Background: To evaluate whether extracorporeal shock wave therapy (ESWT) in the pain point is a more effective treatment than the trigger point for myofascial pain syndrome (MPS) of the upper trapezius.
Objects: The purpose of this study was to compare the most effective areas when applying extracorporeal shock wave therapy.
Methods: A total of 30 patients with MPS were randomly assigned to the trigger point in the ESWT (n = 15) and pain point ESWT (n = 15) groups. Interventions in both groups were performed in one session, i.e., 2,000 shocks with 1.5 bar intensity. Pain and function were assessed using the visual analog scale (VAS) and cervical range of motion (ROM) and based on mechanical muscle properties. Statistical analysis was performed using the repeated measures two-way analysis of variance to determine the significance probability between pre- and post-test.
Results: Changes in mechanical muscle properties were not statistically significant between the two groups. However, VAS and cervical ROM showed statistically significant differences at pre- and post-intervention, regardless of the group (p < 0.05).
Conclusion: Although no significant difference was observed in the intervention effect, applying an extracorporeal shock wave to the pain point rather than the pain trigger point should be considered in order to save time in effectively and accurately identifying the pain trigger point and site.
In this paper, we describe the proposed KVN (Korean VLBI Network) clock system in order to make the observation of the VLBI effectively. In general, the GPS system is widely used for the time information in the single dish observation. In the case of VLBI observation, a very high precise frequency standard is needed to perform the observation in accordance with the observation frequency using the radio telescope with over 100km distance. The objective of the high precise clock system is to insert the time-tagging information to the observed data and to synchronize it with the same clock in overall equipments which used in station. The AHM (Active Hydrogen Maser) and clock system are basically used as a frequency standard equipments at VLBI station. This system is also adopted in KVN. The proposed KVN clock system at each station consists of the AHM, GPS time comparator, standard clock system, time distributor, and frequency standard distributor. The basic experiments were performed to check the AHM system specification and to verify the effectiveness of implemented KVN clock system. In this paper, we briefly introduce the KVN clock system configuration and experimental results.
In this paper, we describe the radio astronomical data processing system implementation using Mark5B and its development. KASI(Korea Astronomy and Space Science Institute) is constructing the KVN (Korean VLBI Network) until the end of 2007, which is the first VLBI(Very Long Baseline Interferometery) facility in Korea and dedicated for the mm-wave VLBI observation. KVN will adopt the DAS (Data Acquisition System) consisting of digital filter with various function and 1Gsps high-speed sampler to digitize the radio astronomical data for analyzing on the digital filter system. And the analyzed data will be recorded to recorder up to 1Gbps data rates. To test this, we have implemented the system which is able to process 1Gbps data rates and carried out the data recording experiment.
Ankle-foot orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of ankle muscular activities was developed. In this study, the effectiveness of the system was investigated during plantarflexion motion of ankle joint. To find a effectiveness of the system, the subjects performed maximal voluntary isokinetic plantarflexion contraction on a Biodex-dynamometer. Plantarfexion torque of the ankle joint is assisted by subject’s soleus muscle that is generated when ankle joint do plantarflexion motion. We used the muscular stiffness signal of a soleus muscle for feedback control of ankle-foot orthosis as physiological signal. For measurement of this signal, we made the muscular stiffness force sensor. We compared a muscular stiffness force of a soleus muscle between with feedback control and without it and a maximal plantarflexion torque between not wearing a ankle-foot orthosis, without feedback control wearing it and with feedback control wearing it in each ten elderly adults. The experimental result showed that a muscular stiffness force of a soleus muscle with feedback control was reduced and plantarflexion torque of an ankle joint only wearing ankle-foot orthosis was reduced but a plantarflexion torque with feedback control was increased.The amount of a increasing with feedback control is more higher than the amount of a decreasing only wearing it. Therefore, we confirmed the effectiveness of the developed ankle-foot orthosis with feedback control.
충북 청주시에 위치한 충북대학교에서 강수에 따른 습성강하물 중의 TN, TP 및 COD의 농도와 오염부하를 조사하였다 강수사상에 대한 샘플은 1998년에서 2003년까지 채집되었다. 오염물질의 강수량가중평균 농도는 TN이 0.60mg/L, TP가 0.014mg/L, COD는 4.8mg/L이었는데, 이는 각각의 산술평균보다 26, 18, 14% 작게 나타났다. TN, TP 및 COD의 농도는 강수량이 증가함에 따라 감소하는 경향을 나타냈다. 모든 수질항목
The incidence of aseptic meningitis infection is ensuing and threatening the health of children. Enteroviruses are the major agents of aseptic meningitis and identification of virus has been a clue to diagnosis and epidemiology. The outbreak of aseptic meningitis occurred in Pusan, 1998. Patients were concentrated from April through November. Children were more susceptible than adults. Among 306 cases of specimens from stool, throat swab tested, only 7.2% were positive on virus isolation, 12 cases from stool and 10 from throat, respectively. All isolated 7 serotypes of viruses represented cytopathic effect on cultured cells. Three types of echovirus 6, 25, 30 and coxsackievirus B2, B3, B4, B6 were identified by neutralizing antibody test. Isolated coxsackievirus and echovirus were observed by an electron microscope with negative staining.