A timber lattice roof, which has around 30m span, was constructed. In order to figure out the realistic buckling load level, the structural analysis of this roof structure was performed especially by stiffness of connection with various asymmetric snow load. Due to the characteristics of application of snow load, the load combinations of snow should be considered not only global area but also local part so that the critical buckling load could be observed as easy as possible. Geometrical imperfection was simulated to consider inaccurate shape of structure. And then nonlinear analysis were performed. Finally, this paper could investigate that the asymmetric snow load with the lower level stiffness of connection decreased the level of buckling load significantly.
본 연구에서는 적설하중 산정을 위한 노출계수를 결정 하는데 필요한 기초자료를 제공하기 위하여 각국의 온실 구조설계기준에서 제시된 노출계수들을 비교분석하였고 우리나라의 각 지역별 노출계수를 결정하고 결정방법에 대하여 개선방안을 분석하였으며 연구결과를 요약하면 다음과 같다. 각국의 노출계수 기준을 비교분석한 결과 노출계수에 영향을 미치는 주요인자는 노풍도, 풍속, 바람막이의 유무인 것으로 분석되었다. 또한 일본을 제외한 각국의 기 준을 종합하면 노출계수는 3가지 단계로 구분되며 바람에 완전히 노출되고 바람이 센 지역의 노출계수는 0.8(0.9), 바람에 부분적으로 노출된 지역은 1.0(1.1), 바람 막이가 조밀하게 설치된 지역은 1.2로 나타낼 수 있다. 따라서 온실의 적설하중 산정을 위한 노출계수는 적용의 용이성을 고려한다면 3단계로 구분하여 제시하는 것이 바람직할 것으로 판단된다. ISO 4355기준에 따라 우리 나라 94개 지역에 대한 노출계수를 산정한 결과 대관령 (0.5)과 여수(0.6)를 제외한 모든 지역의 노출계수가 1.0 과 0.8 두 가지로 대별되었다. 우리나라의 내륙지역이 해안지역에 비해 상대적으로 더 큰 강설 확률을 가지며 최대풍속이 5m·s-1 이상인 일수가 더 작은 것으로 분석되 었다. 우리나라의 노출계수는 3단계로 구분하여 해안 지역을 중심으로 한 바람이 강한 지역을 0.8로 하고 내륙 지역은 1.0으로 하며 촘촘한 바람막이가 있는 경우는 일본을 제외한 각국에서 적용하고 있는 값인 1.2로 결정하 는 것이 바람직할 것으로 판단되며, 임계풍속 5.0m·s-1 이상 일 수에 따른 지역별 구체적인 노출계수는 추가적인 연구를 통해 결정할 필요가 있다.
A single-layerd steel lattice roof, which has 50m span, was constructed. In order to figure out the realistic buckling load level, the structural analysis of this roof structure was performed especially by local snow load. Due to the characteristics of application of snow load, the load combinations of snow should be considered not only global area but also local part so that the critical buckling load could be observed as easy as possible. Geometrical imperfection was simulated to consider inaccurate shape of structure. And then nonlinear analysis were performed. Finally, this paper could investigate that the local snow load with geometrical imperfection decreased the level of buckling load significantly.
This study analyzed load transferred from upper structure due to wind and snow loads and applied to foundation on greenhouse structure in order to provide basic data for economic and reasonable design of greenhouse. The results indicate that the upper structures of greenhouses in Korea take wind load of 18.2-121.5 kgff/m2 and snow load of 3.1-104.6 kgff/m2. The maximum compressive load from axial direction applied on the foundation of greenhouse subjected to facility and crop loads was 437 kgff. The maximum pull-out load applied on the foundation of greenhouse subjected to wind load was 1557 kgff. The maximum compressive load applied on the foundation of greenhouse subjected to snow load was 6094 kgff.
산업화 및 도시화의 급속한 진전에 따라 도시통행량이 증가하고 있으며, 이러한 도시교통의 양상은 짧은 시간내에 많은 양의 눈이 내리면서 교통혼잡과 극심한 정체로 이어져 심각한 교통대란을 야기시키기도 한다. 이처럼 강설시의 원할한 통행을 도모하기 위한 방안의 하나로서, 도로의 구조 및 도로상의 다양한 위험요소들이 강설시의 차량통행에 어떠한 영향을 끼치는지에 대한 분석이 필요한 시점이며, 이를 위해 본 연구에서는 강설시 도로위험구간을 도출하기 위한 분석틀의 설정 및 중요도분석을 통해 보다 객관화된 지표를 선정하고자 하였다.
본 연구에서는, 1)평가지표의 개발을 위해 표적집단면접(FGI) 및 전문가 브레인 스토밍을 거쳐 최종 평가지표(지리·지형특성, 도로시설, 도로기하구조, 교통특성)를 도출하였으며, 2)도출된 평가지표들을 토대로 AHP분석을 실시하여 각 평가항목별 가중치를 산정하였다. 본 연구의 결과, 평가항목 측면에서 보면, 4가지 평가지표 중 교통특성이 강설도로 위험구간 선정시 가장 중요한 항목으로 도출되었는데, 이는 일반적인 시설이나 지리적인 특성보다는 강설시 가장 위험한 것이 교통량이나 대형차와 같은 교통적인 특성이라는 것으로 판단할 수 있다.