검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2000.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to investigate the application of ATP bioluminescence to measure the degree of microbial contamination from raw meat, meat processing and milk processing lines. Samples collected from slaughter house, meat and milk processing plants were tested for estimation of bacterial number by using ATP bioluminescence and conventional method. The former result was transffered to R-mATP value(log RLU/㎖), and the latter transffered to CFU(log/㎖). Correlation coefficient(r) between aerobic counts(CFU, log/㎖) and R-mATP(log RLU/㎖) value was 0.93(n=408). R-mATP of aerobic counts from beef, pork, chicken was 0.93(n=220), and that was 0.93(n=187) between meat processing and dairy processing plants. In addition, Correlation coefficient(r) between aerobic counts and R-mATP was 0.87(n=252) under 1 × 10^5/㎖ of bacterial count and 0.74(n=152) over l0^5 respectively.
        3,000원
        2.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 대전, 충청지역 초음파실 종사자를 대상으로 병원감염관리에 관한 설문 조사를 실시하여 분석 하였고, ATP를 이용하여 임상에서 사용되는 초음파 Probe의 오염도를 측정하였으며, 70% 알코올 이용하여 소독한 후 결과를 확인하였다. 기본적인 조사 대상자의 일반적인 특성 및 직종 별 대상자의 특성으로 나누어 학력, 직종, 초음파 전문자격증 보유 유무, 기관 내 감염 담당 부서 및 감염 교육의 여부를 분석하였다. 검사 후 젤 제거 여부 및 방법, Probe의 소독여부 및 변수 별 상관분석을 수행하여 초음파 Probe의 세균감염에 관한 인식 및 세척 및 소독에 대한 수행 정도를 분석하였다. 검사 후 Probe 세척에 관하여 수건을 가장 많이 사용하였으며, Gel 용기는 3개월 이상 교환하지 않는 것으로 나타났다. 70% 알코올 소독 후 ATP 오염도는 1055.4±944.2에서 133.5±93.2으로 감소하였고 통계적으로 유의한 것으로 분석되었다.(ρ<0.01) 병원 균종은 CNS, Gram positive bacillus, Micrococcus species 검출되었다. 이를 해결하기 위해 시중에서 손쉽게 구할 수 있는 70% 알코올을 이용하여 소독을 실시하였으며 소독 후 병원균종은 검출되지 않았다. 연구 결과 초음파실을 관리하는 의료인 또는 의료기사 등은 감염관리에 대한 주기적인 교육과 감염예방에 대한 노력이 필요하다고 볼 수 있으며, 70% 알코올은 병원균 사멸에 효과적인 것으로 나타났다. 따라서 의료기관은 적극적인 병원감염관리 교육을 실시하여 종사자들의 병원감염에 관한 인식을 개선하고, 환자 감염 예방에 기여해야 할 것이다. 또한 본 연구 결과를 적절히 활용한다면 초음파 Probe를 매개로 한 감염 예방에 도움이 될 것으로 사료된다.
        3.
        2012.02 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        With the rapid growth of fresh-cut produce market, the South Korean fresh-cut industry is facing the challenge of ensuring food safety. As the estimation of the microbial numbers in fresh-cut produce processing lines (tools, and equipment) using the conventional microbiological techniques takes days, so there is a need for faster and easier monitoring methods. This study was conducted to investigate the use of ATP bioluminescence assay to measure the degree of microbial contamination from three actual fresh-cut processing lines. The samples collected from frech-cut vegetables, and fresh-cut fruits processing plants were tested for the estimation of the bacterial number, using the ATP bioluminescence and microbiological methods. The result of former was transferred to log RLU/100 cm2, and that of the latter was transferred to log CFU/100 cm2. A positive linear correlation between the ATP bioluminescence assay value and aerobic-plate count was found for fresh-cut processing lines, with a correlation coefficient of 0.8772 (n=50). The results of this study indicate that ATP bioluminescence assay can be used to monitor microbial contamination in fresh-cut produce processing plants, and can help improve the hygiene therein.