        Usually, bacterial spores are hundreds or thousands of times more resistant to chemical sanitizers than are vegetable bacteria. Consequently, it is hard to assess whether a commercial sterilant, containing hydrogen peroxide and peracetic acid as ingredients, has or does not have sporicidal activity under certain conditions using the National Standard Test Method for assessing bactericidal activity against Escherichia coli and Staphylococcus aureus. Hence we established alternative the standard test method and requirements to determine whether they are effective in showing at least reduction of 103 in the number of Bacillus subtilis ATCC 6633 spores under the required test condition for evaluation of sporicidal activity including verification methodology. This standardized method has proved to be suitable for evaluating effectiveness of commercial sterilants and could be used as Standardization Test Method for assessing sporicidal activity.
        4,000원
        2.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재 미국 및 유럽에서 공정시험법중 하나로 인정되고 있는 표면시험법을 사용하여 유기물과 함께 또는 유기물없이 세균만 건조된 식품접촉 표면에 서의 살균소독제 유효성에 대한 정보를 제공하고자 식품접촉표면으로 사용되는 스테인리스, 폴리프로필렌 및 실리콘에 Escherochia coli ATCC 10536 또는 Staphylococcus aureus ATCC 6538을 접종하고 살균소독제로서 염화벤잘코늄, 차아염소산나트륨 또는 에탄올을 20 ℃에서 5분간 처리하였다. 그 결과, 각 표면의 종류는 살균소독제의 유효성에 큰 영향을 미치지 않았으며, 200 ppm 농도의 염화벤잘코늄 및 차아염소산나트륨은 유기물질이 존재할 경우 생균수를 4 cfu log10/carrier 이상 감소시키지 못하였으나, 40% 에탄올은 생균수를 4 cfu log10/carrier 이상 감소시키는 것으로 나타났다.