PURPOSES : This study prioritizes the potential technology for establishing an efficient traffic control in the ramp junction of urban deep underground tunnels in the future. We considered most of the applicable technologies that ensure traffic safety at the on-off ramp junction.
METHODS : This study proposes a methodology to prioritize the applicable technology for establishing efficient traffic control in the ramp junction of an urban deep underground tunnel using an analytical hierarchy process (AHP). First, an AHP structure was developed. Second, an individual survey was conducted to collect the opinions of road and transportation experts. Based on the survey results, weights were estimated depending on the relevant criteria of the developed structure. The estimated weights were verified using the consistency index (CI) and consistency ratio (CR). In addition, a sensitivity analysis was performed to confirm the reliability of the estimated weights. Finally, the potential technology for an efficient traffic control in the ramp junction of an urban deep underground tunnel was prioritized.
RESULTS : In the first level of hierarchy, traffic demand control had the highest priority, and ramp metering, section speed control, and shoulder lane control were selected in the second level of hierarchy.
CONCLUSIONS : These results implied that prioritizing would be useful in establishing traffic operation strategies for traffic safety when constructing and opening deep underground tunnels in urban areas in the future.
본 연구는 백화산 지역의 고도별 식물 종풍부도 패턴 및 서식지 인자인 면적, 경사도와 기후 인자인 연평균 기온 및 강수량이 고도별 식물 종풍부도 패턴에 미치는 효과를 구명하기 위해 수행되었다. 식생 조사 결과, 목본 식물 66종, 초본 식물 88종, 총 154종의 식물종이 관찰되었다. 고도에 따라 전체 식물 종 및 목본 식물종의 풍부도는 감소하는 패턴을 나타낸 반면, 초본 식물종의 풍부도는 특정 패턴을 나 타내지 않았다. 또한, 이러한 분포 패턴을 제어하는 인자로서 단순회귀 분석 및 편회귀 분석을 통한 변 이분할 결과, 서식지 인자인 면적과 기후 인자인 연평균 기온 및 강수량이 목본 식물 종풍부도를 예측 하는 가장 중요한 인자로 나타났으며, 서식지 인자인 경사도가 초본 식물 종풍부도를 제어하는 중요한 인자로 나타났다. 또한, 전체 식물종의 풍부도를 예측하는데 있어서 서식지 인자인 면적과 경사도가 중 요한 인자로 나타났다. 본 연구는 소규모 개별 산림에 자생하는 식물이라고 하는 동일한 분류군 내에서 도 식물 그룹에 따라 고도별 분포 패턴 및 제어인자가 상이하다는 것을 제시하며, 백화산 지역의 식물 다양성을 제어하는 인자가 단순히 하나가 아닌 몇 가지 인자에 의한 복합작용에 의해 나타나는 현상임 을 의미한다.
In this study, the actual energy consumption of the secondary side of district heating system(DHS) with different hot water supply temperature control methods are compared. Two methods are outdoor temperature reset control and outdoor temperature predictive Control. While outdoor temperature reset control has been widely used for energy savings of the secondary side of the system, the results show that outdoor temperature predictive control method saves more energy. In general, outdoor temperature predictive control method is lowering the supply temperature of hot water, and it reduces standby losses and increases overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, outdoor temperature predictive control method saves about 19.1% when it compared to outdoor temperature reset control method. Also, it is found that when partial load condition, such as daytime, the fluctuation of hot water supply temperature with outdoor temperature reset control is more severe than outdoor temperature prediction control. So, it proves that outdoor temperature prediction control is more stable even at partial load conditions.
In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.
본 연구에서는 특수재난 현장에 대응하기 위한 정찰 및 원격제어시스템을 연구하였다. 특수재난현장은 정의는 다양할 수 있으나 본 연구에서는 대형 재난현장 즉, 원자력사고 또는 화생방 테러, 이상기후로 인한 홍수해로인한 도심침수현장, 대형실내화재현장과 같은 소방대원의 투입이 어려운 현장을 대상으로 정의하였다. 이러한 특수재난 현장은 재난 현장 상황을 파악하기 힘들고 소방관이나 구급대원 투입시 2차적인 사고로 이어질 수 있다. 이러한 재난 현장 상황에 따라 유선 및 무선조작을 통하여 출입문 개방 및 위험지역 내부 상황모니터링이 가능한 특수재난지역 투입용 최첨단 소방정찰로봇 및 이를 운반 또는 소방관 탑승 및 원격조작이 가능한 특수재난지역 최첨단 소방대응시스템을 연구하였다. 시스템은 4개 부분으로 구분된다. 크기에 따라 소형, 중형, 대형 플랫폼으로 구분하고 이를 이송할 수 있는 전용 이송차량으로 구성된다. 소형 플랫폼은 홍수 및 침수지역에서 정찰하기 위한 것으로 수심 10m 에서도 정찰이 가능하도록 하였고 중형 플랫폼은 재난 지역의 통로를 개척하기 위하여 출입문을 파쇄하고 진입하기 위한 기능을 가진다. 대형 플랫폼은 소방관이 탑승하기 위한 구조로 연구되고 있다. 원격조정도 가능고 상황이 따라 소방관이 직접 운전하면서 화재 현장의 화점을 조준하여 소화할 수 있는 구조이다. 3개의 플랫폼마다 저마다의 특성과 기능을 가지고 있으며 재난형장 출동시 세 개의 플랫폼을 동시에 이송시킬 수 있는 특수 이송차량을 개발하고 있다.
Adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated in this study. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses.