Structures of high-rise buildings are less prone to earthquake damage. This is because the response acceleration of high-rise buildings appears to be small by generally occurring short-period ground motions. However, due to the increased construction volume of high-rise buildings and concerns about large earthquakes, long-period ground motions have begun to be recognized as a risk factor for high-rise buildings. Ground motion observed on each floor of the building is affected by the eigenmode of the building because the ground motion input to the building is amplified in the frequency range corresponding to the building's natural frequency. In addition, long-period components of ground motion are more easily transmitted to the floor or attached components of the building than short-period components. As such, high-rise buildings and non-structural components pose concerns about long-period ground motion. However, the criteria (ASCE 7-22) underestimate the acceleration response of buildings and non-structural components caused by long-period ground motion. Therefore, the characteristics of buildings’ acceleration response amplification ratio and non-structural components were reviewed in this study through shake table tests considering long-period ground motions.
In the event of an earthquake, non-structural components require seismic performance to ensure evacuation routes and to protect lives from falling non-structural components. Accordingly, the seismic design code proposes horizontal force for the design and evaluation of non-structural components. Ground motion observed on each floor is affected by a building's eigen vibration mode. Therefore, the earthquake damage of non-structural components is determined by the characteristics of the non-structural component system and the vibration characteristics of the building. Floor response spectra in the seismic design code are estimated through time history analysis using seismic waves. However, it is difficult to use floor response spectra as a design criterion because of user-specific uncertainties of time history analysis. In addition, considering the response characteristics of high-rise buildings to long-period ground motions, the safety factor of the proposed horizontal force may be low. Therefore, this study carried out the horizontal force review proposed in the seismic design code through dynamic analysis and evaluated the floor response of seismic waves considering buildings and predominant periods of seismic waves.
The seismic damage of non-structural components, such as communication facilities, causes direct economic losses as well as indirect losses which result from social chaos occurring with downtime of communication and financial management network systems. The current Korean seismic code, KBC2009, prescribes the design criteria and requirements of non-structural components based on their elastic response. However, it is difficult for KBC to reflect the dynamic characteristics of structures where non-structural components exist. In this study, both linear and nonlinear time history analyses of structures with various analysis parameters were carried out and floor acceleration spectra obtained from analyses were compared with both ground acceleration spectra used for input records of the analyses and the design floor acceleration spectrum proposed by National Radio Research Agency. Also, this study investigates to find out the influence of structural dynamic characteristics on the floor acceleration spectra. The analysis results show that the acceleration amplification is observed due to the resonance phenomenon and such amplification increases with the increase of building heights and with the decrease of structure’s energy dissipation capacities.
후설치앵커는 굳은 콘크리트 부재에 설치되어 구조 부재간의 하중 전달 또는 비구조요소의 하중을 구조부재로 전달하는데 사용된다. 국내 후설치앵커는 2007년 콘크리트구조기준 개정에 처음 신설되었으며 기계식 후설치앵커의 설계법만 규정하였다. 2018년 10월 기준 개정에서는 부착식 후설치앵커 설계법도 추가되었으며 특히 부록에서 본문 22장으로 이동하였다. 2020 년 국가건설기준으로 반영되면 법적 기준의 지위를 갖게된다. 내진보강, 구조보강, 증축 및 리모델링을 비로한 구조 요소간 접합뿐 아니라 기계전기설비와 마감재 등 비구조요소를 구조부재에 연결에도 후설치앵커가 많이 사용된다. 이 연구에서는 구조기준의 개정사항을 분석하여 안전하고 경제적인 후설치앵커 설계방법을 제시하고자 한다.
세계적으로 지진과 같은 자연재해로 인한 대규모 피해가 증가하고 있다. 다양한 연구를 통하여 건물에 대한 내진성능은 확보되었으나, 비구조요소의 내진성능 확보 미흡으로 인하여 인명 피해 및 경제적 손실이 발생하고 있다. 비구조요소는 구조물에 설치되는 위치가 다양하고, 구조물의 위치에 따라 발생하는 진동특성이 다르므로 구조물의 위치별 응답스펙트럼이 필요하다. 또한 구조물의 형식과 구조물이 설치되는 위치에 따라 구조물에 발생하는 응답스펙트럼이 다르게 발생한다. 따라서 응답스펙트럼의 선정이 중요하므로 비구조요소에 작용하는 응답스펙트럼을 도출할 수 있는 명확한 방법이 필요하다. 본 논문에서는 응답스펙트럼을 도출하는 방법을 제안하였으며, 제안한 방법으로 국내에서 발생 가능한 지반응답스펙트럼과 구조시스템을 선정하여 구조해석을 수행하였다. 또한, 간단한 수식으로 응답스펙트럼을 도출하는 방법을 제안함으로서, 비구조요소의 내진시험에 필요한 응답스펙트럼을 생성할 수 있도록 하였다.
In this study, Long-period component seismic wave is determined to a large damage of the non-structural material as compared to the structure damage when it is input to high-rise buildings, which allows to perform a vibration table test, was evaluated for damage or loss of the non-structural material.