검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 299

        81.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently, the cutting oil supply device is not equipped to cool the cutting oil. Therefore, additional cooling device should be connected to cool the cutting oil. This has the disadvantage of increasing the size of the device and reducing its cooling capability. To overcome these shortcomings, cooling coils are applied to the outside of the cutting oil filtering device to develop a heat exchanger filter for simultaneous coolant filtering and cooling to improve the compactness of the cutting oil supply device and cooling capability of the cutting oil. For the development of heat exchanger filter, flow and heat transfer analysis were performed. Due to the small heat transfer area of 10 cooling coils, less heat exchange occurred. In the 20 cooling coils, the coolant cooling coils prevented smooth flow of the cooling oil in the heat exchanger filter. The cooling efficiency of the 15 cooling coils were best, and the cooling temperature decreased non-linearly as the supply flow rate of the cutting oil increased.
        4,000원
        82.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실 냉난방시스템 설계용 외부기상조건의 분석 기준을 설정하기 위하여 연간 백분위 방식에 의한 냉난방 설계기온을 분석하고, 기존의 계절 백분위 방식에 의한 설계기온과 비교 검토하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상 데이터의 이용이 제한적이기 때문에 전체 기상자료를 이용하여 매년 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 분석에 사용하였다. 연간 백분위 방식으로 1년 기준 총 8,760시간의 백분위수 0.4%, 1%, 2%를 냉방 설계 외기온으로, 99.6%, 99%를 난방 설계 외기온으로 제시하였다. 연간 백분위 방식을 채택할 경우 계절 백분위 방식에 비하여 전체적으로 난방설계 외기온은 6.7~9.6% 상승하는 것으로 나타났으며, 냉방설계 외기온은 0.6~1.1% 하강하는 것으로 나타났다. 동일한 온실 조건에서 최대난방부하는 연간 백분위 방식을 채택할 경우 기존의 계절 백분위 방식에 비하여 약 3.0~3.6% 정도 감소하는 것으로 나타났고, 최대냉방부하에 미치는 영향은 미미한 것으로 분석되었다. 따라서 난방설계 외기온은 연간 백분위 방식으로의 변경에 대하여 고려할 필요가 있지만, 냉방설계 외기온은 두 방법 간의 차이가 거의 없으므로 아직까지 변경할 필요는 없는 것으로 판단된다. 전체적으로 현재의 계절 백분위 방식으로 분석한 설계 외기온을 사용하여도 큰 문제는 없을 것으로 생각되지만, 기후변화의 영향을 고려하여 주기적인 설계용 기상자료의 분석 및 설계기준의 개정이 필요하고, 현재의 기후평년값 기준연도가 바뀌는 2021년 이후에는 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것이므로, 그 때 연간 백분위 방식에 대한 전문가 그룹의 검토를 통하여 반영할 필요가 있을 것으로 판단된다.
        4,000원
        84.
        2018.04 구독 인증기관·개인회원 무료
        전 세계적으로 기후변화에 따른 기온 상승의 문제가 심각 해지고 있으며, 특히 폭염, 열대야와 같은 도시 열환경에 대한 문제가 사회적으로 크게 대두되었다. 이에 따라 건축 및 도시계획, 조경 및 환경설계, 대기환경 등 다양한 분야에서 도시 열환경 개선을 위해 방안을 제시하고 있다. 그 중에서도 정맥의 숲에서 야간에 생성되는 차고 신선한 공기는 지형을 따라 도시로 유입되어 폭염 및 열대야를 완화시키는 중요한 역할을 한다. 찬공기를 활용해 열환경을 개선하기 위해서는 찬공기 생성지역 및 이동통로에 대한 분석과 함께 찬공기의 흐름을 도시로 유입하는 전략이 필요하다. 따라서 본 연구에서는 한남금북·금북정맥 일대를 사례로 산지의 지형적 특성 및 토지 이용에 따라 야간에 생성되는 찬공기 흐름에 대한 특징을 분석하고, 야간기온 저감효과를 관리하 기 위한 방안을 마련하였다. 사례지역인 한남금북·금북정맥 일대의 전반적인 찬공기 생성정도를 파악하고자 정맥의 약 86%(298.6km)를 포함하는 120km x 80km로 분석범위를 설정하였다. 또한 정맥을 지나는 지역 중 도심지 부근에 형성되어 있으며, 분지지형 으로써 도시 열환경 문제가 더욱 심각해질 것으로 예상되는 청주시를 대상(분석범위: 45km x 45km)으로 상세 분석을 실시하였다.정맥에서 생성되는 찬공기의 특성을 분석 하기 위해서 광범위한 지역 분석시 적합한 모형인 KALM (Kaltluftabflussmodell)을 활용하였다. 독일에서 개발된 KALM은 일출 후부터 일출 전까지의 야간 6시간 동안의 시간별(60min, 120min, 180min, 240min, 300min, 360min) 찬공기 흐름 및 찬공기 층 높이를 산정하며, 입력자료로는 지형자료와 토지이용자료가 이용된다. 본 연구에서는 환경 부에서 제공하는 중분류 토지피복도 22개의 유형을 7개 유형(Suburb, Forest, Open land, City center, Water, Traffic area, Industrial area)으로 재분류하여 사용했으며, 정맥의 전체 대상지로 분석 시 해상도를 200m, 청주시를 대상으로 는 90m로 설정하였다. 정맥에서 생성된 야간의 찬공기 흐름은 시간이 지남에 따라 더욱 강해지고, 찬공기 층 높이 또한 계곡지형과 농경지를 중심으로 두껍게 발달하였다. 한남금북·금북정맥 일대 는 약 0.5m의 찬공기가 평균적으로 흘렀고, 최대 2.5m/s 이상의 흐름이 나타났다. 정맥에 위치한 산 중 칠장산(해발 고도: 491.2m), 가야산(해발고도: 677.6m), 봉수산(해발고 도: 534m), 좌구산(해발고도: 657.8m)에서 생성된 찬공기가 인근 지역으로 가장 강하게 흘렀다. 특히 칠장산에서 생 성된 찬공기는 안성시의 대규모 농경지 및 안성천을 따라 서쪽으로 강하게 흘러 들어갔으며, 안성시청이 위치한 중심 지를 지나 평택시까지 영향을 미치고 있었다. 이 흐름은 다 시 평택시의 농경지 및 아산만을 거쳐 남쪽에 있는 당진시, 아산시 등 충청남도 지역까지 흐르는 모습이 나타났다. 가야산 인근에서 생성된 찬공기는 예산군 및 서산시를 중심으로 흘러 농경지를 지나면서 점차 발달했고, 봉수산 인근에서 생성된 찬공기는 예산군 및 공주시에 영향을 미쳤다. 좌구산의 경우 인근에 위치한 청주시의 바람흐름에 중요한 역할을 하고 있었다. 행정구역별 찬공기 층 높이를 비교한 결과, 6시간 평균 기준 찬공기 층 높이의 평균값은 진천군, 보은군, 청주시, 예산군, 공주시, 세종특별자치시에서 높게 나타났고, 최대값은 진천군, 공주시, 괴산군에서 관찰되었다. 청주시를 상세 분석한 결과는 다음과 같다. 동쪽에 위치 한 한남금북정맥에서 생성된 찬공기가 청주시로 유입되는 것을 자세히 확인 할 수 있었다. 행정구역별로는 6시간 평균을 기준으로, 찬공기 흐름의 평균값은 상당구와 서원구에서 높게 나타났으며, 최대값 또한 상당구에서 높았다. 이는 한 남금북정맥이 상당구에 위치해 있어 계곡 지형과 같은 찬공기 발달에 유리한 지형이 많이 분포하고 있기 때문이다. 찬 공기 층 높이의 경우 역시 높은 산지의 골짜기를 따라 찬공기 층이 높게 쌓이는 지형적 특성으로 인해 상당구에서 최대값이 나타났지만, 평균값은 농경지 등 평지 지형이 주를 이루는 흥덕구와 청원구에서 높게 나타났다. 이는 지형적 특성상 낮은 찬공기 층이 넓게 분포되어 있기 때문이다. 주요 흐름은 크게 세 가지로 관찰되었다. 먼저 좌구산 일대 의 골짜기를 따라 발달한 찬공기가 청원구로 강하게 흘러들 어 갔는데, 골짜기 하단에 위치한 저수지(상기저수지, 연평 저수지, 비홍저수지)로 인해 그 흐름이 더욱 뚜렷해졌다. 다음으로 정맥에 포함되는 망산, 갓대산, 낙기산, 선도산 일 대에서 생성된 찬공기는 청주시의 중심시가지로 유입되어 무심천과 합류 후 남쪽으로 강한 흐름을 만들어 내고 있었다. 하지만 청주일반산업단지 지역에서는 그 흐름이 약해지고 있었다. 마지막으로 좌구산 및 망산에서 생성된 찬공기가 흥덕구까지 원활한 흐름으로 이어지고 있었다. 흥덕구 일원에는 기존 농경지 자리에 개발단지들이 위치해 있는데, 그 중 오송역세권 도시개발구역은 바람 흐름이 좋은 곳에 위치해 있어 개발구역내 쾌적한 열환경이 기대되었다. 하지만 일반공업단지인 오송국가산업단지와 개발이 예정되어 있는 오송바이오폴리스지구는 찬공기 흐름이 원활하지 못 한 것으로 분석되었다. 정맥의 기온저감 효과를 검증하기 위해서 기상청에서 운영하는 자동기상관측소(AWS) 및 종관기상관측장비(ASOS) 의 관측값을 활용하여 청주시 내의 야간기온저감 정도를 비교하였다. 청주시의 대표 기상을 관측하는 4곳(청주기상대, 우암산, 상당 청남대)을 비교한 결과, 정맥과 가장 가까 이에 위치한 상당(11.77℃)에서 기온저감 효과가 가장 컸으 며, 청남대(9.49℃), 우암산(7.92℃), 청주기상대(7.81℃) 순으로 나타났다. 청주기상대의 경우 공업지역 부근에 위치해 있어, 찬공기의 흐름이 원활했던 청주시가지에 비해 기온저감 효과가 가장 낮은 것으로 판단되었다. 이에 따라 정 맥에서 야간에 생성된 찬공기가 청주시의 기온저감에 영향을 미친 것을 확인할 수 있었다. 분석결과를 바탕으로 정맥의 관리방안을 제시하였다. 한 남금북·금북정맥 일대에 위치한 산 중 칠장산, 태조산, 좌구산, 봉수산 일대는 차고 신선한 공기의 생성 지역이므로 현재의 온도조절 기능 유지를 위해 보전되어야 한다. 특히 칠 장산 일대는 정맥 전체의 원활한 찬공기 흐름을 위한 가장 중요한 근원지이므로 반드시 개발로부터 보전되어야 한다. 또한 영인산 일대는 정맥에 포함되지는 않지만 칠장산 일대 에서 생성된 찬공기와 합류하여 충청남도에 유입되는 흐름 을 확대시키는 지역으로써 정맥의 기능을 보완하도록 해야 한다. 한남금북정맥의 일대(좌구산, 망산 등)에서 발원된 찬 공기 흐름은 청주시의 중심 시가지 및 전역으로 원활하게 유입됨으로써 야간 열환경 개선에 긍정적인 영향을 미치고 있었다. 따라서 청주시의 기온조절 잠재력의 근원지역으로 써 보전계획을 수립해야 한다. 본 연구의 결과는 한남금북· 금북정맥 일대에 위치한 지역의 열환경 개선을 위한 체계적인 관리계획을 수립하는데 활용될 수 있을 것이며, 정맥의 야간기온 저감효과를 확대할 수 있는 관련 정책 마련을 위한 기초자료로 활용 될 수 있을 것이다.
        85.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        송국리문화의 핵심적 요소인 송국리형주거지는 알려진 바와 같이 내부시설로서 爐가 확인되지 않는 매우 특이한 주거형태이다. 이러한 노부재에 대한 의견은 구체적인 형태는 알 수 없지만 노가 존재하였다는 ‘노존재설’과 노가 주거지시설에서 사라지거나 야외로 이동했다고 보는 ‘노부재설’로 크게 나누어 진다. 필자는 후자의 입장에서 송국리형주거지의 발생으로 대표되는 송국리문화의 발생 원인으로는 청동 기시대 기원전 10세기 이후 중기 한랭화라는 기후변화와 관련성이 있는 것으로 판단한다. 기온의 하강은 생계에 있어서는 농경에 대한 집중력을 높이고, 생활에 있어서는 주거규모를 축소함과 동시에 주거지 내부의 노를 외부로 이동하는 대신 공동취사를 통해 조직의 효율성을 높이려 했다. 상대적으로 잔존상태가 양호한 영남지방 충적지취락의 사례로 살펴볼 때, 노는 주거와 일대일이 아닌 공동취사를 위한 일정한 곳에 밀집된 방식으로 운영하였음이 그 증거이다. 이렇게 주거내 노를 제거한 상태에서 겨울 추위에 대한 대비로 일부지역의 경우 주거지의 깊이를 깊게 하는 방식으로 해결하려 한 행위도 확인된다. 청동기시대 중기 송국리문화라는 새로운 문화가 출현하게 된 배경에는 기후변화라는 현실적인 환경적 변화가 직면하여 당시인들은 주거 내부에서 노를 과감하게 외부로 이동시킨 송국리형주거로서 위기를 극복하려고 하였다.
        6,100원
        86.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Energy saving in household refrigerators becomes more important as the usage of household refrigerators have been increasing every year. Since a compressor in the refrigerator consumes more than 80% of its total energy, it is necessary to reduce the energy consumption of the compressor. In this paper, the convective heat transfer coefficients on the compressor housing for both natural convection and forced convection were measured. Then, the effect of convective heat transfer coefficient on the power consumption of a refrigerator was investigated using a thermal management analysis. The results showed that convective heat transfer coefficient for forced convection is higher by 7.8 W/m²K compared to the natural convection. In addition, through the thermal management analysis, it was found that the increase in convective heat transfer coefficient reduces the refrigerator power by about 4.8% improving EER by 0.9%.
        4,000원
        87.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 적정 패널 설치 면적을 도출하기 위하여 BES 기법을 이용하여 온실 및 PV 시스템의 에너지 모델을 설계하였으며 동적 에너지 시뮬레이션을 수행하였다. 대상 작물은 파프리카로 선정하였으며 작물의 적정생육온도를 고려하여 냉·난방장치 및 환기장치의 가동조건을 설정하였다. 2012년부터 2016년까지 총 5년 동안의 기간별 냉·난방부하 및 최대 냉·난방 부하를 환 기팬의 환기량 조건 별로 분석을 실시하였다. 온실의 냉 ·난방 부하 산정과 함께 PV 시스템의 설치 각도에 따른 전력 생산량을 분석하였으며 신재생에너지 공급의무비율을 적용하여 최적 PV 시스템 설계 방안을 도출하였다. 환기팬의 환기량 60AE·hr-1 조건에서 대상 온실의 기간 평균 냉방 부하로 인한 전력 소모량은 174,310kWh, 기간 평균 난방 부하로 인한 전력 소모량은 458,903kWh 로 총 633,213kWh의 전력 소모량이 산정되었다. PV 시스템은 설치 각도를 30o로 설정하는 조건에서 가장 높은 전력 생산량이 나타났으며 월별 최적 각도를 적용하는 조건에서는 고정형 PV 시스템보다 약 5.7% 많은 전력 을 생산하는 것으론 산정 되었다. 최종적으로 대상 온실에 적합한 PV 시스템 패널 면적을 도출한 결과, 고정형 PV 시스템은 521m2의 패널이 필요한 것으로 산정되었고, 가변형 PV 시스템의 경우 494m2의 패널이 필요한 것으로 산정되었다. 본 연구를 통하여 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 필요 패널 설치 면적을 도출할 수 있었으며 PV 시스템의 온실 적용 가능성 및 경 제성 평가의 기초 자료로 활용 가능할 것으로 판단된다. 한편, 본 연구에서는 작물 특성 데이터를 확보하지 못하여 작물의 에너지 교환을 고려하지 않았다. 보다 정확한 결과를 도출하기 위해서는 현장 실험 데이터에 기반을 둔 추가 연구가 필요할 것으로 판단된다.
        4,000원
        88.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Air-shiter is a new product possible ventilation at the same time cooling or heating with combined refrigerator and heat recovery ventilator. And a key device of this system is the air shifter. The air shifter device is to convert the outdoor air, room air, supply air and exhaust air flow. Therefore, an experimental study has been carried out to investigate the operating performance for this system. The results, it is possible to ventilate at the same time of heating by outside air above 30℃ in summer. and of heating by outside air within 3℃ in winter. The indoor discharge temperature is over 40℃, and the coefficient of performance is 3.4 in winter.
        4,000원
        90.
        2017.11 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In the present study the microstructure of low-carbon steels fabricated by controlled rolling and accelerated cooling processes was characterized and identified based on various microstructure analysis methods including optical and scanning electron microscopy, and electron backscatter diffraction(EBSD). Although low-carbon steels are usually composed of α-ferrite and cementite(Fe3C) phases, they can have complex microstructures consisting of ferrites with different size, morphology, and dislocation density, and secondary phases dependent on rolling and accelerated cooling conditions. The microstructure of lowcarbon steels investigated in this study was basically classified into polygonal ferrite, acicular ferrite, granular bainite, and bainitic ferrite based on the inverse pole figure, image quality, grain boundary, kernel average misorientation(KAM), and grain orientation spread(GOS) maps, obtained from EBSD analysis. From these results, it can be said that the EBSD analysis provides a valuable tool to identify and quantify the complex microstructure of low-carbon steels fabricated by controlled rolling and accelerated cooling processes.
        4,000원
        91.
        2017.11 구독 인증기관 무료, 개인회원 유료
        For years, many beauty industries have been developed many beauty treatment machines in healthcare. It is respond to increased demand for new health technologies aimed at assisting aging populations, promoting public health, and improving quality of life. The purpose of this study was to develop the cooling treatment machine to be operators in clinical and beauty treatment use. The developed machine can an be helpful for skin soothing treatment of skin care shop and cosmetic surgery in beauty industries.
        3,000원
        92.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although most of the automobile bodies are made of steel, the application of aluminum alloy sheet with high strength is under consideration for the development of environmentally friendly lightweight body for fuel economy improvement and carbon dioxide emission reduction. In the case of some inner plates, application of magnesium alloy sheet is examined. TRB plate has been studied mainly for weight reduction and rigidity reinforcement of steel plate parts. Recently, research on aluminum TRB rolled plate for light and environment friendly automobile application has been started, It is expected that the development of eco - friendly TRB rolling material made of light alloy will increase as the importance of light weight body for future energy efficiency increases. Therefore, in this study, we tried to obtain the technology to improve the quality of the product by pre - verifying the cooling performance of the hot forming process through the heat flow analysis and evaluating the cooling performance through the temperature distribution analysis. As a result, it was found that the temperature distribution through the flow velocity problem and the flow of the cooling channel can influence the quality of the final product through different heat distribution and cooling time depending on the shape of the mold and the product.
        4,000원
        93.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        간척지 온실의 환경설계 기술 개발을 위한 기초자료 제공을 목적으로, 첨단 시설원예단지 설치 계획이 있는 국내 7개 대규모 간척지 주변의 기후조건을 분석하였으며, 새만금 간척지 내에 설치된 3연동 플라스틱 온실을 대상으로 하절기에 시설 내외의 열적 환경계측 실험을 통하여 자연환기 및 온도 상승 특성을 분석하고, 간척지 온실의 환경 설계에 적용해야 할 부분을 검토하였다. 작물의 유무에 따른 온실의 환기율을 비교한 결과, 작물이 있으면 온실의 환기율은 낮아지지만 작물의 증발산에 의해 실내기온 상승은 감소하는 것으로 나타났다. 작물이 있는 경우 온실의 환기회수는 대체로 0.3~0.9회/min의 범위에 있었고, 평균 0.7 회/min으로 나타났다. 실외기온 대비 실내기온 상승은 1~5oC정도의 범위에 있었고, 평균 2.5oC로 나타났다. 간척지에 설치된 실험온실의 자연환기 성능은 여름철 권장 환기율을 거의 만족시키고, 실외기온 대비 실내기온 상승도 작물재배 환경을 크게 벗어나지 않으므로 새만금 간척지에서는 냉방설비 없이 자연환기 만으로 온실의 작물 재배가 가능할 것으로 판단된다. 간척지는 해안에 위치하고 있어 내륙지역에 비하여 바람이 강하고, 안개가 자주 끼는 특성을 보이는 것으로 나타났다. 이와 같이 강한 풍속은 온실의 환기율을 증가시키므로 냉방부하의 감소요인으로 작용하게 될 것으로 판단된다. 또한 안개지속시간이 내륙지역에 비하여 현저하게 길기 때문에 기간냉방부하는 감소할 것으로 예상되며 이는 냉방 설비의 운전경비 측면에서 유리할 것으로 판단된다. 또한 간척지 온실의 환기 및 냉방시스템 설계 시에는 주변의 기상관측소 자료를 그대로 이용하지 말고, 온실 설치 지역에서 실측한 기상자료 또는 현장 여건을 반영하여 보정된 기상자료를 사용하여 설계하도록 할 필요가 있다.
        4,000원
        94.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper aims to reveal the effects of the K- turbulence model on the performance analysis of battery cooling system for electric vehicle. The maximum temperature, the difference of temperature, and temperature distributions on the battery module were compared with and without K- turbulence model under the different flow rate. It can be expected that the maximum temperature of K- turbulence model is corrected by using the average error rate without the result of K- turbulence model.
        4,000원
        95.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Warpage of injection molded product is caused by non-uniform shrinkage and residual stress. A method of removing uneven molding shrinkage and residual stress is to remove the defective factor to Uniform cooling of products. Warpages for part designs have been investigated in this study according to the injection molding conditions for amorphous ABS and crystalline PP by the rapid cooling and heating system. Experimental results showed that the crystalline resin was more warped than amorphous resin, Warpages have been observed in the regions of the part, near gate region and flow direction region.
        4,000원
        96.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cutting tools tend to wear gradually with progressing of machining process due to extremely high surface loads and temperature from the relative motions between tool and workpiece. Especially, the high cutting temperature is a dominant factor in the relation to tool life. High-pressure coolant has been reported as an effective method to prevent the severe wear from cutting temperature. This research investigates efficient supplying conditions of high-pressure coolant with the CFD results from a internal-flush drilling process. The flow rate of coolant is increased drastically up to three times under 70 bar compared to conventional way.
        4,000원
        97.
        2017.04 구독 인증기관 무료, 개인회원 유료
        This paper aims to reveal the effects of the K-ε turbulence model on the performance analysis of battery cooling system for electric vehicle. The maximum temperature, the difference of temperature, and temperature distributions on the battery module were compared with and without K- ε turbulence model under the different flow rate. It was found that there was no need to apply K-ε turbulence model when the flow rate is over 500m3/h because the difference of maximum temperature is under the 6℃.
        3,000원
        98.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The result of the previous work leads to the idea that the inner area of the hyperbolic shell generator should be minimized for the cooling tower with higher first natural frequency. In this study the inner area of the hyperbolic shell generator was graphically established under varying height of the throat and angle of the base lintel. From the graph, several shell geometries were selected and analysed in the aspect of the natural frequency. Three representative towers reinforced differently due to different first natural frequencies were analysed non-linearly and evaluated using a damage indicator based on the change of natural frequencies. The results demonstrated that the damage behaviour of the tower reinforced higher due to a lower first natural frequency was not necessarily advantageous than the others
        4,000원
        99.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 원심펌프 내부 유동장 특성에 대한 시뮬레이션 및 시각화에 중점을 둔다. 3D 수치해석은 Reynolds Average Navier-stock 코드를 k-Ɛ 표준 2차방정식 난류 모델로 처리하여 수행하였다. 시뮬레이션은 흡입측, 임펠러, 토출측 영역에서 조도로 인한 마찰 손실과 임펠러 웨어링에서 체적 손실을 포함한다. 해석과 실험사이의 성능곡선 비교결과 최대 5 %의 작은 차이를 보이며 동일한 추세를 나타냈다. 최고 효율점에서 속도 벡터는 고르게 나타났지만 비 설계점에서는 현저한 변화가 나타났고, 텅 부근의 임펠러 유로토출부에서 강력한 재순환 영역이 나타났다. 비교적 일정한 압력분포가 텅 부근임에도 불구하고 임펠러 주위에 관찰되었다. 볼류트 내에서 기하학적으로 인해 형성된 나선형 와류가 이 영역에서 유동장이 상대적으로 난류이고 불안정하다는 것을 증명하였다.
        4,000원
        100.
        2016.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        최근 국내 원전의 경수로 사용후핵연료 습식 저장시설의 포화시점이 다가옴에 따라 운반 및 저장용기를 이용한 건식저장시스템 개발이 활발하게 수행되고 있다. 일반적으로 사용후핵연료 운반 및 저장용기 설계를 위한 차폐해석 시 장전 가능 연료 중 가장 보수적인 연료를 설계기준연료로 선정하여 해석을 수행한다. 그러나 실제 금속 운반용기에 장전되는 사용후핵연료 는 해석평가에 적용된 설계기준연료에 한정되지 않고 다양하기 때문에 초기농축도, 연소도, 최소냉각기간의 특성을 고려한 차폐평가를 통하여 장전가능 여부가 결정된다. 이에 본 연구에서는 금속 겸용용기에 장전 가능한 연료를 대상으로 국내 운반기준을 만족하는 최소냉각기간의 결정을 위한 차폐해석 방법을 기술하였다. 특히 발생량이 많은 초기농축도 3.0~4.5wt% 의 사용후핵연료는 차폐해석 구간을 세분화하여 평가하여 연구결과의 활용에 효율성을 높이고자 하였다. 차폐평가를 통해 2008년까지 국내 원전에서 발생한 장전대상연료 중 약 81%의 사용후 핵연료를 금속겸용용기로 운반할 수 있는것으로 평가 되었다. 본 연구결과를 통해 금속 겸용용기의 운반조건에 장전 가능한 연료의 특성을 제시함으로써 운반 시 운영절차의 개 발을 위한 기술적 근거 수립에 도움이 되고자 한다.
        4,300원
        1 2 3 4 5