검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For this study, we established a system for the CPU cooling performance evaluation and conducted performance tests on air-cooling and water-cooling to understand the effect of the CPU cooling method on performance. For the performance evaluation, the test chamber and water-cooling system were set up, the workload S/W was selected, and a case file was created. In the case of the air-cooling, the CPU temperature is sensitively affected by the outside air temperature, the direction of the board installation, and the influence of the airflow formed around it, and may cause a lot of fluctuations in the CPU temperature. When the water-cooling system was applied, the CPU temperature decreased from 75℃℃ to 37℃ compared to the air-cooled type under the test conditions of 28.5℃ and 3LPM cooling water supply temperature and flow rate. As the CPU clock speed increased due to the decrease in temperature, it was found that the job execution time was reduced by 15~23%. In the future, it is expected that using this performance evaluation environment established through this study will enable us to easily conduct test evaluations for various processors, cooling methods, and changes in operating conditions.
        4,200원
        2.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to analyze the temperature and heat resistance distribution, which is a criterion for evaluating the cooling performance, by using computer simulation of the cooling system combined with the CPU of the individual highest heat generation section, and use it as important data for the heat sink design. Using a single material of Al 6063-T5, which is an integral part of the desktop, fan and heat sink, fins and base, the analysis was carried out with various fin numbers, thicknesses, pitches and shapes of heat sinks. Ambient temperature, 25°C, heat source, 130W and cooling fan speed, 2500 rpm (50CFM) were used as boundary conditions, and heat transfer characteristics regarding temperature distribution and heat resistance were investigated using ANSYS Icepak. As a result, it has been found that as the number of fins of heat sink increases, the heat dissipation area increases to decrease heat resistance, and as the distance between each fin decreases, the ventilation resistance increases to decrease the flow intensity of the cooling air in contact with the heat dissipation area. The sunburst array also exhibits better heat transfer characteristics by obtaining a lower distribution of heat resistance with a cooling effect of about 10°C than the one-way basic array.
        4,000원