the electric potential and current density distribution formed between two electrodes are analyzed.
        9.
        2023.05 구독 인증기관·개인회원 무료
        The engineered barrier system (EBS) for deep geological disposal of high-level radioactive waste requires a buffer material that can prevent groundwater infiltration, protect the canister, dissipate decay heat effectively, and delay the transport of radioactive materials. To meet those stringent performance criteria, the buffer material is prepared as a compacted block with high-density using various press methods. However, crack and degradation induced by stress relaxation and moisture changes in the compacted bentonite blocks, which are manufactured according to the geometry of the disposal hole, can critically affect the performance of the buffer. Therefore, it is imperative to develop an adequate method for quality assessment of the compacted buffer block. Recently, several non-destructive testing methods, including elastic wave measurement technology, have been attempted to evaluate the quality and aging of various construction materials. In this study, we have evaluated the compressive wave velocity of compacted bentonite blocks via the ultrasonic velocity method (UVM) and free-free resonant column method (FFRC), and analyzed the relationship among compressive wave velocity, dry density, thermal conductivity, and strength parameter. We prepared compacted bentonite block specimens using the cold isostatic pressure (CIP) method under different water content and CIP pressure conditions. Based on multiple regression analysis, we suggest a prediction model for dry density in terms of manufacturing conditions. Additionally, we propose an empirical model to predict thermal conductivity and unconfined compressive strength based on compressive wave velocity. The database and suggested models in this study can contribute to the development of quality assessment and prediction techniques for compacted buffer blocks used in the construction of a disposal repository.
        10.
        2023.05 구독 인증기관·개인회원 무료
        High level radioactive waste disposal repository is faced thermos-hydro-mechanical-radioactive condition. Factors according to these complex conditions are measured using multiple sensors installed in the disposal repository to check integrity of the structure. Wires of the sensors can be potential pathways of groundwater and nuclide flow and these pathways accelerates bentonite saturation. Therefore, it is worth to developing wireless sensors buried in the bentonite buffer which can communicate without wires. In start of the study, widely-utilized wireless communication methods including WiFi and LoRa are tested using compacted bentonite blocks to estimate the performance of them. Compacted bentonite blocks are prepaired using di-press method with metal molds and the dry density of them are about 1.6 g/cm3. All wireless communication methods are well communicated through the bentonite blocks over 50 cm. The further experimental tests will be conducted with different dry density and water contents. The results of these experimental tests give a possibility of wireless communications in compacted bentonite buffer and will be utilized for the design of wireless sensor systems for the repository monitoring.
        11.
        2023.05 구독 인증기관·개인회원 무료
        The high-level nuclear waste (HLW) repository is a 500-1,000 m deep underground structure to dispose high-level nuclear waste. The waste has a very long half-time and is exposed to a number of stresses, including high temperatures, high humidity, high pressure These stresses cause the structure to deteriorate and create cracks. Therefore, structural health monitoring with monitoring sensors is required for safety. However, sensors could also fail due to the stresses, especially high temperature. Given that the sensors are installed in the bentonite buffer and the backfill tunnel, it is impossible to replace them if they fail. That’s why it is necessary to assess the sensors’ durability under the repository’s environmental conditions before installing them. Accelerated life test (ALT) can be used to assess durability or life of the sensors, and it is important to obtain the same failure mode for reliability tests including ALT. Before conducting the test, the proper stress level must be designed first to get reliable data in a short time. After that, acceleration of life reduction with increasing temperature and temperature-life model should be determined with some statistical methods. In this study, a methodology for designing stress levels and predicting the life of the sensor were described.
        12.
        2023.05 구독 인증기관·개인회원 무료
        The acoustic emission (AE) method as a passive non-destructive monitoring technique is proposed for real-time monitoring of mechanical degradation in underground structures, such as deep geological disposal of high-level nuclear waste (HLW). This study investigates the low-frequency characteristics of AE signals emitted during the fracturing of meter-scale concrete specimens; uniaxial compression tests (UCT) in a lab scale and Goodman jack (GJ) tests in a 1.3 m-long concrete block were conducted while acquiring the AE signals using low-frequency AE sensors. The results indicate a sharp increase in AE energy emission at approximately 60% and 80% of the yield stresses in the UCT and GJ tests, respectively. The collected AE signals were primarily found in two frequency bands: the 4-28 kHz range and the 56-80 kHz range. High-frequency AE signals were captured more as the stress increased in the GJ tests, which was in contrast to the UCT tests. Furthermore, the AE signals obtained from the Goodman jack tests tended to lower RA values than the UCT results. This study presents unique experimental data with low-frequency AE sensors under different loading conditions, which provides insights into field-scale AE monitoring practices.
        13.
        2022.10 구독 인증기관·개인회원 무료
        The integrity of the disposal repository structure must be guaranteed for few hundreds to few hundred thousand years until toxicity of radioactive waste is surely degraded. Acoustic emission (AE) method is widely utilized to evaluate the integrity of the structure because it can detect crack wave signals of the structures. It is well known that the cracking AE energy is proportional to the volume of the structure (Fractal theory). However, it is hard to destroy whole structures for obtaining AE energy. Therefore, the scaled specimens are prepared to obtain the relationship between volume of the structure and AE energy. The specimens are prepared with same of Wolsong Low and Intermediate Level Radioactive Waste Disposal Center (WLDC) silo concrete recipe. Their diameters are from 50 mm to 150 mm in each 10 mm and their heights are twice of the diameter. One set of 50 mm to 150 mm specimens (11 specimens in one set) are made in single mixers to maintain uniformity. Surface of the specimens are flatten with cement milk to prevent from applying load with eccentricity. The uniaxial compression test is performed by controlling displacement as 0.1 mm/min. The fractal constant is obtained using least square function from volume-cumulative AE energy relationship.
        14.
        2022.10 구독 인증기관·개인회원 무료
        The high-level nuclear waste (HLW) repository is a 500-1,000 m deep geological disposal system with a very long life expectancy for disposing of high-level waste, which is known to have a half-life of several thousand years. This repository is subject to harsh environmental conditions, such as high temperature and radiation from high-level waste, that can cause deterioration and crack. When radiation escapes through cracks, it can injure persons on the ground. Therefore, it is essential to install a sensor that can detect problems such as cracks. But, since the high-level nuclear waste (HLW) repository is sealed with bentonite and backfill, the sensor cannot be removed or replaced once it has been installed. Therefore, it is necessary to develop a highly durable monitoring sensor that can withstand harsh environmental conditions. Before attempting to improve durability, it is first required to assess durability quantitatively. And an accelerated life test is a widely used method for assessing durability. However, it is important to obtain the same failure mode when conducting a reliability test, such as an accelerated life test. If the accelerated life test is conducted using different failure modes, the dependability of the results is inevitably diminished. Therefore, in this study, a representative failure mode for the piezoelectric sensor used in the accelerated life test was derived through experiments and literature research.
        15.
        2022.10 구독 인증기관·개인회원 무료
        Compacted bentonite buffer materials are a key component of the engineered barrier system for high-level radioactive waste disposal. The bentonite buffer is saturated via groundwater flow through the excavation damaged zone in the adjacent rock mass. Bentonite saturation results in bentonite swelling, gelation and intrusion into the nearby rock discontinuities. Groundwater flow can cause bentonite erosion and transportation of bentonite colloids. This bentonite mass loss can negatively impact the long-term integrity of the engineered barrier system. Hence, it is necessary to understand the effects of erosion on the properties of the bentonite buffer. In this study, a series of artificial fracture erosion experiments are conducted to investigate the erosion characteristics of compacted Ca-bentonite buffer materials for different initial dry density conditions. Compacted bentonite blocks and bentonite pellets were manufactured using the cold isostatic pressing technique and granulation compactor respectively. The specimens were placed in a custommade transparent artificial fracture cell and the bentonite intrusion characteristics were monitored for two months under free swelling conditions with no groundwater flow. The radial expansion of the bentonite specimens within the artificial fracture was measured using a digital camera. In addition, the swelling pressure, displacement, and saturation were determined using a load cell-piston system, LVDT, and electrical resistivity electrodes respectively. A hydro-mechanical-chemical coupled dynamic bentonite diffusion model was applied to model the bentonite erosion characteristics using COMSOL Multiphysics.
        16.
        2022.10 구독 인증기관·개인회원 무료
        When a rapid groundwater inflow is introduced from the adjacent rock mass in the early stage of disposal, hydraulic pressure build-up occurs, which may cause piping erosion at the buffer material itself and the interface of the gap-filling material. Such piping erosion in compacted bentonite buffer via interaction between the buffer and the adjacent rock mass may deteriorate the performance of the buffer material. Therefore, it is necessary to understand the conditions and scenarios in which the piping phenomenon around the buffer material occurs for the long-term health of the repository. In this study, laboratory-scale experimental tests of piping erosion in buffer and interfacial rock was introduced. ø 100 mm × 200 mm height compacted bentonite specimens were placed in a cylindrical acetal cell, and the distilled water was continuously injected at a flow rate of 0.068 L/min using a dual syringe pump. The inflow of water was generated from the bottom and side cell of buffer material. During water injection, injected water pressure and amount were measured with visual observation. The results showed that the external saturation of buffer firstly occurs followed by piping crack generation along the wetting front. The additional piping channels were generated and merged with others. As the injection stopped, the swelling and self-sealing behavior of buffer material were observed. Moreover, X-ray CT scanning of the cell was conducted after the piping simulation to analyze the piping channels and saturation depth. The results highlight the piping erosion phenomenon mainly occurs due to the presence of a gap outside the buffer material. Further experimental cases is need to comprehensively understand piping phenomena in buffer material for assessing the long-term stability of underground radioactive waste disposal systems.
        17.
        2022.10 구독 인증기관·개인회원 무료
        The high-level waste disposal system is an underground structure exposed to complex environmental conditions such as high temperature, radiation, and groundwater. The high-level waste disposal causes structural cracks and deterioration over time. However, since the high-level waste disposal system is a structure that should be operated for a very long time, developing a high-durability monitoring sensor to detect cracks and deterioration is essential. The durability of the sensor can be evaluated by predicting the expected life through the accelerated life test, one of the reliability qualification tests. The most important factor in the accelerated life test design is setting the harsh stress level. This study figured out the harsh stress level of the piezoelectric sensor, which is commonly used for underground structure monitoring. It is possible to determine the appropriate stress level for the accelerated life test by investigating the harsh stress level for the temperature factor. It will contribute to more accurate life expectancy prediction.
        18.
        2022.10 구독 인증기관·개인회원 무료
        The structural integrity of concrete silos is important from the perspective of long-term operation of radioactive waste repository. Recently, the application of acoustic emission (AE) is considered as a promising technology for the systematic real-time health monitoring of concrete-like brittle material. In this study, the characteristics of AE wave propagation through concrete silo of Gyeongju radioactive waste repository were evaluated under the effects of groundwater and temperature for the quantitative damage assessment. The attenuation coefficients and absolute energies of AE waves were measured for the temperature cases of 15, 45, 75°C under dry and saturated concrete specimens, which were manufactured based on the concrete mix same as that of Gyeongju concrete silo. The geometric spreading and material loss were taken into account with regard to the wave attenuation coefficient. The attenuation coefficient shows a decreasing pattern with temperature rise for both dry and saturated specimens. The AE waves in saturated condition attenuate faster than those in dry condition. It is found that the effect of water content has a greater impact on the wave attenuation than the temperature. The results from this study will be used as valuable information for estimating the quantitative damage at the location micro-cracks are generated rather than the AE sensor location.
        19.
        2022.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The acoustic emission (AE) is proposed as a feasible method for the real-time monitoring of the structural damage evolution in concrete materials that are typically used in the storage of nuclear wastes. However, the characteristics of AE signals emitted from concrete structures subjected to various environmental conditions are poorly identified. Therefore, this study examines the AE characteristics of the concrete structures during uniaxial compression, where the storage temperature and immersion conditions of the concrete specimens varied from 15℃ to 75℃ and from completely dry to water-immersion, respectively. Compared with the dry specimens, the water-immersed specimens exhibited significantly reduced uniaxial compressive strengths by approximately 26%, total AE energy by approximately 90%, and max RA value by approximately 70%. As the treatment temperature increased, the strength and AE parameters, such as AE count, AE energy, and RA value, of the dry specimens increased; however, the temperature effect was only minimal for the immersed specimens. This study suggests that the AE technique can capture the mechanical damage evolution of concrete materials, but their AE characteristics can vary with respect to the storage conditions.
        4,000원
        20.
        2022.05 구독 인증기관·개인회원 무료
        Source localization technique using acoustic emission (AE) has been widely used to track the accurate location of the damaged structure. The principle of localization is based on signal velocity and the time difference of arrival (TDOF) obtained from different signals for the specific source. However, signal velocity changes depending on the frequency domain of signals. In addition, the TDOF is dependent on the signal threshold which affects the prediction accuracy. In this study, a convolutional neural network (CNN)-based approach is used to overcome the existing problem. The concrete block corresponding to 1.3×1.3×1.3 m size is prepared according to the mixing ratio of Wolseong low-to-intermediate level radioactive waste disposal concrete materials. The source is excited using an impact hammer, and signals were acquired through eight AE sensors attached to the concrete block and a multi-channel AE measurement system. The different signals for a specific source are time-synchronized to obtain TDOF information and are transformed into a time-frequency domain using continuous wavelet transform (CWT) for consideration of various frequencies. The developed CNN model is compared with the conventional TDOF-based method using the testing dataset. The result suggests that the CNN-based method can contribute to the improvement of localization performance.
        1 2