As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.
(주)에코니티에서 개발한 자유말단형 분리막모듈(End-Free type)은 기존 분리 막 모듈과는 달리 고농도의 MLSS(Mixed Liquor Suspended Solids) 에서도 지속적인 운전이 가능하며, 그 외 다양한 현장 문제 발생 시에서도 쉽게 대응이 가능하여 안정적으로 운영이 가능한 특징을 가지고 있다. 본 연구에서는 (주)에코니티 자유말단형 분리막의 MBR(Membrane Bioreactor) 장기 운전 성능을 평가하였다. 운영을 하는 동안 발생하는 이벤트에 대한 해결 방안을 확인하면서 최적의 운전조건을 검토하였다. 또한 하수처리수가 재이용으로 적용되는 시스템에서 MBR 처리수가 역삼투 멤브레인의 원수로 공급되는 만큼 안정적이며 양호한 수질이 생성되는지 지속적으로 검토하였다.
일반적인 MBR공법의 경우 허용한계 이상의 고농도 MLSS에서 운영되면 막오염이 급격히 발생된다. 이는 슬러지 케익 축적이 원인이며 이로 인해 분리막 회복을 위한 빈번한 세정이 적용되어야 하고 그 결과 운영비 증가 및 분리막 수 명이 단축된다. 본 연구에서는 (주)에코니티의 자유말단형(End-Free) 분리막을 이용한 MBR 시스템 운전을 진행하였다. 분리막 모듈의 구조적인 특성으로 슬러지가 쉽게 탈리되어 케익의 축적이 발생하지 않아 고농도 MLSS에서도 적용가능함을 확인 하였다. 이에 따라 운전 플럭스를 상향시킬 수 있었고 장기 운전을 통하여 막여과 시스템의 안정운영을 평가하였다.