검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 7

        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To ensure the safety and functionality of a railroad bridge, maintaining the integrity of the bridge via continuous structural health monitoring is important. However, most structural integrity monitoring methods proposed to date are based on modal responses which require the extracting process and have limited availability. In this paper, the applicability of the existing damage identification method based on free-vibration reponses to time-domain deflection shapes due to moving train load is investigated. Since the proposed method directly utilizes the time-domain responses of the structure due to the moving vehicles, the extracting process for modal responses can be avoided, and the applicability of structural health evaluation can be enhanced. The feasibility of the presented method is verified via a numerical example of a simple plate girder bridge.
        4,000원
        2.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/ overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.
        4,000원
        3.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.
        4,000원
        5.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.
        4,000원
        6.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Korean Volunteer Fire Departments are the representative disaster-related civilian organizations which are based on "Firefighting Framework Act Article 37"and ordinance for complementing the lack of fire-fighting personnel and volunteer and they play a part as community safety keepers. They are operated by the National funding, but cannot be defined as the organization in governmental sources completely or pure volunteer organization in terms of its founding purpose and activities. In these special characteristics, some Volunteer Fire Departments play an important role in Civilian Volunteer Disaster Prevention by being managed effectively, but the others do not. There can be many cause-analyses about this difference. They aren't profit-making organizations and are groups which have no compulsion. So it is important that who the leader is, and what type of leadership he has. By solving this bias by considering these characteristics, in this study we make them perform the center role of community safety network through analyzing the existing status and problems of volunteer fire department education and customized training program reengineering to meet class-specific and regional level.
        4,000원
        7.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.
        4,000원