In this study, chemically enhanced steam cleaning(CESC) was applied as a novel and efficient method for the control of organic and inorganic fouling in ceramic membrane filtration. The constant filtration regression model and the resistance in series model(RISM) were used to investigate the membrane fouling mechanisms. For total filtration, the coefficient of determination(R2) with an approximate value of 1 was obtained in the intermediate blocking model which is considered as the dominant contamination mechanism. In addition, most of the coefficient values showed similar values and this means that the complex fouling was formed during the filtration period. In the RISM, Rc/Rf increased about 4.37 times in chemically enhanced steam cleaning compared to physical backwashing, which implies that the internal fouling resistance was converted to cake layer resistance, so that the membrane fouling hardly to be removed by physical backwashing could be efficiently removed by chemically enhanced steam cleaning. The results of flux recovery rate showed that high-temperature steam may loosen the structure of the membrane cake layer due to the increase in diffusivity and solubility of chemicals and finally enhance the cleaning effect. As a consequence, it is expected that chemically enhanced steam cleaning can drastically improve the efficiency of membrane filtration process when the characteristics of the foulant are identified.
BSA 용액의 전량 한외여과에서 막모듈의 중력에 대한 경사각(0~180°) 변화에 따라 유발된 자연대류 불안정 흐름 (natural convection instability flow; NCIF)의 막오염 제어 효과를 플럭스 증가 정도로 측정하고 막힘여과 모델로 해석하였다. 막모듈의 경사각이 0°에서 180°로 커질수록 NCIF 유발이 증가하여 막오염 제어 효과가 커져 플럭스가 증가하였다. NCIF의 유발이 가장 큰 경사각 180°에서의 플럭스 값을 NCIF의 유발이 없는 0°에서의 값과 비교한 결과, 2시간의 단기간 운전에서는 플럭스 향상성이 5배, 20시간의 장기간 운전에서는 17배까지 증가하였다. 막힘여과 모델을 적용하여 NCIF의 유발에 따른 플럭스 증가 효과를 해석한 결과, 운전시간 15분 이내에서는 중간막힘 모델 그 이후에는 케이크여과 모델로 해석하는 것이 타당하였다. 막모듈 경사각 180°에서 유발된 NCIF는 15분 이내의 운전 초기에는 중간막힘 오염을 67%까지 감소시키고, 그 이후의 운전 시간에서는 케이크층 오염을 99.9%까지 감소시켰다. 따라서 막모듈에 유발된 NCIF의 주된 막오염 제어 기작은 케이크층 형성을 억제시키는 것이었다.
In this study, various physical cleaning methods such as physical washing and osmotic backwash, were conducted to understand membrane fouling properties by employing real secondary wastewater effluent (SWWE). In addition, microfiltration (MF) and ultrafiltration (UF) pretreatments were compared to maximize removal of organic matter and to control membrane fouling efficiently. Organic foulants deposited on the active layer of FO membrane were observed by fouling behavior test. The relationship between concentrations of natural organic matter and membrane fouling was also investigated from the bench-scale FO tests.
산업폐수 처리에서 미량오염물질(독성 유기물, 화합물, 연료 등)의 제거가 중요하다. 생물학적 처리에 의해서는 미량오염물질을 제거하기 어렵다. 따라서 본 연구에서는 분리막과 고도전기산화를 접목하여 색도, 미세입자등을 효과적으로 제거하고 막오염을 저감시키는 막결합형 고도전기산화시스템을 개발하였다. 색도는 원수 120 도(Pt-Co 색도 값)에서 처리수 20 도이하로 제거되었고, 탁도의 경우 처리수 0.1 NTU이하의 수준으로 감소하였다. 또한 막오염 저감의 성능으로 전극을 켜지않고 실험하였을때 16 kPa까지 증가하였으며 0.5 A/L전류를 공급하였을 때 5 kPa으로 유지되었다. 본 연구는 한국환경산업기술원의 환경융합 신기술 개발사업(No. 2015001640004) 연구결과의 일부이다.
A membrane module including grid was designed and introduced to MBR (membrane bio-reactor) for the purpose of better control of membrane fouling. It could be anticipated that the grid enhances the shear force of fluid-air mixture into the membrane surface by even-distributing the fluid-air to the membrane module. As MLSS concentration, packing density which is expressed in the ratio of the housing and the cross-sectional area of membrane fibers (Am/At) and air-flow rate were changed, membrane foulings were checked by monitoring fouling resistances. The total fouling resistance (Rc+Rf) without grid installation (i.e., control) was 2.13×1012 m-1 , whereas it was reduced to 1.69×1012 m-1 after the grid was installed. Regardless of the grid installation, the Rc+Rf increased as the packing density increased from 0.09 to 0.28, however, the increment of resistance for the grid installation was less than that of the control. Increase in the air flow rate did not always guarantee the reduction of fouling resistance, indicating that the higher air flow rate can partially de-flocculate the activated sludge flocs, which led to severer membrane fouling. Consequently, installation of grids inside the housing have brought a beneficial effect on membrane fouling and optimum air flow rate is important to keep the membrane lowering fouling.
Membrane bioreactors (MBRs) employ a process of biological treatment that is based on a membrane that has the advantages of producing high-quality treated water and possessing a compact footprint. However, despite these advantages, the occurrence of “fouling” during the operation of these reactors causes the difficulty of maintenance.Hence, in this study, three physical cleaning methods, namely, backwashing, air scrubbing, and mechanical cleaning ball was performed to identify optimum operating conditions through laboratory scale experiments, and apply them in a pilot plant. Further, the existing MBR process was compared with these methods, and the field applicability of a combination of these physical cleaning methods was investigated.Consequently, MCB, direct control of cake fouling on the membrane surface was found to be the most effective. Moreover, as a result of operating with combination of the physical cleaning process in a pilot plant, the TMP increasing rate was found to be – 0.00007 MPa/day, which was 185% higher than that obtained using the existing MBR process. Therefore, assuming fouling only by cake filtration, about one year of operation without chemical cleaning is considered to be feasible through the optimization of the physical cleaning methods.
본 연구에서는 소수성 PVDF막 표면에 중성 친수성 고분자인 Poly(vinyl alcohol) (PVA)를 코팅한 후 순수 투과도를 측정하고 대표적인 단백질 오염물질인 bovin serum albumin (BSA)에 대하여 파울링 실험을 수행하였다. BSA 용액 20ppm 조건에서 파울링 실험을 수행한 결과, 코팅 전 막에 비하여 순수 투과도는 감소하였지만 내오염성은 현저히 증가됨을 알 수 있었다. 코팅된 PVA의 분자량이 커질수록 순수 투과도는 감소하였으나, 내오염성이 증가하는 경향을 보였다. 또한, 코팅된 PVA의 농도가 높아질수록 순수 투과도는 감소하였고, 내오염성이 증가하였다. 이는 접촉각과 AFM 측정 결과와 관련하여 코팅 후 막 표면에 친수성의 증가와 거칠기가 감소했기 때문으로 여겨진다.
본 연구에서는 4종류의 탄소계 관형 세라믹막으포 제지공장의 방류수를 물로 주기적 역세척하면서 한외여과하였을 때, 물 역세척 주기와 막간압력차 (TMP), 유량의 영향과 최적운전조건을 규명하였다. 역세척 시간(BT)은 3초로 고정하였고, 역세척 주기(FT)는 여과시간을 15~60초로, TMP는 1.00~2.50kgf/cm2로, 유량은 0.25~1.75 L/min로 변화시켜 가면서 각각 그 영향을 살펴보았다. 또한, 최적조건은 무차원 투과선속 (J/JO) 및 총 여과부피 (VT), 막오염에 의한 저항 (Rf)의 측면에서 고찰하였다. 그 결과 최적 역세척 주기는 BT/FT=0.20로, 빈번한 역세척은 막오염을 감소시켰다. 한편, VT측면에서 최적 TMP는 1.00~1.55kgf/cm2로 TMP 증가는 막오염을 심화시켜 투과선속을 감소시켰으나, 유량 증가는 막오염을 감소시켜 투과선속을 증가시키는 경향을 보였다. 본 연구에서 사용한 탄소계 세라믹 분리막에 의한 오염물질 제거율은 탁도의 경우 88~98%로 높았으나, CODcr의 경우 48~72%, 총용존고형물 (TDS)의 경우 37~76%였다.