검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most of the odorous substances generated in public environment facilities are treated using a local exhaust ventilation system. This study assessed the leakage of odorous substances by measuring design criteria, collected air volume, and complex odor in the unit process of sewage treatment facilities. The closer the guideline/design operation airflow ratio of each odor source is to 1.0, the more identical the guideline:design:operation airflow. The average air volume ratio of the facilities under the study was 0.95~0.99 for the MBR process and 0.29~0.68 for the BNR process. As a result of comparing the types of wastewater treatment processes, the leakage of odorous substances was about 9.7 times higher in the BNR process (192,732 m3/min) than in the MBR process (19,838 m3/ min). In this study, it was found that the following two means are important for the proper collection and prevention of odorous substances. The first is the estimation of collection air volume with consideration to the characteristics of the odor source (temperature, odor generation condition, etc.). The second is the design and operation of the local exhaust ventilation system.
        4,000원
        3.
        2014.11 KCI 등재 서비스 종료(열람 제한)
        Increasing public concerns over odors and air regulations necessitates the remediation of a wide range of odor substances for industrial and indoor purpose. Currently, the wet scrubbing technique by neutralization using oils is being used to treat odor substances such as Ammonia(NH3), Methyl Mercaptan(CH3SH), Hydrogen Sulfide(H2S), Methylamine(CH3NH2), Acetaldehyde(CH3CHO). The chemical analysis is performed to analyze the composition of an Arctium Lappa Root extract by VOC analyzer(Phocheck 5000Ex, ION SCIENCE co.) The objectives of the this study are to clarify the possibility of the neutralization of odors sprayed in the fixed bed and determine the removal efficiencies for different input odor concentrations. It is found that Ammonia(NH3), Methyl Mercaptan(CH3SH), Hydrogen Sulfide(H2S), Methylamine(CH3NH2), Acetaldehyde(CH3CHO) are significantly removed and their removal efficiencies are higher than 98%. The kitchen detergent with Arctium Lappa Root extract showed excellent removal efficiencies of odor substances and high possibility for the development of kitchen detergent with odor removal.
        4.
        2008.05 KCI 등재 서비스 종료(열람 제한)
        5 public complaint areas against odor in Changwon Industrial Complex were selected and investigated to clear up the cause of the complaint. 16 companies operated in public complaint areas were visited and had a grip of their situation about odor generation and treatment. Two samples at it's site boundary of each company were taken to measure complex odor unit. Complex odor unit at the site boundary of investigated companies in the public complaint areas, for the most part, exceeded standard(odor unit 20) in industrial area. It was due to that this area was not designated as odor control region and that there are also many problems in current laws of Odor Protection Act, Air Quality Act and regional legislation. Accordingly, It will be necessary to revise the related legislation, to organize governance, to financially support the improvement of environmental facilities and to enforce guidance and the regulation rigidly for the odor emission reduction in Changwon Industrial Complex.