This study was carried out to investigate the effect of side vent heights on temperature and relative humidity inside and outside the single-span plastic greenhouse (W: 7 m, L: 40 m H: 3.9 m) during natural ventilation. Four different heights (120, 100, 80, 60 cm) of the side vent were used as an experimental condition. Variations of temperature and relative humidity inside and outside the greenhouse and the differences between heights were compared by using one-way ANOVA. In the daytime, the difference in temperature between inside and outside the greenhouse was dropped from 14.0°C to 7.1°C as the side vent height increased. The temperature difference in the nighttime was less than 0.2°C regardless of the height. One-way ANOVA on the temperature difference between heights presented that the statistical significance was founded between all of the combinations of height in the daytime. The difference in relative humidity between inside and outside the greenhouse was grown from –13.8% to – 22.2% with a decrease in the side vent height. The humidity difference in the nighttime was less than 1% regardless of the height. One-way ANOVA on the humidity difference revealed that most of the side vent heights showed significance in the daytime but between 100 and 80 cm was not significant. It seemed because the external air became cooler during the experiment with a height of 80 cm. Conclusively, this study empirically demonstrated that the higher side vents resulted in the decrease of differences in temperature and relative humidity between inside and outside the greenhouse, and also the effect of side vent height was statistically significant. This study may be helpful for deciding the height of the side vent effective for controlling temperature and relative humidity in a single-span greenhouse during natural ventilation.
본 연구에서는 국내에 가장 많이 보급되어 있는 1-2W 모델 연동온실에 대한 온실 규격 및 환기창 형태 실태 조사를 수행하고, 이를 바탕으로 연동온실의 천창 형태에 따른 유동 특성을 분석하기 위해 수치해석을 수행하여 자연환기효과를 분석 하고자 하였다. 온실 실태조사 대상농가의 환기창면적 비율은 평균 10%로 자연환기를 위한 시설면적 대비 환기창 면적 설계가 부족한 것으로 나타나 환기창 개선이 필요할 것으로 판단된다. 연동 온실의 천창 형태별 자연환기를 해석 및 분석한 결과, 온실 내 작물위치의 온도 분포 및 내외부 온도차는 몽골식 천창 온실에서 가장 낮고 외몽골식 천창 온실에서 가장 높게 나타났으나 추후 풍하중에 의한 구조적인 안전성을 평가 해야할 것으로 판단된다.
In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to 9.6oC depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to 0.49 min-1. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of 3.2oC and a maximum ventilation rate of 0.49 min-1.
포그냉방시스템의 냉방효과는 온실 내부의 상대습도, 공기유동과 밀접한 관계가 있다. 냉방설계용 VETH선도에서 냉발효율은 환기회수의 증가와 그에 상응하는 분무수량의 증가로 인하여 개선될 수 있다. 시간제어방식을 이용한 무차광 실험온실에서 분당 환기회수가 평균 0.77회, 분무수량이 2,009g 일 때 온실 내부의 기온이 31℃로 외부기온과 거의 같게 나타났으며, 이 때의 증발효율은 82%이다. 분당 환기회수가 평균 0.26회, 분무수량이 1.256g인 경우 무냉방 온실의 기온과 비슷한 37.1℃였다. 차광율 70%인 실험온실의 분당 환기환수가 평균 2.59회, 분무수량이 2,009g 일 때, 내부의 상대습도는 증가하나 기온은 하강하지 못했다. 그러나 분당 환기회수가 평균 2.33회, 분무수량이 2,009g인 경우 내부의 기온이 31.4℃로 이 때 온실의 유입구 풍속은 최고 1.9m.s-1였다. 시간제어의 경우 일정간격으로 일정한 수량을 분무하기 때문에 분무입자가 모두 증발하지 못하고 온실 내부에 누적되어 온실 내부의 상대습도를 증가시켜 냉방효율을 감소 시키는 원인이 되고 차광망이 온실내부의 공기흐름을 차단하여 증발효율을 감소시키는 것으로 나타났다. 포그냉방시스템의 냉방효율을 높이기 위해서는 온실 내부의 상대습도에 의한 제어방식과 내부 공기의 순환에 대한 연구가 필요하다.
오하이오 중부에서 풍속이 0.5m.s-1인 경우는 매우 드물었으며, 5년 평균 풍속은 약 2.5 m.s-1인 것으로 나타났다. 최고 기온이 35t인 오하이오주의 대표적인 여름에 온실 내의 여섯 곳에서 측정된 기온의 최대범위는 1.7℃, 온실 내외 기온의 최대차는 3.5℃인 것으로 나타났다. CFD 모델에서의 온도 분포를 분석한 결과, 온실의 환기 회수가 0.9 회/분 이상일 때 실내 공기가 외부 기온을 2.8℃이상 초과하는 경우는 없었던 것으로 예측되었다. 풍향과 풍속에 따라서 각각의 환기구들의 효율성이 영향을 받는 것으로 나타났으며, 특히 환기창을 통해 유입되는 강한 바람에 의하여 발생하는 공기의 소용돌이들은 지붕창들의 효율성에 많은 영향을 미치는 것으로 예측되었다. CFD model은 서쪽에서와 동쪽에서 불어오는 바람이 각각 2.1 m.s-1와 3.5 m.s-1이상일 때 이 연동형 온실은 적정한 자연 환기량을 취할 수 있다고 예측하였다. 측면창 바로 옆에 위치한 식물군과 벤취에 의해 측면창을 통한 자연적인 공기의 유입이 방해를 받기 때문에, 바람이 서쪽에서 불어올 때 식물군이 없을 때보다 평균 12%의 환기량의 감소 결과를 가져오는 것으로 예측되었다. 식물군은 공기의 유입창의 위치보다 약간 낮은 곳에 위치하여야 하며, 유입창을 너무 높이 설치하면 측면창을 통해 유입되는 공기는 가장 근접한 지붕창을 통해 대부분이 배출되는 것으로 예측되었다. 연동형 자연환기식 온실에 있어서 바람이 불어오는 쪽의 측면창들과 바람의 반대쪽을 향한 지붕창들의 혼합형이 가장 효율적인 온실 설계인 것으로 예측되었다.