검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 10

        2.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The volume of fluid method is used to investigate the behavior of a liquid water slug in a PEMFC trapezoidal gas channel(GC) with a open angle of 60 degrees. To evaluate the effect of the contact angle of the top and side walls, the gas diffusion layer water coverage ratio(GWCR) and water volume fraction(WVF) in a inspection control volume are analyzed. As the contact angle increases, GWCR increases and WVF decreases. The cases with the GC contact angle of 60 and 80 degrees show the more favorable water removal characteristics compared to the other cases in a GC flooding condition.
        4,000원
        3.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The volume of fluid method is applied to study the effects of the gas channel wall contact angle on the removal characteristics of a water slug in a right angle PEMFC gas channel. While maintaining the same GDL surface contact angle, two different contact angle distributions on the control area in the corner region are compared via the water coverage ratio and water volume fraction. The water coverage ratios of the hydrophobic channel corner case mainly show smaller values than that of the hydrophilic case except around 27 ms. The water volume fraction of the hydrophobic corner case is supposed to drop down quickly around 27 ms due to the dynamic movement of the liquid water compared to the hydrophilic case. In overall, the hydrophobic corner case shows better water slug removal characteristics.
        4,000원
        4.
        2015.11 구독 인증기관 무료, 개인회원 유료
        To study the effects of the gas channel wall contact angle on the behavior of a liquid water slug, numerical simulations are performed with the volume of fluid (VOF) method. Two different contact angle combinations on the side and top channel walls are selected. In comparison to the reference case, the water slug is removed faster when the hydrophobic contact angle is applied selectively in the corner section.
        3,000원
        5.
        2014.11 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Hydrophilic SiO2 layers were obtained by the atmospheric-pressure plasma treatment. Superhydrophobic SiO2 layers were first deposited by the electrospray deposition method. The electrospunable solution that was prepared based on the solgel method was sprayed on Si (100) substrates. The surface of the electrosprayed SiO2 layers consisted of the agglomeration of nano-sized grains, which led to a very high roughness and revealed a very high contact angle to water droplets over 162˚. After having been exposed to the atmospheric Ar/O2 plasma, the observed superhydrophobicity of the SiO2 layers were greatly changed: a dramatic variation of the water contact angle from 162˚ to 3˚, namely realization of superhydrophillicity. Interestingly, the surface microstructure was almost preserved. According to the XPS analysis, it is more likely that thanks to the plasma exposure, the surface of SiO2 layers will be cleaned in terms of organic species that are hydrophobic-inducing, consequently leading to the hydrophilic nature observed for the plasma-exposed SiO2 layers.
        4,000원
        6.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Generally, in the previous researches, it is found that a water droplet is respectively in Wenzel and Cassie-Baxter states on hydrophilic/hydrophobic rough surfaces. And Wenzel and Cassie-Baxter equations are used to estimate the apparent contact angle on the surfaces. However, difference between measured apparent contact angle and estimated apparent contact angle with the equations is recently reported and new model to estimate apparent contact angle on rough surfaces is proposed. In this study, wetting state and apparent contact angle on the surfaces with micro-pillars should be investigated to find solution of this argument. Using the high resolution microscope, the wetting state of the D.I.water droplet on the surface with micro-pillars was visualized and apparent contact angle of the D.I.water droplet was measured. On the basis of experimental data, the equations to estimate apparent contact angle were verificated and the general wetting characteristics on the surfaces with micro-pillars are finally classified.
        4,000원
        7.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적: 단백질 침전물이 콘택트렌즈의 함수율, 산소투과성 및 접촉각에 미치는 영향을 조사하였다. 방 법: Polymacon과 etafilcon A 재질의 소프트콘택트렌즈를 착용기간에 따라 수집하여 단백질 침전물을 추출하고 fluorometer를 이용하여 단백질 침전물을 정량하였다. 사용하지 않은 polymacon과 etafilcon A 콘택트렌즈를 lysozyme과 albumin 단백질이 포함된 인공눈물에 넣어 일정하게 단백질을 부착시키고 부착된 단백질 침전물을 정량한후 중량측정법, 전기분해 자동분석법 및 sessile drop 방법을 사용하여 함수율, 산소투과성 및 접촉각을 측정하여 대조군과 비교하였다. 결 과: Polymacon 재질의 콘택트렌즈에 부착된 단백질 침전물 양은 착용기간에 따라 차이가 없었으나, etafilcon A 재질의 콘택트렌즈는 착용기간에 따라 빠르게 증가하였다. 일정하게 단백질을 부착시킨 소프트 렌즈의 경우 함수율은 polymacon 렌즈와 etafilcon A 렌즈에서 모두 감소하였고, 산소투과성도 polymacon 렌즈와 etafilcon A 렌즈에서 모두 감소하였으며 접촉각은 polymacon 렌즈와 etafilcon A 렌즈에서 모두 증가하였다. 결 론: 소프트콘택트렌즈에 부착된 단백질 침전물은 렌즈의 함수율과 산소투과성을 저하시키고 접촉각을 증가시켜 콘택트렌즈 착용 시 불편감을 유발하는 원인이 될 수 있으며 특히 고함수 이온성 재질인 etafilcon A의 경우 더욱 문제가 될 것으로 사료된다.
        4,300원
        9.
        2009.12 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 극성 액체인 물, 에탄올 및 비극성 액체인 사염화탄소를 극성 표면인 유리와 비극성고체인 PVC와 테플론판 위에 떨어뜨린 후 접촉각을 측정하고, 액체-증기, 고체-증기, 및 고체-액체의 경계간의 자유에너지와 표면장력을 계산하였다. 접촉각의 크기는 액체의 종류 또는 표면장력 뿐 아니라, 고체 판의 특성에 따라서도 달라진다는 것을 확인하였다. 또한, 접촉각의 크기는 액체의 표면 장력의 크기와 반드시 일치하지는 않았다. 7차 교육과정의 ‘화학Ⅰ’ 교과서 8종과 여러 평가 문항들을 분석한 결과, 접촉각과 표면 장력의 크기를 단순히 분자 간 인력에 따라 비례하는 것으로 표현하는 경우가 있었고, 교육과정에서 요구하는 수준을 넘거나 현실적으로 관찰되지 않는 상황을 제시하는 경우도 있었다. 고등학교 학생들은 접촉각, 표면장력 그리고 분자간 인력에 관련된 이해가 부족한 것으로 나타났다.