        1.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the “Clinometer + bubble level”, a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at 90° abduction; ER90 and internal rotation at 90° abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75∼.87] and excellent in ER90 [ICC (2,1)=.90∼.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.
        4,300원
        2.
        2013.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurement of the psoas major (PM) using ultrasonography (US) conducted at different inward pressures of approximately .5 ㎏, 1.0 ㎏, 1.5 ㎏, and 2.0 ㎏. Twelve healthy male subjects were recruited for the study. The thicknesses of both PMs of each subject were measured by two different examiners in a random manner to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability and ICC (3,1) was used to assess the intra-rater reliability of the MT measurement of the PM. The results indicated higher ICC values for intra-rater reliability compared to inter-rater reliability. In addition, the value for intra-rater reliability with .5 ㎏ inward pressure [ICC=.99 (95%CI=.98∼.99)] was higher compared to 1.0 ㎏, 1.5 ㎏, and 2.0 ㎏. Other inward pressures for intra- and inter-rater reliability in current study were also demonstrated to have excellent values (ICC=.94∼.99). These findings showed that maintaining consistent inward pressure is essential for maintaining reliability of the results when the MT of the PM is measured by different examiners in a clinical setting.
        4,000원
        3.
        2012.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ely's test is commonly used to assess rectus femoris muscle flexibility. however, a reliability limit of this test was demonstrated by a previous study. In this study, we present an alternative method using an application for a digital horizontal level in a smartphone (DHLS) to complement the reliability limit of Ely's test. The aim of this study was to examine the reliability of Ely's test using DHLS on the pelvis, compared to using visual observation (VO) of pelvic and hip motions. Nineteen patients with lumbar extension-rotation syndrome were recruited for this study. An examiner examined the rectus femoris flexibility (both pass/fail and goniometer scoring) through Ely's test using both DHLS and VO. A retest session was completed two hours later for within-day reliability and seven days later for between-day intra-rater test-retest reliability. Results showed higher Kappa values for pass/fail scoring and higher intraclass correlation coefficient values for goniometer scoring in Ely's test using DHLS, compared to using VO. Measurement error and Bland and Altman plots further demonstrated the degree of intra-rater variance during Ely's test using DHLS in a clinical setting, compared to using VO. These results demonstrated that Ely's test using DHLS showed acceptable reliability compared to using VO. Ely's test using DHLS could be widely used for measuring the rectus femoris muscle flexibility in patients with lumbar extension-rotation syndrome, although the inter-rater reliability needs to be established first.
        4,000원
        4.
        2007.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Muscle tone (stiffness/hardness) or muscle compliance changes during muscle contraction. The purposes of this study were to assess the intrarater and interrater reliabilities of the Myotonometer®, electronic device that quantifies muscle tone. Two raters used the Myotonometer to assess the right bicep brachia and quadriceps muscles of 30 voluntary persons without any orthopedic or neurological problems (age range, 18~21 yrs). Muscles were measured in a relaxed state and during brief sustained voluntary maximal isometric contraction. Intrarater correlation coefficients were calculated for each muscle and for each condition (relaxed and contracted). Intrarater reliabilities (intraclass correlation coefficients, ICCs) ranged from .778 to .954, relaxed, biceps brachia), .926 to .963 (contracted, biceps brachia), .935 to .990 (relaxed, quadriceps) and .679 to .952(contracted, quadriceps). Interrater reliabilities ranged from .652 to .790 (relaxed, biceps brachii), .813 to .907 (contracted, biceps brachii), .831 to .950 (relaxed, quadriceps) and .849 to .937 (contracted, quadriceps). Myotonometer measurements had high to very high intrarater and interrater reliability for measurements of the biceps brachia and quadriceps muscles.
        4,000원
        5.
        2005.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, 20.4±2.2 yrs; height, 164.0±5.5 ㎝; weight, 58.7±7.3 ㎏) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.
        4,000원
        6.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, sitting balance is decreased in subjects with spinal cord injury. The purpose of this study was to evaluate the inter- and intra-rater reliability of the Functional Reach Test (FRT) which is used to measure sitting balance. The subjects of this study were 26 persons with spinal cord injury, and they were divided into three groups according to their injury level. Group I, II and III consisted of the following quadriplegics, , and paraplegics, respectively. Subjects sat on a mat table that was set at an 80 degree inclination. During three sessions, the length subjects could reach in the FRT test was measured by three physical therapists, and compared to each other. The results showed that intraclass correlation coefficients (2,1) were above 0.97 and inter-rater difference was not statistically significant. The one-way ANOVA demonstrated that reach differed between groups with lower thoracic lesion and the other test groups. In conclusion, we think modified FRT is useful and reliable method to measure the sitting balance in subjects with spinal cord injury.
        4,000원