검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Outdoor air pollution with particulate matter has become more severe in Korea. Ambient particle concentration affects the indoor environment through various routes through building envelopes. In this study, we investigated particle exposure in residential buildings. Indoor and outdoor particle sources determined the indoor concentrations and particle exposure. This paper measured indoor particles and CO2 concentrations in two different apartment buildings and conducted the survey for 24 hours. The I/O ratio of the occupant awake period was higher than the asleep period. The I/O ratio in the awake period is 0.93-3.65, while the I/O ratio in the asleep period is 0.31- 0.76.Indoor peak events such as cooking or cleaning temporarily increase the I/O ratio and emit the indoor particle sources. Decay rate constant is 0.49-6.84 (1/h) in the indoor peak events during the operation of the exhaust hood and natural ventilation. The size range of 0.3-0.5 μm size is over half for the proportions of emitted particles (55.6%). Daily exposure is divided into indoor sources (45.2%) and outdoor sources (54.8%). We found the differences for the proportion of particle exposure. The ratio of daily exposure in particles for 0.3-0.5 μm size is 43.1 (indoor)/ 56.9 (outdoor) %. However, indoor sources are higher than outdoor sources for the ratio of daily exposure in particles for the 0.5-10.0 μm size.
        4,000원