검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 27

        21.
        2018.10 서비스 종료(열람 제한)
        Acoustic Emission (AE) technique applied to detect the crack occurrence of the actual beam element. An optimum position for a limited number of AE transducer was considered to accurately detect the location of the cracks in the three-dimensional space. Six AE transducer was used to detect cracks in the L400mm×H200mm×T100mm region, and several position combinations were applied. Considerable six position combinations were selected, and the weak or incorrect position detection was investigated. The optimum position applied to the experiment for actual beam element and the detected crack position was compared with the visual inspection location. A reliable crack position detecting was confirmed for loadings.
        22.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        대표적인 저강도 초음파 자극 기술인 음파영동은 초음파의 물리적 진동과 온열 효과를 이용하여 약물을 인체 표피 내부로 전달시키는 기법이다. 음파영동법은 치료 약물 전달의 효율을 높일 수 있으며, 인슐린이나 지질 등 분자 크기가 비교적 큰 약물의 전달에도 효과적이라는 장점을 갖는다. 본 연구에서는 효율적인 음파영동 치료를 위하여 대면적 단일 진동소자와 치료 부위에 약물 이송 기능을 갖는 복합 구조 초음파 변 환기 어셈블리를 제안하였다. 또한, 치료 부위의 온도를 상승 및 유지시킬 수 있는 변환기 어셈블리 구조를 제안하고 유효성을 평가하였다. 본 연구에서 제안된 변환기 어셈블리는 지속적으로 정량의 약물을 제공하고, 가온을 통하여 약물 전달을 보조함으로써 초음파를 이용한 음파영동 시술의 효율을 향상시킬 수 있을 것으로 사료된다.
        23.
        2013.12 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        A W-band Orthomode Transducer (OMT) has been developed for Korean VLBI Network (KVN) polarization observation. The OMT design was based on E-plane split-block technique using septum structure. 3-dimensional electromagnetic simulation was fully employed to optimize the performance of the OMT. Measurements of the fabricated OMT show that the return losses for the vertically and horizontally polarized modes are better than -20 dB across 80 ~ 108 GHz and the insertion losses for the both modes are less than 0.47 dB. The cross-polarization level of the OMT is less than -30 dB. The bandwidth of the developed OMT is estimated as around 30%.
        26.
        1981.12 KCI 등재 서비스 종료(열람 제한)
        A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.
        27.
        1980.11 KCI 등재 서비스 종료(열람 제한)
        Computer simulation results on the radiation pattern of an ultrasonic beam by the plurall arrangement of the transducers were reported by Sin (1979). This paper describes on the measurement of radiation pattern in case of one vibrox transducer and two vibrox transducers by varying the interval between the transducers. The measured results obtained are as follows; 1. Radiation wave of ultrasonic transducer is propagated to diffuse with spherical wave from center of transducer. 2. In case of one vibrox transducer, the greater the length of transducer, the sharper becomes the radiation pattern. 3. In case of two vibrox transducers, the maine lobe is revealed at the center of two transducers, it is shown difficult to make control freely of radiation pattern by varying merely the interval of transducers.
        1 2