검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 15

        1.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The annual total phosphorus load caused by public wastewater, nightsoil and livestock manure treatment facilities in Korea has been examined macroscopically. Annual domestic average phosphorus (P) inflows through the income of phosphate rock for the last five years (2012 - 2016) were analyzed as 76,598 tons/year. As of the year 2015, the total loadings of phosphorus attributed to public wastewater treatment facilities, nightsoil treatment facilities and livestock wastewater were estimated as 30,269 tons/year, 1,909 tons/year and 18,138 tons/year, respectively. Considering the amount of phosphorus imports, the annual phosphorus load from wastewater, livestock wastewater and excretions is equivalent to 39.5%, 23.7%, 2.5% and totally 65.7%(39.5% + 23.7% + 2.5%). Therefore, the introduction of phosphorus recovery and recycling processes for the public wastewater and livestock manure treatment facilities has been found to be effective because it could reduce the import amount of phosphate rock by up to 60% or more.
        4,300원
        2.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 시설하우스에서 비점오염원으로 인해 배출되는 오염된 농업배수를 인공습지에서 효과적으로 처리하기 위한 기초자료를 확보하기 위해 인공습지에서 여재종류, 조합방법 및 부하량에 따른 오염물질 정화효율을 평가하였다. 인공습지의 조합방법은 수직-수평흐름조, 수평-수직흐름조, 수평-수직-수평흐름조 및 수직-수평-수평흐름조로 구분하여 설계 및 시공하였으며, 여재는 왕사, 쇄석, 방해석 및 혼합여재로 구분하여 각 조에 충진하였다. 또한 농업배수 부하량을 150, 300, 600 L m-2 day-1으로 달리하여 오염물질의 처리효율을 조사하였다. 조합방법별 수처리효율은 HF-VF-HF 조합방법이 다른 조합방법에 비해 높은 처리효율을 보였으며, 최적여재는 COD 처리효율은 왕사가 가장 높았고, T-N은 쇄석, T-P는 방해석이 가장 높았다. 하지만 모든 처리효율과 경제성 부분을 고려하였을 때 최적여재는 혼합여재가 가장 효과적일 것으로 판단된다. 농업배수의 부하량에 따른 처리효율 결과 COD는 농업배수 부하량 600 L m-2 day-1까지 안정적인 처리효율을 보였으나, T-N 및 T-P는 150 L m-2 day-1≒300 L m-2 day-1¤600 L m-2 day-1의 순으로 농업배수의 부하량이 증가함에 따라 약간 감소하는 경향이었다. 따라서 시설하우스 농업배수 처리를 위한 인공습지 농업배수처리장의 최적조건은 HF-VH-HF 조합형 인공습지에 왕사, 쇄석 및 방해석이 혼합된 혼합여재로 충진하고 부하량 300 L m-2 day-1 이하의 농업배수를 주입하는 것이 최적일 것으로 판단된다.
        4,200원
        3.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 하수처리장 방류수가 하천 유기물 오염에 미치는 영향을 파악하기 위하여 구미시 관내에 위치한 구미 4단지, 구미, 구미 원평하수처리장 방류수와 처리장 상∙하류 하천을 조사하였다. TOC 중 DOC가 70% 이상 으로 대부분 용존성으로 존재하였고, TOC에 대한 BOD, CODMn의 산화율은 각각 13~43%, 37~73%로 나타났다. 하지만 현재 사용되고 있는 BOD, CODMn이 총 유기탄소 에서 차지하는 비율이 약 50% 이하로 나타나, 유기물을 대표하는 데 어려움이 있을 것으로 보이며, 향후 TOC로 지표를 전환하는 방향도 모색해 보아야 할 것으로 판단 된다. DOC 분해실험 결과 DOC 중 R-DOC가 70% 이상 으로 난분해성 유기물이 대부분을 차지하는 것으로 나타 났다. 하수처리장 방류수의 유기물이 하천에 미치는 영향 을 보면, 낙동강 하류에서 구미 4단지, 구미, 구미 원평하 수처리장 방류수의 총 TOC 부하량이 차지하는 비율은 15%로 나타났다. 총 비율은 15%로 비교적 많은 부분을 차지하지는 않았지만 이 중 생분해성 유기물보다 난분해 성 유기물이 더 많은 부분을 차지하는 것으로 나타나, 상 수 처리 시 소독부산물의 전구물질이 증가하는 원인으로 작용할 수 있을 것으로 판단된다.
        4,000원
        4.
        2007.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        다분야통합해석에 기반한 설계문제는 일반적으로 전체 설계과정에서 매우 큰 계산시간을 요구하며, 이러한 계산시간을 단축하기 위해 병렬처리시스템을 도입하는 것이 필수적이다. 그러나 다분야통합해석에 기존의 병렬처리기법을 적용하기 위해서는 해석에 필요한 모든 CAE 소프트웨어들이 병렬처리시스템의 모든 서버에 설치되어 있어야 하며, 이는 매우 큰 CAE 소프트웨어의 비용을 필요로 한다. 본 논문에서는 이러한 문제점을 해결하기 위해 가중치 기반 멀티큐 부하분산 알고리즘을 제안하였다. 제안된 알고리즘은 서버들의 성능과 설치된 CAE 소프트웨어들의 종류가 각기 다른 이종 병렬처리시스템을 고려하였으며 성능검증을 위해 선입선출(First Come First Servre) 알고리즘을 적용한 경우와 비교한 전산실험을 수행하였다.
        4,000원
        5.
        2002.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to study the change of pollution loads flowing into Mokpo harbour after the operation of Mokpo Municipal Sewage Treatment Plant (MMSTP) and to evaluate the contribution of MMSTP operation to the improvement of marine water quality of Mokpo harbour, the pollution loads flowing into Mokpo harbour from land in dry weather were surveyed and estimated on the bases of the seasonal flow rates and the seasonal water qualities of streams and effluents located around Mokpo harbour from summer, 1997 to spring, 1998 before the operation of MMSTP, and the pollution loads of the inflow and the effluent of MMSTP were also surveyed and estimated from winter, 1998 to spring, 1999 after the operation of MMSTP. The treatment rates of MMSTP were shown to be about 49% in COD, 76% in TSS, 79% in VSS, 3% in T-N, 7% in DIP, 29% in T-P and -32% in DIN. The change rates of pollution loads flowing into the inner harbour of Mokpo due to the operation of MMSTP were shown to be about 56% In COD, 78% in TSS, 84% in VSS, 45% in DIN, 22% in T-N, 34% in T-P and -14% in DIP. The contribution rates of MMSTP operation to the reduction of total pollution loads flowing into the entire Mokpo harbour were found to be about 3% in COD, 3% in 755,5% in VSS,1% in DIP, 3% in T-P and -1% in DIN.
        4,000원
        6.
        1994.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the unit processes in the typical water treatment plant, which need to be expanded because the water demand is over the existing water treatment capacity in the near future, were carefully examined to upgrade the water treatment plant. The models were installed in the fields as a distorted model based upon the hydraulic similitudes. The models having the constant discharge ratio in the unit processes between the model and the prototype were installed as two units to compare the treatment efficiencies. The capacity of the individual unit, which is a model of the prototype of $250,000m^3/day$ capacity, was $24m^3/day$. In the mixing and flocculation experiments, the mixing intensity of flocculators G was selected as the main experimental item. The optimal mixing intensities G, which are 65/sec for experimental discharge of $1m^3/hr$ and 85/sec for experimental discharge of $1.3m^3/hr$, are identified based upon the comparison the relative turbidity removal efficiencies. Also, the outlet weir loading was selected as the main experimental item in the sedimentation process. Through the continuous experiments with the main experimental items of the mixing intensity of flocculators G and the outlet loading of the weir in the sedimentation basin, about 20% upgrading compared to the existing water treatment capacity was obtained.
        4,000원
        7.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        지속적인 개발과 도시화로 인하여 하천으로 유입되는 비점오염원의 비율 역시 점차 증가하는 추세이며 비점오염원이 수질악화에 미치는 영향은 점점 더 커지고 있다. 하천의 수질오염을 발생시키는 비점오염원 해결방안을 모색하고 있지만 도시화에 따른 수문현상변동 및 자연현상과 관련된 문제라 연구에 어려움이 많다. 본 연구에서는 기존의 총량원단위법과 달리 유역의 강우 및 도시화 특성과 처리장 운영자료를 활용하여 차별화된 비점오염원 산정 방법을 제시하였다. 하수처리장의 배수구역 내 관거시스템을 합류식으로 가정하여 강우 시 하수처리장의 배수구역별 비점 발생형태는 하수처리장 강우유입량, 하수처리장 우회유량(bypass) 및 하천 토구의 CSO의 3가지로 크게 구분하여 적용함으로써 오염부하량을 산정함으로써 오염총량 단위유역 및 하수처리구역의 관리를 위한 비교자료로 활용 가능할 것으로 판단된다.
        8.
        2013.12 KCI 등재 서비스 종료(열람 제한)
        This study investigated water quality of effluents and stream from the sewage treatment plants located at Gumi Complex 4, Gumi, and Wonpyeong in Gumi. Downstream region was found to increase the concentration of nutrients for sewage treatment plant effluent. Both phosphorus and nitrogen were accounted most as soluble form. In particular, the high ratio of dissolved effluent of sewage treatment plants were investigated. In the streams, Phosphorus concentration was high during rainy season and nitrogen concentration was high in the dry season. Sewage treatment plant effluent was relatively less microbial activity and nutrient concentrations were higher in the winter. TN/TP ratio was the highest in the upstream region and the lowest in the sewage treatment plant effluent. The effect of the nutrient matter from a discharge of a sewage treatment plant on rivers varied depending on the size of the river and the treatment plant. However, the influence of the concentration was greater than that of flowrate. Sewage treatment plant effluent loads phosphorus, nitrogen accounted for 8% and 6% respectively at the point N3 of the Nakdong river.
        11.
        2005.08 KCI 등재 서비스 종료(열람 제한)
        The purpose of this research was to investigate applicative possibility of field. Pilot-scale experiments were conducted, at outdoor temperature, HRT 10hour, IR(Internal Recycle) 150% and used 2.8㎥ Reactor. External carbon source was varied 80 to 120 mg/L. When External carbon source and Alkalinity were injected to the B3 pilot plant, the removal efficiencies of COD and BOD were not decreased. Nitrification rate were 5.95, 5.40, 4.08 mgNH4+-N/gSS/d during operation periods and denitrification rate was 3.12mgNO3--N/gSS/d. When we surveyed the relationship between loading rate of nitrogen and nitrogen removal quantity, this data was 0.949, B3 process will be possible application process of field.
        15.
        1993.12 KCI 등재 서비스 종료(열람 제한)
        A number of experiments were conducted in order to investigate the organic removal efficiency and biomass characteristics according to the organic shock loading rate in a fluidized bed biofilm reactor. At the operation conditions of HRT, 8.44 hour, superficial upflow velocity, 0.9 ㎝/sec and temperature, 22±1 ℃, the removal efficiency of SCOD was founded to be 96.5, 92 and 90 % with the organic shock loading rate of 3.5, 10.8 and 33 kgCOD/㎥·day, respectively. Within the F/M ratio ranged 0.4 to 2.0 ㎏COD/㎏VSS·day, the SCOD removal efficiency was shown as 90% at F/M ratio of 2.0 ㎏COD/㎏VSS·day, but the TCOD removal efficiency was 72 % at F/M ratio of 1.8 kgCOD/kgVSS·day. The average biomass concentrations were 7800, 14950 and 27532 ㎎/l on the organic shock loading rate of 3.5, 10.8 and 33 ㎏COD/㎥·day, respectively. This result was agreed with the fact that more biomass could be produced at high concentration of substrate, but some biomass was detached at the onset of shock and easily acclimated at the shock condition.