검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to evaluate the quality of indoor air due to the remodeling and newly-built in S City, 60 schools wereinvestigated in formaldehyde (HCHO) and total volatile organic compounds (TVOCs). One school exceeded thenational standard of formaldehyde 100µg/m³ at 1st measurement. Thirty-eight schools showed higher level ofTVOCs over 400µg/m³ at 1st measurement. Twelve schools showed higher level of TVOCs over 400µg/m³ at2nd measurement. This result derived from TVOCs which originated from the building materials and finishingmaterials. To prevent the pollution of indoor air quality at schools caused by formaldehyde and TVOCs, therecommendation of environmentally-friendly building materials, the diminishment of emission by bakeout process,the efficient combination of natural ventilation and mechanical ventilation, and antibacterial effect of chemicalcontrol measures as photo-catalysts should be given positive investigation.
        4,000원
        2.
        2013.10 구독 인증기관 무료, 개인회원 유료
        The multi-tactile stimulation system was developed to analyze cognitive function characteristics. The developed system consists of three units; control unit, drive unit and actuator that simultaneously and separately supports the vibration, heat, and pressure stimulation. From the results, vibration stimuli have a wide frequency range of 0-300 Hz comprising 20 levels, and stimulation intensity comprising 40 levels. The control temperature and stimulation temperature used for heat stimulation comprise four and eight levels, respectively. Pressure stimuli in the range of 0-600 mmHg can be stimulated comprising 12 levels. Therefore, the developed stimulator can be used for integrative tactile perception and cognition studies on various vibration, heat and pressure sensations.
        3,000원
        3.
        2013.10 구독 인증기관 무료, 개인회원 유료
        In this paper, we developed a power amplifier system for driving a solenoid coil. The developed system consists of three units; control unit, drive unit and coil. The control unit generates a drive signal of sinusoidal wave type, monitors an operating status of the drive unit and vibration characteristics of the coil. The drive unit drives a solenoid coil in response to command from the control unit. The coil was fabricated with the size of diameter in 1.5 cm and length in 1.7 cm using electric copper wire. 4 types of drive unit were tested with thermal and vibration characteristics of the coil using temperature sensor and 3-axis accelerometer, respectively. From the result, the developed system has many advantages with respect to simple control algorithm, small size, and operates stably up to 68 watts driving condition.
        3,000원
        4.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate that the evaluation of odor analysis is affected by the classification of the agency and the general properties of the odor analysts, including gender, age, smoking behaviour, the number of participation in odor assessment, etc, so as to improve reliability and skills in terms of the result of complex odors by the air dilution methods. The sample for complex odor used the field sample which aimed at the odor analysts in the agency. The general characterizations of the odor analysts have affected the results of the odor analysis. The values of odor evaluation obtained by female odor analysts were more delicate than male, and the value of the result was reduced when above 40 s analysts conducted the evaluation. Moreover, Non-smokers perceived odor more sensitive than smokers. The more experience of odor analysis odor analysts had, The less values of the result were assessed. On the other hand, there are no differences in the value of odor evaluation depending on theclassification of institutions that participate in odor investigation. In conclusion, the selection of odor analysts considered gender, age, smoking behavior, and experience may be required to determine the improved reliability of data in odor evaluation. Ideally, Non-smokers 20~40 years old who have no dysfunction for the olfactory sense can be suitable for being optimal odor analyst.
        4,000원