        1.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 GFRP관을 상수도관으로 사용하기 위해 테스트베드를 설치하여 지중매설된 관의 구조적 거동에 미치는 영향을 조사하였다. 또한, GFRP관의 역학적 성질을 조사하고 관 강성을 추정하였다. KS규격에서 제시하고 있는 허용드로우와 고압력(사용압력의 1.5∼2.0배), 트럭하중을 적용시켜 관 내부와 외부의 복합하중이 작용할 경우 관 내압의 변화와 관의 거동을 확인하였다. 그 결과, 상수관으로 GFRP관을 장기 사용하여도 충분한 내압을 가지고 있음을 확인하였다.
        4,000원
        2.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipes are widely used in the water supply pipeline system. However, they have some disadvantages such as reduced durability due to material degradation, defects in connections, breakage of pipelines, and difficulties in continuous maintenance. To mitigate such problems, recently, research on durable and outstanding corrosion resistant glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, it should review the structural behavior and interaction between buried pipe and its surrounding soil because pipe will support the load with the surrounding soil together at the same time. To apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.
        4,000원
        3.
        2016.04 구독 인증기관·개인회원 무료
        In the water supply pipeline system polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipe are mostly used. However, they have some problems such as reduced durability due to material degradation, defects in connections, the pipelines breakage, and lack of continuous maintenance. Recently, research on durable and outstanding corrosion resistance glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, pipe will support the load with the surrounding soil. In this paper, to apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.
        4.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        GRP pipe (Glass-fiber Reinforced Plastic Pipe) lines making use of FRP (Fiber Reinforced Plastic) are generally thinner, lighter, and stronger than the existing concrete or steel pipe lines, and it is excellent in stiffness/strength per unit weight. In this study, we present the result of field test for buried GRP pipes with large diameter(2,400mm). The vertical and horizontal ring deflections are measured for 387 days. The short-term deflection measured by the field test is compared with the result predicted by the Iowa formula. In addition, the long-term ring deflection is predicted by using the procedure suggested in ASTM D 5365(ANNEX) in the range of 40 to 60 years of service life of the pipe based on the experimental results. From the study, it was found that the long-term vertical and horizontal ring deflection up to 60 years is less than the 5% ring deflection limitation.
        4,000원
        5.
        2020.02 KCI 등재 서비스 종료(열람 제한)
        우리나라의 연평균 지진발생 횟수는 꾸준히 증가하는 추세이다. 최근경주와 포항에서 규모 5를 초과하는 지진이 발생하여 상수도관의 피해가 다수 보고된 바 있다. 따라서 국내에서도 상수도관의 지진에 대한 대비가 필요 할 것으로 판단된다. 상수도관은 상수도 공급시스템에 있어 혈관과도 같은 중요한 시설로서 다양한 규격과 재질의 배관으로 구성된다. 그러므로 지진에 의한 상수도관의 손상은 식수공급, 화 재진압 등의 문제를 일으키게 되며, 인명 및 재산피해를 유발하게 된다. 하지만 국내에서는 시험 검증 및 경험에 의해 매립상수도관의 내진 성능이 평가된 예를 찾아보기 어렵다. 지진에 의한 상수도관의 손상은 액상화와 단층과 같은 지반의 변위지배적인 거동으로 인하여 발생한다. 지진에 의한 상수도관의 주된 파손은 배관 이음부에 집중되며 특히 직경 200mm 이하 배관이 위험한 것으로 조사되었다. 따라서 본 연구에서는 호칭 150mm의 클램프로 고정된 이음을 가지는 iPVC 매립 상수도관에 대하여 시험적인 접근으로 내진 성능 및 내침하 성능을 평가 하였다.