검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Kinesio taping (KT) is an intervention method used to improve early function after surgery; however, the effect of KT varies depending on the intervention method. Objectives: To investigated systematically review and quantitatively analyze the effect of KT randomized controlled trials (RCTs) applied to Total knee arthroplasty (TKA) to determine the value of the treatment method for TKA patients. Design: A systemic review and meta-analysis. Methods: Studies were identified by searching multiple electronic databases from January 2023 to February 2023. We selected RCTs comparing KT or no treatment, standard physical therapy, multimodal therapeutic approaches. When possible, we pooled data using random-effects meta-analysis. The Cochrane Bias Method Group's seven-item risk of bias (RoB) assessment tool was used for RCTs. The main outcomes were pain, swelling, and ROM. Results: Three trials (290 patients) provided sufficient data and were similar enough to be pooled for meta-analysis. The standardized mean difference for a reduction of pain was SMD = -1.02, 95 % CI -1.93 to -0.12; p= 0.03; I2= 92 %. The standardized mean difference for a reduction of swelling was SMD= - 0.23, 95 % CI -0.50 to -0.05; p= 0.10; I2= 58 %. The standardized mean difference for ROM was SMD= 1.06, 95 % CI -0.08 to 2.20; p= 0.07; I2= 95 %. Conclusion: KT has a large effect on pain reduction in TKA patients and could be used as an additional treatment option, but a small effect was observed in swelling and ROM.
        4,000원
        2.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Total knee arthroplasty (TKA) recovers the alignment of the knee joint, but fails to automatically restore the alignment and function of the hip and ankle joints. It may affect the alignment and stability of the knee joint, therefore therapeutic intervention in hip and ankle joint is necessary for the rehabilitation process after TKA. Objects: The aim of this study was to comparison of the effects of the two exercise methods on the coronal plane alignment after TKA. This study conducted an experiment by dividing subjects into a lower extremity isometric co-contraction group (LEIC) and a quadriceps isolated isometric contraction (QIIC) group. Methods: A total of 37 subjects were randomly assigned to the LEIC (n1=19) or the QIIC (n2=18). Exercise was applied to five times per week for three weeks, starting on the eighth day after surgery. Range of motion exercises were performed as a common intervention and then each group performed quadriceps isometric contraction exercises with 10 sets of 5 repetitions. Radiological imaging was performed prior to surgery, one month and six months after surgery. In addition, the hip-knee-ankle angle (HKA) and tibiotalar angle (TTA) were measured. Results: The HKA was close to neutral in the LEIC rather than the QIIC (p<.05). The LEIC showed varus and the QIIC exhibited valgus TTA (p<.05). In a comparison of HKA and TTA over time, there was no significant change in either group (p>.05). According to the comparison of the TTA before surgery, the LEIC showed significant changes in the varus direction (p<.05), while there was no significant change in the QIIC (p>.05). Conclusion: The LEIC method triggered changes in the TTA and brought the HKA close to the neutral. Thus, LEIC is more effective than QIIC in creating stability in the coronal plane alignment of the knee and ankle joints after TKA.
        4,200원
        3.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In a total hip arthroplasty, the artificial hip joint is composed of an acetabular cup and a femoral head. To minimize the wear of the joint, the bearing surface should be precisely spherical. There were concerns that the press-fitting of the acetabular cup to the pelvis may cause the deformation of the cup and accelerate the wear of the joint, but its in-vivo measurement was challenging. In this paper, 3 dimensional finite element(FE) models of a pelvis and acetabular cups of Metasul 50mm and Pinnacle 50-60mm cups were used to simulate the deformation of the acetabular cups. For Metasul cups, the change of inner radius with respect to the location and the maximum shrinkage of the inner radius were found. For the Pinnacle cups, maximum change of the outer diameter were found and compared with the literature. FE model showed that the maximum shrinkage of the inner radius of the Metasul cup was 23μm (1.0mm press-fit, Bone stiffness 17GPa case). The shrinkage occurred mainly on the anterior and posterior side of rim of the cup, and the amount was proportional to the press-fit amount. The diametric change of the Pinnacle cup was 0.16mm on average, which was in same range of the clinically reported value. In conclusion, under the normal condition the reduction of the inner radius of the Metasul cup was too small to cause the jamming or the excessive wear.
        4,000원
        4.
        1997.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        임상 결과의 측정에서 새로운 관점을 갖는 것은 중요하다. 의료 재활은 심리적 측정의 질들(표준화, 신뢰도, 타당도)에서 충분한 노력에 수행되어지지 않아 왔기 때문에 환자와 프로그램 사이에 일반화된 기능적인 평가 범위가 부족하다. 장애의 적절한 측정을 위한 요구는 기능적인 상태에서 변화들을 알리고 치료의 필요성을 평가하고 치료를 계획하고 결과를 예측하고 보상 방법을 측정하기 위한 환자의 치료와 임상 연구에서 모두 나타난다. 세계적으로 사용되어지고 있는 기
        4,200원