        검색결과 12

        1.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, a method for evaluating concrete bridge deck deterioration using three-dimensional (3D) ground penetrating radar (GPR) survey data and its in situ application are discussed. METHODS : Field surveys are conducted on two bridges in Yongsan-gu (Bridge A) and Seodaemun-gu (Bridge B) in Seoul using 3D GPR. The obtained survey data are used to calculate the dielectric constant map of each bridge using the extended common midpoint method. In addition, random points on both bridges are selected for the chloride content test in accordance with the KS F 2713 standard. The results from the dielectric constant map and chloride content test are compared. RESULTS : For Bridge A, it is discovered that the percentage of sections with a dielectric constant of 5.0 or less is 1.57%, whereas that above 5.0 is 98.43%; this indicates that the percentage of deteriorated sections for Bridge A is low. Meanwhile, for Bridge B, the dielectric constants calculated for the entire bridge exceed 5.0, which suggests no deterioration for Bridge B. Moreover, all the points selected for the chloride content test have less than 0.15% chloride content and have dielectric constants ranging from 5.0 to 7.0, which are favorable condition for the bridge deck. CONCLUSIONS : The analysis results of the dielectric constants of the concrete bridge deck obtained from the 3D GPR system are consistent with the actual chloride content results. Furthermore, additional verification of this method through field surveys on bridge sections with severe deterioration is highly recommended for future improvements.
        4,000원
        2.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Composite Floor system infilled with PCM(Phase Change Material) between upper and lower steel plates was developed to apply the steel frame. When steel frames were applied this system, it can absolutely reduce the duration of construction due to dry construction method. However to apply this system as a structural floor member without fire resistance covering, it must have 2 hours fire resistance performance. Because PCM consisted of three quarters of section with thermal insulation performance, fire resistance performance of this floor system was expected to easily have 2 hours fire resistance performance. This paper was to investigate behavior characteristics of PCM infilled floor system at elevated temperature using FEM analysis to develop the fire resistance performance of it.
        4,000원
        3.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerical models of composite floor systems with various thickness of phase change material and sizes of circular spacers were developed based on finite element analysis. In order to perform a heat transfer analysis, thermal properties of steels were determined and those of phase change material were estimated from experiment results. In addition, the thermal insulation performance of composite floor systems with respect to different thickness of phase change material and sizes of circular spacers was predicted. To verify the validity of analysis, analysis results were compared with vertical furnace fire test results of equivalent conditions. As a result, available thicknesses of phase change material and sizes of circular spacers were proposed to satisfy the thermal insulation criteria of Korean Standards.
        4,000원
        4.
        2012.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to examine the light weight impact sound insulation of dry type system in apartment house. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The measurement frequency level average of dry type system-on is more suitable than that of dry type system-off which are dependent on specific frequency for light-weight floor impact sound. 2) Level average for measurement frequency of 100∼セ500Hz is more correspondent to vibration-acoustic response than that of measurement frequency of 100∼!500Hz which is for KS F 2863-2, existing rating method.
        4,000원
        5.
        2011.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        A system has been developed to reduce fluctuation of the indoor temperature in a radiant floor heating system. The system we developed and implemented is called BoilerMan. With the BoilerMan system the hot water circulation pump is controlled by computer software which implements a unique strategy. To minimize the system development time a user-friendly development environment was used. This development environment was useful in the implementation and testing of the efficiency of our strategy. The environment also serves as an easy means for system maintenance. The BoilerMan went through a few test runs against a real apartment house and the result showed significant reductions in the initial temperature overshoots against the target values. It also reduced the operatingtime of the hot water circulation pump. Such positive results were possible due to our unique strategy that exploits heating efficiency information collected from the past run of the very same system. Since the strategy was implemented with embedded software, it makes the BoilerMan flexible, too.
        4,000원
        6.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We have performed the flat-fielding correction for the Hα full-disk monitoring system of KASI (Korea Astronomy and Space Science Institute), which is installed in the Solar Flare Telescope (SOFT) at the top of Bohyun Mountain. For this, we used a new method developed by Chae (2004), to determine the flat pattern from a set of relatively shifted images. Using this method, we successfully obtained the flat pattern for Hα full-disk observations and compared our result with the image observed in Catania Astrophysical Observatory. The method that we used in this study seems to be quite powerful to obtain the flat image for solar observations. In near future, we will apply this method for the flat-fielding correction of all solar imaging instruments in KASI.
        4,000원
        7.
        2002.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        방수시스템의 거동은 재료 인자들의 복잡한 상호작용, 설계 상세, 그리고 시공의 질에 따라 결정되고, 방수성은 교면과의 접착성과 방수재의 손상정도에 의해 결정되는 것으로 알려져 있다. 따라서 본 연구는 현재 국내에 유통되고 있는 교면방수재의 종류별로 방수시스템의 성능을 현재 각 시공현장에서 하자의 원인으로 가장 빈번하게 발생되는 요인들을 중심으로 인장접착 특성을 비교하였다. 방수시스템에 대한 인장접착강도 시험 결과, 함수비 10% 이상에서는 무기질탄성계 도막방수재를 제외하고는 접착력이 감소하였으며, 바닥판 콘크리트 강도가 증가할수록 일반적으로 인장접착강도는 증가하였다. 또한 바닥판 콘크리트의 양생방법에 따라 내부의 공극구조 및 평탄성의 차이로 인해 수중양생한 시편이 전반적으로 접착력이 더 큰 것으로 나타났다. 아스팔트 혼합물 포설전 보다 아스팔트 혼합물 포설후 인장접착강도가 증가하는 경향을 나타냈지만 도막식의 경우, 오히려 감소하는 결과가 나타났다. 그리고 방수재 시공시 대기온도가 상승함에 따라 접착력이 저하되어 방수 시스템의 성능에 악영향을 미치는 것으로 나타났다.
        4,000원
        8.
        2002.09 구독 인증기관 무료, 개인회원 유료
        방수시스템의 거동은 재료 인자들의 복잡한 상호작용, 설계 상세, 그리고 시공의 질에 따라 결정되고, 방수성은 교면과의 접착성과 방수재의 손상정도에 의해 결정되는 것으로 알려져 있다. 따라서 본 연구는 현재 국내에 유통되고 있는 교면방수재의 종류별로 방수시스템의 성능을 현재 각 시공현장에서 하자의 원인으로 가장 빈번하게 발생되는 요인들을 중심으로 인장접착 특성을 비교하였다. 방수시스템에 대한 인장접착강도 시험 결과, 함수비 10% 이상에서는 무기질탄성계 도막방수재를 제외하고는 접착력이 감소하였으며, 바닥판 콘크리트 강도가 증가할수록 일반적으로 인장접착강도는 증가하였다. 또한 바닥판 콘크리트의 양생방법에 따라 내부의 공극구조 및 평탄성의 차이로 인해 수중양생한 시편이 전반적으로 접착력이 더 큰 것으로 나타났다. 아스팔트 혼합물 포설전 보다 아스팔트 혼합물 포설후 인장접착강도가 증가하는 경향을 나타냈지만 도막식의 경우, 오히려 감소하는 결과가 나타났다. 그리고 방수재 시공시 대기온도가 상승함에 따라 접착력이 저하되어 방수 시스템의 성능에 악영향을 미치는 것으로 나타났다.
        4,000원
        9.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        논문은 바닥 격막을 고려한 초고층 아웃리거 구조시스템의 수평거동을 파악하기 위하여 80층 규모의 초고층 아웃리거 건물을 대상으로 MIDAS-Gen을 이용하여 계획설계 수준의 구조설계를 진행하였다. 그리고 본 해석의 주요한 변수는 아웃리거의 평면상 위치, 슬래브의 강성, 아웃리거의 강성, 다이어프램의 종류이다. 또한 본 연구의 목적을 위하여 최상층에서 발생하는 수평변위, 층간변위, 슬래브에 발생한 응력을 분석하였다. 본 연구의 결과, 아웃리거의 평면상 위치, 슬래브의 강성, 아웃리거의 강성, 다이어프램의 종류는 초고층 아웃리거 구조시스템의 수평거동에 영향을 주는 것으로 나타났다. 그리고 본 연구의 결과는 초고층 아웃리거 구조시스템의 수평거동을 파악하는데 필요한 구조설계 기본자료를 얻는데 도움이 된다고 사료된다.
        10.
        2013.10 서비스 종료(열람 제한)
        In this study, 3-axes controllable base isolation system is developed in consideration of mechanical performance(hysteresis and damping characteristics), maintenance and control method for ordinary submicro vibration. Also, seismic performance is evaluated by shaking table test.
        11.
        2012.11 서비스 종료(열람 제한)
        The purpose of this study is to develop structral technologies on the lightweight composite slab systems with sound reduction layers in the modular house. In this study, two kinds of slabs with minimum thickness was suggested reducing the floor impact sound. In order to evaluate the structural performance, the flexural strenth tests were carried out on the one-way full scale specimens. From the results of test, we know that the proposed slabs had ductile behavior and would be safe sufficiently.
        12.
        2010.07 KCI 등재 서비스 종료(열람 제한)
        LNG 천연가스로서 저장과 운반이 용이한 액체로 변형이 가능하며, 청정연료로 각광받게 되어, 석유에너지의 의존도를 낮추고 에너지사용의 다변화를 위해 1986년 인도네시아로부터 처음 도입된 이래로 산업의 성장과 더불어 그 수요량이 지속적으로 증가하고 있다. LNG는 천연가스의 부피를 영하 약 -162℃(-260℉)까지 냉각시켜 1/600까지 줄일 수 있으므로, 저장 및 운반에 있어서 매우 효율적이다. 현대의 LNG 저장탱크는 철근 콘크리트 이중벽과 내부 니켈방호벽 및 벽사이의 효율이 높은 단열재로 구성된 완전 방호식이 적용되고 있다. 단열재는 극저온의 온도가 LNG 탱크 외벽으로 전달되는 것을 차단하며, 바닥슬래브, 외벽 및 상부에 설치된다. LNG 저장탱크의 단열재의 배치에 따라 콘크리트 외조에 작용하는 온도분포에 차이가 나므로, 본 연구에서는 기 건설된 완전 방호식 LNG 저장탱크 바닥판 단열재의 배치에 대해 검토하고, 이를 바탕으로 단열시스템 개선 방안을 제안하고자 한다.