검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2015.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Branch duct intraductal papillary mucinous neoplasms of the pancreas (BD-IPMN) without malignant features rarely developed into invasive cancer. However, invasive cancer is aggressive once an invasive change occurs. We report three cases of invasive cancers which developed in patients with BD-IPMN and they showed grave clinical courses. All patients were diagnosed with BD-IPMN < 3 cm without malignant features on imaging. Invasive cancer was detected at 2.5 years, 3.0 years, and 4.0 years after BD-IPMN detection in each patient. The intervals of invasive cancer and the last follow-up were 9 months, 3 years, and 1.5 years in the three patients, respectively. All patients were diagnosed with locally advanced pancreas invasive cancers and were treated with palliative chemotherapy or conservative management. The patients died at 3 months, 9 months, and 10 months after the diagnosis of invasive cancers, respectively. We report three cases of invasive cancer developed in BD-IPMN patients and followed fatal courses.
        4,000원
        2.
        2001.06 KCI 등재 서비스 종료(열람 제한)
        전파통신의 수요의 증가 및 통신시스템의 발달과 더불어, 인접 국가간의 전파간섭은 중요한 문제로 부각되고 있다. 이러한 문제는 외교적으로 미묘한 것이므로 명확한 기술적 근거를 가지고 대처해야한다. 우리나라의 경우, 일본후쿠오카에 위치한 기지국에 의한 남해안 TRS 서비스에 전파간섭이 발생한 후, 인접국가간의 전파간섭 문제가 중요하게 부각되었다. 따라서, 본 논문에서는 일본 후쿠오카에서 한국 부산으로 유입되는 전파를 실시간으로 측정하였다.
        3.
        1996.06 KCI 등재 서비스 종료(열람 제한)
        The method of Electromagnetic Wave Immunity Test is continuously endeavored by IEC and CISPR as international unification, but it has not been established yet. The main reason is why it is difficult to obtain the measurement method and normalization of threshold to find out the complicated parameters for Electromagnetic Wave immunity Test. So far, thus, the Electromagnetic Wave Immunity Test is carried out case by case as the electromagnetic environment, which is set up Electromagnetic Wave Immunity Test. This study has developed an algorithm and measurement software suitable for IEC1000-4 Regulations, where a ready-made Amplifier, and Signal Generator have been used and an interconnecting Interface Board has been constructed for connecting with the other apparatuses, i.e., RF Switch, Power Meter, Field Sensor, Pre-Amp., etc. Therefore, we have achieved the aim to develop an automated software using OOP method and the measurement system.
        4.
        1995.08 KCI 등재 서비스 종료(열람 제한)
        IEC and CISPR have continuously endeavored the measurement method of Immunity Test as international unification, but not established yet. The main reason is that the measurement method and the normalization of threshold to obtain the complicated parameters for Immunity Test are difficult. Thus, the Immunity Test Setups are used differently according to the measured electromagnetic environments. This study developed an Immunity Test System and Algorithm for measurement software suitable for IEC801-3 Regulatons using ready-made amplifier, signal generator, and developes interconnecting interface board interacting with other appratus i.e., RF Switch, Power Meter, Field Sensor and Pre-amp. We are to develope an automated software using Top/Down and OOP(Object Oriented Programming) method.
        5.
        1995.05 KCI 등재 서비스 종료(열람 제한)
        Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( Cy type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.