It is effective to apply hybrid damping device that combine separate damping device to cope with various seismic load. In this study, HRS hybrid damper(hybrid rubber slit damper) in which high damping rubber and steel slit plate are combined in parallel was proposed and structural performance tests were performed to review the suitability for seismic performance. Cyclic Loading tests were performed in accordance with criteria presented in KDS 41 17 00 and MOE 2019. As a result of the test, the criteria of KDS 41 17 00 and MOE2019 was satisfied, and the amount of energy dissipation increased due to the shear deformation of the high-damping rubber at low displacement. Result of performing the RC frame test, the allowable story drift ratio was satisfied, and the amount of energy dissipation increased in the reinforced specimen compared to the non-reinforced specimen.
바람에 의한 구조물의 진동은 관심대상이 되는 지배모드의 감쇠비에 매우 민감하다. 감쇠비의 발현 메커니즘의 불확실성 등 에 의해 감쇠비의 추정은 여전히 도전과제이며 보다 정확한 감쇠비 추정을 위한 연구가 지속되고 있다. 본 연구에서는 스펙트럼 밀도 적분함수라는 새로운 개념을 이용하여 구조물의 감쇠비를 추정하는 기법을 다룬다. 모드 응답스펙트럼에 포함된 외부하중 스펙트럼을 적분에 의한 평균화효과에 의해 평탄화 한 후 이론적 적분함수와 비교하여 감쇠비를 구하는 원리이다. 감쇠비 추출 가능성 탐색을 위 해 이론적 스펙트럼 밀도 적분함수의 특성을 분석하였으며, 비고전감쇠 시스템이 가지는 혼성 모드응답에 적용할 수 있는 감쇠비 추 정법로 확장하였다. 본 연구에서 제안된 감쇠비 추정법을 검증하기 위한 수치해석과 계측응답에 대한 적용이 이루어졌으며, 검증결과 제안된 감쇠비 추정법이 안정적이며, 신뢰도가 높은 감쇠비 추정이 가능함을 알 수 있었다.
본 논문는 개폐식 대공간 구조물의 지진하중에 대한 동적응답을 줄이기 위한 목적으로 파라메트릭 설계 기법을 적용한 TMD에 관한 연구이다. 인공지능 알고리즘을 이용하여 감쇠장치의 설치 위치를 자동 탐색하는 컴포넌트를 개발하였다. 이는 구조물의 동적응답을 실시간으로 확인하고, 구조물의 감쇠장치 최적의 위치를 찾을 수 있을 있다. 또한, 여러 대안에 대한 감쇠장치 질량의 최적 값을 찾아주며, 지붕의 열린 상태와 닫힌 상태에 모두 효과적으로 적용될 수 있는 설계안을 찾을 수 있다.
풍방향 공력감쇠는 항상 정감쇠 형태로 나타나기 때문에 구조물 진동을 더욱 안정화하는 경향이 있다. 준정상 가정에 의하여 공력감쇠를 예측할 수 있는 이론적 모델은 풍방향 공력감쇠의 발현특성을 모사하고, 발현에 영향을 미치는 영향인자를 설명하고 있다. 본 연구에서는 공탄성 실험을 통해 얻어진 계측응답으로부터 추정된 풍방향 감쇠를 이론적 풍방향감쇠와 비교하여 준정상 가정으 로부터 구해진 이론적 모델의 정합성을 평가하였다. 풍방향 감쇠는 최신 개발된 시스템 식별기술인 가상동적가진기에 의한 방법을 이 용하여 구한다. 본 연구결과로부터 풍방향 공력감쇠는 준정상가정에 의한 이론적 모델과의 차이를 보이며, 이것은 주로 높이별, 평균 풍속에 따른 난류강도의 크기에 의하여 영향을 받는 것으로 나타났다.
The present study is aimed to calculate the optimal damping according to the seismic load on the structure with a non-seismic design to perform structure analysis considering the deformation of structural joint connection and panel zone; to develop design program equipped with structural stability of the steel frame structures reinforced with the panel zone and viscous dampers, using the results of the analysis, in order to systematically integrate the seismic reinforcement of the non-seismic structures and the analysis and design of steel frame structures. The study results are as follows: When considering the deformation of the panel zone, the deformation has been reduced up to thickness of the panel double plate below twice the flange thickness, which indicates the effect of the double plate thickness on the panel zone, but the deformation showed uniform convergence when the ration is more than twice. The SMRPF system that was applied to this study determines the damping force and displacement by considering the panel zone to the joint connection and calculating the shear each floor for the seismic load at the same time. The result indicates that the competence of the damper is predictable that can secure seismic performance for the structures with non-seismic design without changing the cross-section of the members.
In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.
공력감쇠는 와류에 의한 풍직각방향의 응답을 평가하는데 매우 유용한 인자로 인식되어 왔다. 그러나 기존의 공력감쇠 산정 방식은 구조물 응답에 기반한 시스템 식별기술을 적용하는 것으로 와류하중속에 포함되어 있는 공력감쇠의 역할과 특성을 파악하는 데 한계를 가지고 있었다. 본 연구에서는 하중식별기술을 적용하여 와류하중을 직접적으로 구함으로써 와류하중을 구성하는 요소와 유발요인을 평가하고자 하였다. 이를 위하여 대기 경계층에서 원형 실린더 모델에 대한 공탄성 실험을 수행하여 풍직각방향 와류하중 을 추정하였으며 그로부터 공력감쇠의 특성을 분석하였다. 분석결과, 와류하중은 구조물 모달속도가 공력감쇠에 의해 풍하중으로 전 환되는 모달속도하중과 변동풍속에 의해 형성되는 순수 와류하중으로 구성되는 것으로 나타났다. 공력감쇠는 최상층 평균풍속에 의한 와류방출진동수가 구조물의 고유진동수에 근접하면서 부감쇠를 가지며 그 결과 총 감쇠가 작아져 응답증폭현상을 유발하는 것으로 파악되었다. 본 연구결과에 기초하면, 난류상태에서 와류하중 특성이 반영된 와류하중모델 구축이 가능할 것으로 사료되며, 구조물 풍직 각방향 진동을 보다 효과적으로 파악하는데 활용될 수 있을 것으로 사료된다.
경량한 세장 구조물의 내풍안정성을 향상시키기 위하여 다양한 제진장치가 사용되어 왔다. 제진장치에 의하여 구조물에 부가되는 감쇠는 기존의 질량, 강성에 비례하는 고전감쇠와 달리 비고전 특성을 가진다. 비고전 감쇠는 복소의 모달 특성을 보유하기 때문에 해석과 평가과정에서 모드의 거동을 파악하기 어렵다. 이러한 이유 때문에 복소 모달 변수를 실수로 변경하기 위한 방법이 요구 되며, 변경된 실수 모달 특성이 가지는 물리적 의미를 고찰할 필요가 있다. 본 연구에서는 상태공간에서 비고전 감쇠시스템의 복소 모달 변수를 실수 모달 변수로 변경하는 과정을 소개하고 그 모달변수가 가지는 특성을 분석함으로써 비고전 감쇠를 가지는 구조물의 해석 및 평가가 보다 명쾌한 물리적 의미를 가지고 이루어질 수 있도록 하였다. 또한 비고전 감쇠구조물의 계측응답만으로 실수의 모달 특성을 추정할 수 있는 상태공간 기반 모드분해 기법에 대해서 다루고 그 특성을 비교 검증하였다. 본 연구에서 제시된 기법을 카고메 트러스 댐퍼가 설치된 비고전 감쇠 구조물에 적용하여 수치적으로 검증하였으며, 수치해석 결과로부터 복소 모드형상이 실수공간으로의 변환이 가능하며, 그 실수 모드형상이 계측응답만으로도 추정 가능함을 알 수 있었다.
구조물의 감쇠비는 내풍성능을 평가하는 가장 중요한 요소 중의 하나이다. 구조물의 실제 감쇠비는 대부분 계측된 응답을 기반으로 시스템 식별기술에 의하여 이루어진다. 그러나 예측된 감쇠비는 계측조건, 계측시간 및 시스템 식별기술에 따라 오차를 보이는 등 불확실성을 가지고 있다. 본 연구에서는 기 개발된 가상 동적진동기(Virtual Dynamic shaker)에 주요 개념으로 사용되었던 외부하중 스펙트럼의 전체 평탄성을 국부 평탄성으로 개념을 확대하여 감쇠비 추정을 보다 정교하게 하는 기법을 개발하였다. 국부 평탄성을 개념을 사용하여 감쇠비를 구하고자 하는 대상 모드의 고유진동수 부근에 적용함으로서 보다 정확하게 감쇠비 추정하는 기법을 다루었다. 본 개발된 기법을 검증하기 위하여 고층건물의 상시진동에 대하여 적용하였으며, 기존 시스템 식별법, 자유진동실험에 의한 결과와 비교 평가하였다. 그 결과 전체 평탄성을 가지는 개념에 비하여 국부평탄성을 가지는 VDS가 보다 정확하게 감쇠비를 추정하는 것을 보였다.
구조물의 성능을 개선하기 위하여 다양한 진동제어장치가 사용되고 있다. 대부분의 제진장치는 구조물의 감쇠비를 증가시킴으로써 성능개선효과를 유도하기 때문에 증가된 감쇠비는 제진장치에 의한 구조물의 성능을 평가하는 중요한 지표가 될 수 있다. 본 연구에서는 강풍 등으로 제진장치가 운영 중인 상태에서 구조물의 응답만을 이용하여 각 모드에 증가된 등가감쇠비를 추정하는 프로세스를 개발하고 이를 성능개선효과를 평가하는데 활용하고자한다. 제진장치가 설치된 구조물은 비고전 감쇠시스템이므로 상태공간 모드분해법을 이용하여 계측응답으로부터 모드 응답을 구하고, 분해된 모드응답에 가상 동적 진동기를 적용하여 각 모드에 증가된 감 쇠비를 구하였다. 제안된 제진장치 설치 구조물 감쇠비 추정법을 검증하기 위하여 수동형 제진장치로 카고메 점탄성 댐퍼를, 능동형 제진장치로 능동질량감쇠기를 구조물에 적용하여 각 제진장치에 의한 감쇠비를 추정한 결과 매우 정교하게 예측 가능함을 알 수 있었다.
Wind tower structure has relatively simple shape compared to other structures, but due to its characteristics, various and irregular environmental loads are applied. These loads cause vibrations at tower, and can cause failure of the structure if over vibration occurs. Vibration occurred at structures is gradually exhausted by damping of the structures, and if high damping is ensured, the failure of the structure due to over vibration can be prevented. In this study, the vibration reduction effects are to be analyzed through FEM analysis by examining the top displacement, bottom moment, and bottom fatigue damage of the structure depending on damping ratio of the wind tower structure.
In this study, effectiveness of seismic retrofitting methods using passive damping devices was investigated through numerical analyses of short-period structures under earthquakes which have short-duration and high-frequency impulse characteristics similar to Geyongju earthquakes. Displacement spectra of elastic systems and ductility demand of inelastic systems were evaluated by increasing viscous or friction damping. The damping devices could reduce responses of the structures with shorter structural period than 0.2s. The earthquakes similar to impulse load did not induce the responses of the structures with longer period than 0.4s, and the effects of the damping devices which generates damping forces proportional to structural responses became insignificant.
The proposed hybrid damper installs at a coupling beam and consists of a high-damping rubber (HDR) and steel pin. The proposed hybrid damper adopted a pin-lock system acts as a viscoelastic damper under wind load (small displacement) while it behaves as a hysteretic damper under earthquake load (large displacement).
In this paper, the pin-lock mechanism and structural performance of the proposed hybrid damper is evaluated through experiment. Experiments were carried out with the variables which displacement, loading frequency and steel pin quantities were used. Test results showed that the pin-lock mechanism and the performance of the hybrid damper under a large displacement were verified. Also equivalent damping ratios of HDR were increasing at a small displacement as displacement amplitudes were increasing. However HDR did not depend on frequency,
본 연구는 가상 질량 동조기(VMT)를 이용하여 구조물의 응답으로부터 구조물의 감쇠비를 구하는 기법을 다룬다. 백색잡음 뿐만아니라, 특정 진동수 가진, 충격하중 가진 등 다양한 하중종류 및 특성에 의하여 발생한 구조물의 계측응답에 대하여 VMT를 적 용하였을 때 구조물의 감쇠비를 추정하는 기법에 대해서 다루고, VMT의 동적특성이 구조물 감쇠비 추정에 미치는 영향을 수치적으로 분석하였다. 수치해석결과에 의하면, VMT에 의하여 구조물 감쇠비 추정이 충분한 신뢰성을 가지고 예측되는 것을 확인 할 수 있었다. 충격하중을 받는 응답을 이용하는 경우 VMT에 의하여 가장 안정적으로 구조물 감쇠비 추정이 가능한 것을 알 수 있었으며, 백색잡음, 협소대역 하중에 대해서도 VMT의 지정 감쇠비를 너무 작게 산정하지 않으면 감쇠비 추정이 가능한 것으로 나타났다. 정현파의 경우에는 가진 진동수의 VMT 비율을 이용하여 감쇠비 추정이 가능한데 고유진동수와 인접할수록 정밀도가 높아지는 것을 알 수 있었다.
It has been many efforts for reinforcement of existing structure since the number of earthquake has been increased world widely. Especially the occurrence of earthquake surrounding area of Korean peninsular is dramatically increased. Since the buildings in Korea have not been designed to carry the lateral and shear force caused by earthquake, the building will experience massive damages even under moderate earthquake. For this reason, the viscoelastic damper is proposed in this paper to enhance the earthquake resistance of a steel frame buildings. The viscoelastic dampers have been able to increase the overall damping of the structure significantly, hence improving the overall performance of dynamically sensitive structures. In this paper, Viscoelastic dampers designed are consists of FRP panel and viscoelastic material. In this paper, evaluate the performance of the viscoelastic damper through the experiment.
본 연구에서는 파라매트릭 모델링 기법을 통해 다양한 대안을 고려할 수 있도록 개발된 StrAuto(이하 전산플랫폼)을 이용하여 감쇠장치에 따른 감쇠비 증가 효과와 풍하중 저감효과를 평가하였다. 비정형 초고층구조물의 수많은 구조시스템 대안선정을 지원하는 전산플랫폼은 설계자 또는 엔지니어에게 초기 대안을 결정하는데 있어 유용한 도구가 된다. 감쇠장치의 용량 및 추가 요구감쇠비의 크기를 산정하는 과정에서 중요한 원 구조물의 감쇠비에 대한 추정은 풍하중에 대한 실계측 자료를 기반으로 수행된 국내외 관련 연구의 결과를 사용하였다. 감쇠장치는 층간 설치형 수동형 감쇠장치와 질량형 능동형 감쇠장치 두 가지 유형을 고려하였다. 감쇠장치에 의해 추가되는 감쇠비는 FEMA에서 제안한 식을 이용하여 등가 정적 해석을 수행하여 산정하였다. 전산 플랫폼 내부에 감쇠장치의 용량을 최적화하는 알고리즘을 내장함으로써 최적의 감쇠장치 설계안을 자동적으로 도출할 수 있다. 감쇠장치 설치에 따른 물량저감 효과는 풍하중 저감계수로 평가될 수 있으며, 455m 높이의 초고층구조물을 대상으로 제안한 방법의 유효성을 검증하였다. 제안한 방법을 사용하여 비선형 시간이력 해석을 통해 얻어진 지붕층 변위와 층별 전단력을 근사적으로 추정할 수 있음을 확인하였다.
면진장치는 지진력을 감소시키기 위하여 사용되어왔다. 원자력발전소에 면진장치가 적용된다면, 운영기간동안 구조물과 기기들은 동일한 내구성 및 성능이 확보되어야 한다. 본 연구에서는 면진된 원전의 지진에 대한 안전성을 확보하기 위하여 면진구조물의 장기거동을 해석적으로 분석하였다. 경년열화에 의한 면진장치 특성을 분석하였고, 다른 온도환경에서 면진장치의 경년열화에 의한 구조물의 지진응답을 분석하였다. 해석결과에 의하면 면진장치의 경년열화에 의하여 면진구조물의 고유진동수는 증가하였다. 그러나 면진 구조물의 최대가속도와 최대변위는 온도에 따라 크게 변하지 않았다. 면진장치의 열화에 의하여 구조물의 손상은 발생하지 않았지만 목표진동수 영역에서 스펙트럼가속도는 온도에 따라 증가하였다. 따라서 면진구조물에서 면진장치는 온도에 따른 지진응답의 증가를 고려하여 설치 및 제작해야 할 것으로 판단된다.
본 연구에서는 풍응답 제어를 위해 능동질량감쇠기가 설치된 39층 구조물의 시스템식별을 수행하였다. 능동 질량감쇠기를 가진기로 이용하여 입력 조화하중 신호를 생성하여 구조물을 가진하였으며, 가진 결과로 발생한 구조물의 가속도 응답을 계측하여 구조물의 전달함수를 파악하였다. 대상 구조물의 상시진동 계측 결과를 바탕으로 가진 제어 대상이 되는 주요 저차모드의 개략적인 범위를 파악한 후 가진 진동수 대역을 결정하였으며, 3곳의 위치에서 계측된 가속도 응답을 바탕으로 제어대상 3개 모드의 진동수와 감쇠비, 그리고 모드형상을 식별하였다. 모드벡터는 AMD의 설치위치 및 가진방향과 동일한 위치의 응답을 기준으로 정규화하여 구성하였으며, 정규화된 모드벡터에 따른 모드 질량행렬을 도출하였다. 식별된 모드특성을 이용하여 구성된 해석모델을 사용하여 얻어진 가속도 응답이 계측된 결과와 거의 일치한다는 사실로부터 식별된 모델이 적절하게 구조물의 동적거동을 모사하고 있음을 확인하였다.
면진장치는 상부구조물의 지진력을 감소시키는데 크게 기여하지만, 고감쇠고무 적층받침에 사용되는 고무재료는 시간이 경과함에 따라 열화되어 상부구조물의 동특성과 기기들의 지진응답에 영향을 줄 수 있다. 따라서 면진장치의 경년열화를 고려한 구조물의 지진응답을 분석하는 연구가 필요하다. 본 연구에서는 기존 문헌을 통하여 분석된 고무의 경년열화 특성을 사용하여 면진장치를 모델링하였다. 면진된 원전의 지진응답을 평가하기 위하여 격납건물과 보조건물을 대상 구조물로 선정하고, 진동수 성분이 다양한 입력지진동을 사용하여 구조물의 고유진동수, 최대지진응답, 층응답스펙트럼을 시간의 경과에 따라 분석하였다. 해석결과에 의하면 면진장치의 경년열화에 의하여 지진응답이 소폭 증가하였으며, 면진장치가 설치된 후 20년까지 지진응답의 증가율이 크게 나타나므로 이 기간에 상세한 검사가 시행되어야 할 것이다.