검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        2.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, interest in the development of alternative water resources has been increasing rapidly due to environmental pollution and depletion of water resources. In particular, seawater desalination has been attracting the most attention as alternative water resources. As seawater desalination consumes a large amount of energy due to high operating pressure, many researches have been conducted to improve energy efficiency such as energy recovery device (ERD). Consequently, this study aims to compare the energy efficiency of RO process according to ERD of isobaric type which is applied in scientific control pilot plant process of each 100 m3/day scale based on actual RO product water. As a result, it was confirmed that efficiency, mixing rate, and permeate conductivity were different depending on the size of the apparatus even though the same principle of the ERD was applied. It is believed that this is caused by the difference in cross-sectional area of the contacted portion for pressure transfer inside the ERD. Therefore, further study is needed to confirm the optimum conditions what is applicable to the actual process considering the correlation with other factors as well as the factors obtained from the previous experiments.
        4,000원
        3.
        2016.05 구독 인증기관·개인회원 무료
        재래식 해수담수화 수평적 압력용기 설계는 후단에 있는 역삼투막에는 농축수에 의해 수질악화 및 생산수저감 등이 동반된다. 이를 해결하기 위해 본 연구에서는 개념적인 중앙 주입식 압력용기가 생산수 단가에 미치는 영향과 역삼투 공정 설계 시 주요 인자들이 성능에 미치는 영향을 조사를 위해 상업화된 역삼 투 프로그램인 ROSA를 이용하여 분석하였다. 그 결과 중앙 주입식 압력용기를 이용할 경우 총괄적인 회수율과 SEC 측면에서 성능이 저하하지만, 막 모듈 당 생산되는 생산수량이 증가하는 것으로 나타났다. 또한 생산수의 수질개선은 2단 설계의 용량 감소로 인하여 건설비 저감으로 연계되는 것으로 조사되었다. 본 연구는 국토교통부 플랜트연구사업의 연구비지원(과제번호 16IFIP-B089908-03)에 의해 수행되었습니다.
        4.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 국내 최초로 도입된 Y 정수장의 세라믹막 고도정수처리를 위한 최적 운영 인자를 도출하기 위하여 수행되었다. 경제성과 수질조건을 만족하면서도 세라믹막 여과성능을 지속⋅유지할 수 있는 최적 운영조건을 도출한 결과, Y 정수장의 평상시 수질 조건에서 막역세척으로 인한 배출수 발생량을 최소화시키면서도 막여과성능을 유지할 수 있는 최적 여과지속시간(역세척 주기)은 시설용량(16,000 m3/일) 기준 시 4.0시간으로 조사되었다. 또한 화학세척(CIP)에 따른 막차압 회복력을 조사한 결과, 구연산을 이용한 산세정을 통하여 철, 망간, 알루미늄 등의 막 파울링을 일으키는 무기오염물질은 제거되지만 막 회복률은 낮았다. 반면 차아염소산나트륨을 사용한 알칼리 세정을 통해서는 막 운영 초기 막차압으로 회복되는 것으로 나타났다. 막차압을 발생시키는 파울링 주요 원인물질은 친수성 고분자 유기오염물인 polysaccharides로 조사되었으며, 화학세척(CIP)시 막성능 회복률은 세척약품 온도에 의한 영향이 매우 크며, 온도가 높은수록 막성능 회복률이 향상되는 것으로 조사되었다.
        4,300원
        5.
        2009.11 구독 인증기관 무료, 개인회원 유료
        Semiconductor industry is based on equipment industry and timing industry. In particular, semiconductor process is very complex and as semiconductor-chip width tails and is becoming equipment gradually more as a high technology. Equipment operation is primarily engaged in semiconductor manufacturing (engineers and operator) of being conducted by, equipment errors have also been raised. Equipment operational data related to the error of korea occupational safety and health agency were based on data and production engineers involved in the operator's questionnaire was drawn through the error factor. Equipment operating in the error factor of 9 big item and 36 detail item detailed argument based on the errors down, and 9 big item the equipment during operation of the correlation error factor was conducted. Each of the significance level was correlated with the tabulation and analysis. Using the maximum correlation coefficient, the correlation between the error factors to derive the relationship between factors were analyzed. Facility operating with the analysis of error factors (big and detail item) derive a relationship between the model saw. The end of the operation of the facility in operation on the part of the two factors appeared as prevention. Safety aspects and ergonomics aspects of the approach should be guided to the conclusion.
        4,800원
        7.
        2011.04 KCI 등재 서비스 종료(열람 제한)
        Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm × height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).