검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to analyze the reproduction and breeding status of 1655 Hanwoo (Korean cattle) cows raised in Gangwon East area (Gangneung, Taebaek, Donghae, Yangyang, Samcheok, Sokcho, and Goseong). The average age in months and the parity of Hanwoo was 43.6 and 1.7 respectively. Registration status of the cows were 42.0% (pedigree), 30.2% advanced), 20.0% (fundamental), and 4.0% (non-registry). Korean proven bull's number (KPN) 517 and KPN 588 were preferred 25.8%, 16.2% respectively for artificial insemination (AI) of the cows. Appearance rate of over 1st meat quality grade in the offsprings obtained from AI of top 6 KPNs was 90% which was above national average (slaughters only 77.81%, total 63.12). Results indicated genetic influence the KPN for meat quality grade of their offspring. Strong correleation between AI failure rate of mother cows and their offspring cows has been observed. KPN information, meat quality grade, and AI failure percentage would be quite useful factors to understand their relationship in further improvement of Hanwoo in Gangwon East area.
        4,000원
        2.
        2005.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Electromagnetic fields of all frequencies represent one of the most common and fastest growing environmental influences, about which anxiety and speculation are spreading. All populations are now exposed to varying degrees of electromagnetic field, and the levels will continue to increase as technology advances. The objectives of this study were to measure and analyze emitting characteristics of extremely low frequency electromagnetic field at micro-environments. We measured magnetic field at microenvironments such as home, school, educational institute, internet pc game room for children attending the primary school. The range of time weighted average (TWA) of 60 Hz EMF in micro-environment were 0.26∼ 7.62 mG and the highest TWA 7.62 mG was measured in PC room possessed more than 50 computers. We will measure personal exposure levels of primary students and analyze correlation between major micro-environments and personal exposure level.
        4,200원
        3.
        2011.12 KCI 등재 서비스 종료(열람 제한)
        TE를 변화시킨 정상인 대뇌의 MR spectrum에서 주요 대사물질의 면적과 SNR을 측정하여 PRESS 펄스파형과 STEAM 펄스파형 그리고 1.5T와 3.0T간의 자장세기에 따른 spectrum 간의 차이를 알아보고자 하였다. Phantom 실험을 통하여 적절한 TR을 정한 후, 정상인 지원자 10명(3.0T 5명, 1.5T 5명 ; 남 22~30세 : 평균 26세 )을 대상으로 단일용적기법의 STEAM과 PRESS 기법을 시행하였다. 사용된 장비는 3.0T MR scanner(Magnetom Trio, SIEMENS, Germany)와 1.5T MR scanner(Signa Twinspeed GE, USA)이였다. 영상변수는 TR은 2000ms, TE 는 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA는 96, 용적 크기는 20×20×20mm3로 하였으며, spectrum 획득시간은 3분 20초였다. 획득한 데이터는 후처리과정을 통하여 PRESS와 STEAM, 그리고 1.5T와 3.0T system 간 의 NAA, Cho, Cr 등의 단순면적값과 SNR을 비교하였다. 또한 육안적 관찰을 통하여 각 대사물질들의 관찰정도를 비 교하였다.. 1.5T와 3.0T MR spectrum을 분석한 결과, STEAM과 PRESS의 주요 대사물질의 단순 면적값과 SNR은 TE가 증 가함에 따라 감소하는 경향을 보였으며, PRESS는 STEAM보다 1.5T에서 1.4배, 3.0T에서 1.3배 높은 SNR을 보였다. 자장의 세기에 따른 SNR 비교에서는 TE가 30ms에서 3.0T가 1.5T보다 약 2배 정도 높은 SNR을 보였으나 TE값이 증가함에 따라 3.0T에서의 SNR 감소율이 1.5T에서의 SNR 감소율보다 커서 TE가 90ms 이상부터는 큰 차이가 없었 다. 반면 3.0T의 spectrum에서는 1.5T에서 구분할 수 없었던 α-Glx, β․γ-Glx, NAA complex등 작은 대사물질들을 보다 정확히 감별 할 수 있었고 short TE의 PRESS일 때 short TE의 STEAM보다 작은 대사물질들이 잘 관찰 되었다. 3.0T spectrum의 해상도와 SNR이 1.5T spectrum에 비하여 우수함을 알 수 있었다. 그러나 90ms이상의 long TE 에서는 3.0T와 1.5T spectrum간의 SNR은 차이가 없었다. 따라서 고자장하에서의 자기공명분광법은 30ms 이하의 짧 은 TE를 이용한 PRESS 펄스 파형을 사용하는 것이 임상적으로 유용하게 사용될 수 있을 것이라 사료된다.