A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.
완공된 건물과 달리 시공 중인 건물은 설계단계와 다른 하중 작용 및 콘크리트 강도 미발현 등 다양한 요인에 의해 설계단계에서 검 토한 하중을 초과하는 하중이 작용하여 건물의 안전성에 문제가 생길 위험이 있다. 또한 시공 중인 건물에 지진이 발생할 경우 더 큰 피해가 발생할 가능성이 있다. 따라서 이 연구는 전형적인 다양한 규모의 5층, 15층, 25층, 60층 예제모델을 작성하고 골조완성도에 따 른 시공단계 모델을 통해 시공 중인 건물의 지진하중의 영향을 분석하였다. 시공 중인 건물의 시공기간은 완공단계 이후의 사용기간 에 비해 매우 짧으므로 설계단계와 동등한 수준의 지진을 적용하는 것은 과도한 하중이 적용될 수 있으므로 시공단계 모델에 재현주 기 50~2,400년의 지진을 적용하여 지진하중을 검토하고 부재단면성능을 분석하였다. 그 결과 설계단계를 초과하는 하중의 여부 및 구조적 안전성 확보가 가능한 수준의 지진재현주기를 검토할 수 있었다. 또한 각 예제모델의 시공기간을 가정하여 시공기간에 따른 지진재현주기를 선정하고 선정한 재현주기의 설계 적절성을 확인하였다.
시공 중인 건물은 시공이 완료된 건물과는 다르게 콘크리트의 강도발현이 충분히 이루어지지 않았기 때문에 지진과 같은 자연재해 에 더 취약한 모습을 가질 수 있다. 현재 국내 기준은 건축물의 내진등급별 최소성능 목표를 제시하고 있지만, 설계를 위한 지진하중은 재현주기 2,400년의 지진위험도를 기반으로 한다. 하지만 건물의 시공기간은 건물의 사용기간보다 훨씬 짧기 때문에 재현주기 2,400 년의 지진을 시공 중인 건물에 적용하는 것은 과도하다. 따라서 이 연구는 주거용으로 사용되는 철근콘크리트 건물의 시공 중 지진하 중을 분석하기 위해 5층, 15층, 25층, 60층 건물의 시공단계모델을 작성하고 재현주기에 따라 저감한 지진하중을 적용하여 구조적 안 정성을 확인하였다. 그 결과, 시공기간에 따라 선정한 재현주기의 지진을 적용할 때 구조적 안정성을 확인하였으며, 건물의 규모의 따 라 구조적 안전성을 확보할 수 있는 지진재현주기를 확인하였다.
본 연구의 목적은 방진층을 가진 바닥판을 포함한 건축물의 동적해석을 위하여 효율적인 모형화 방법과 이에 대한 해석법을 제안하는 것이다. 이를 위하여 방진층을 포함한 바닥판의 모형화를 위하여 바닥슬래브와 상부 마감층을 각각 독립적으로 모형화하고 이들 사이에 방진층을 의미하는 스프링 요소를 사용하였으며 방진층의 감쇠에 의한 비비례 문제를 해결하기 위하여 Newmark-{\beta}법을 적용하여 동적해석을 수행하였다. 상하부를 각각 모형화함으로서 방진층 상하부의 재료적 차이에 의한 감쇠거동을 정확하게 모형화할 수 있었다.
Through The Japanese case that they prevent earthquake damage by using seismic design, we design a building that before reform seismic design and conduct a seismic design evaluation.
For detail evaluation, we use Nonlinear Static Analysis and find performance point that using by Capacity Spectrum Method of procedure B and Displacement Coefficient Method.
We compared performance point of Capacity Spectrum Method of procedure B and target displacement of using Displacement Coefficient Method. Consequently we obtain a result that those are similar.
Result of understanding each element performance level that base on performance point, some elements are unsatisfactory. Thus, We have come to conclusion that re-evaluate after reinforce structure.
This is preliminary study for development of specialized seismic performance evaluation and reinforce guidelines for piloti-type buildings. A residential Building with Pilotis was selected and the seismic performance evaluation was performed. The vulnerable parts of the piloti-type building for earthquake and the risks are verified. Finally, the necessity of evaluation and reinforce guidelines for the building with pilotis is presented.
본 연구에서는 주거용 무량판구조의 내진성능을 개선하기 위한 면진적용 가능성을 평가하였으며, 시간이력 해석을 위한 지진기록 사용에 대한 문제점을 제시하였다. 면진층 강성 및 주기 평가 및 포락해석법을 적용하여 면진전 비틀림 모드가 강한 구조물을 면진시스템 적용으로 내진성능을 개선하였다. 지진기록 사용 및 크기 조절효과의 적정성을 평가하기 위하여 DBE, MCE, ASCE 7-05의 1.4DBE 의해 크기를 조정한 시간이력 해석결과를 비교한 결과, 구조물의 지반조건과 유사한 조건에서 관측된 지진기록 및 지진기록의 응답이 설계규준 응답스펙트럼의 평균±표준편차 범위 안에 있는 기록을 사용하는 것이 적절한 것으로 판단된다.