        1.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to prepare a plan for the controlling indoor microclimate environment using natural ventilation for the single-span plastic greenhouses, which account for about 83.8% of the total area of horticultural greenhouses in South Korea. The changes of indoor air temperature and relative humidity according to the side opening height were experimentally compared and analyzed in the experimental greenhouse. As the side opening height was changed to 30, 70, and 110cm, the indoor and outdoor temperature differences were found to be 14.0, 10.1, and 7.7℃, respectively. The indoor and outdoor relative humidity differences were found to be -15.7, -12.5, and -11.1%, respectively. These results were verified for statistical significance by ANOVA. When the variable breadth of the outdoor temperature was 6.9℃, the indoor temperature breadths were 14.5, 12.3, and 9.0℃, and when the outdoor relative humidity breadth was 24%, the indoor relative humidity breadths were 31.2, 28.0, and 23.8%, respectively. It was analyzed that as the side opening height is increased, the indoor temperature and relative humidity become similar to the outdoor environment. This is because the air is mixed by active indoor-outdoor air movement of greenhouses with natural ventilation. The results indicated that the proper opening and closing of side openings is necessary for the stable indoor microclimate environment control of plastic greenhouses.
        4,000원
        2.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 권취식 측창을 갖는 아치형 단동 플라스틱 온실 내 강제환기장치 설치 및 운용, 환기 성능 개선방안 등을 제안 하기 위해 온실 내부에 유동팬과 배기팬을 설치하여 강제환기 장치 사용에 따른 온실 내부기온 강하 특성을 정량적으로 조 사하였다. 시험은 3가지 환기 조건(측창, 측창+순환팬, 측창+ 순환팬+배기팬)에서 수행되었다. 각 조건 데이터로거를 이용 하여 환기 시작과 동시에 온실 내외부 기온 및 외부환경 변화 를 측정·기록하였고, 환기 방식별 기온차 변화의 평균값으로 부터 정규기온차를 계산하여 기온 강하 효과를 비교하였다. 오전(11:00-12:00)에는 환기 방식에 상관없이 환기 초반 정 규기온차가 일시적으로 증가했다가 감소하는 것으로 나타났 다. 강제환기장치가 더 많이 사용될수록 최대 정규기온차는 1.158에서 1.037로 감소하였고 최대 정규기온차에 도달하는 시간도 340초에서 110초로 단축되었다. 강제환기장치의 사 용은 정규기온차가 0.8까지 감소하는데 소요된 시간을 1,030 초에서 550초로, 0.6까지는 1,610초에서 915초로, 0.4까지는 2,315초에서 1,360초로, 자연환기의 약 60% 수준으로 감소 시켰다. 오후(14:00-15:00)에는 정규기온차의 증가가 관측되지 않았지만, 환기 시작과 동시에 기온차가 감소하기 시작 했다. 또한 강제환기장치가 더 많이 사용될수록 정규기온차 가 0.8까지 내려가는 시간을 560초에서 345초로, 0.6까지는 825초에서 540초로, 0.4까지는 560초에서 345초로, 약 70% 수준으로 감소시켰다. 따라서, 보다 효과적이고 경제적인 환 기를 위해 강제환기장치는 오전과 같이 열부하가 높은 환경에 서 적극적으로 사용하는 것이 바람직하다고 판단된다.
        4,000원
        3.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to investigate the effect of side vent heights on temperature and relative humidity inside and outside the single-span plastic greenhouse (W: 7 m, L: 40 m H: 3.9 m) during natural ventilation. Four different heights (120, 100, 80, 60 cm) of the side vent were used as an experimental condition. Variations of temperature and relative humidity inside and outside the greenhouse and the differences between heights were compared by using one-way ANOVA. In the daytime, the difference in temperature between inside and outside the greenhouse was dropped from 14.0°C to 7.1°C as the side vent height increased. The temperature difference in the nighttime was less than 0.2°C regardless of the height. One-way ANOVA on the temperature difference between heights presented that the statistical significance was founded between all of the combinations of height in the daytime. The difference in relative humidity between inside and outside the greenhouse was grown from –13.8% to – 22.2% with a decrease in the side vent height. The humidity difference in the nighttime was less than 1% regardless of the height. One-way ANOVA on the humidity difference revealed that most of the side vent heights showed significance in the daytime but between 100 and 80 cm was not significant. It seemed because the external air became cooler during the experiment with a height of 80 cm. Conclusively, this study empirically demonstrated that the higher side vents resulted in the decrease of differences in temperature and relative humidity between inside and outside the greenhouse, and also the effect of side vent height was statistically significant. This study may be helpful for deciding the height of the side vent effective for controlling temperature and relative humidity in a single-span greenhouse during natural ventilation.
        4,000원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an accelerated weathering test was performed to examine the variation of thermal insulation performance according to the service life. A widely used class 1 thermal screen (matt georgette + polyethylene (PE) foam + chemical cotton + felt + matt georgette) was selected as the target thermal screen. The ultraviolet irradiation that reached the target thermal screen specimen (60 x 60cm) was 5mW/cm2. Thus, the ultraviolet irradiance was set to 5mW/cm2, and the exposure periods of accelerated weathering conditions on the specimens were set to 0, 282, 847, and 1412h. The radiation exposure periods of the weathering conditions for 0, 282, 847, and 1412h indicate the amount of ultraviolet accumulation for 0, 1, 3, and 5years, respectively. In the accelerated weathering test, the target specimens that completed each exposure phase were subjected to the hotbox test to analyze their thermal insulation performances. Consequently, the thermal insulation performance of the multi-layer thermal screen was estimated to degrade rapidly after approximately two years. In the accelerated weathering condition, a quadratic function model was used to calculate the expected service life, since it adequately described the variation in thermal insulation of the thermal screen according to time. The results showed that when the thermal insulation performance degraded by 5, 10, 20, and 30%, the expected service lives were 2.5, 3.3, 4.5, and 5.5years, respectively.
        4,000원
        5.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The efficient nutrient solution cooling system consisting of buffer tank, three-way valve, and heat pump et al. was developed for hydroponics of leafy vegetables at high temperatures period. It was designed in such a way that the buffer tank was first cooled to enable precise temperature control of the nutrient solution with small capacity heat pump. Developed system was installed in the NFT hydroponics farm cultivating leafy vegetables and performance evaluation was carried out. For cultivation of Lalique lettuce(Lactuca sativa var.), the temperature of nutrient solution tank, buffer tank, and the root zone, the performance of cooling system, and the environment of greenhouse were analyzed. Also, by measuring the growth and yield of lettuce, the effect of cooling nutrient solution on the growth of lettuce NFT hydroponics was analyzed.
        4,000원
        6.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 최근 신소재 단열재로 주목받고 있는 실리카 에어로겔을 이용하여 현재 사용되고 있는 다겹보온커튼의 단점을 보완하고 보온성을 유지 및 향상시킬 수 있는 새로운 조합의 다겹보온커튼을 제작 하여 현장에 설치함으로써 보온성과 경제성을 분석하고자 한다. 실험에 사용된 다겹보온커튼은 실리카 에어로겔이 함유된 부직포를 사용하여 2가지의 조합으로 제작하였으며 시중에 판매, 사용되고 있는 관행 다겹보온 커튼과의 차이에 따른 온습도변화와 연료소비량을 측정하여 비교분석하였다. 실험결과 단동온실과 연동온실에서 다겹보온커튼 차이에 따른 온습도변화는 미세하게 나타났으나, 거의 비슷한 온습도 값을 유지하였다. 이는 실리카 에어로겔을 이용한 다겹보 온커튼이 관행 다겹보온커튼에 비해 온습도 제어 측면에서 문제가 없음을 나타냈다. 난방에너지 비교분석 결과, 실리카 에어로겔을 이용한 다겹보온커튼이 관행 다겹보온커튼에 비해 연료소비량은 단동온실에서 약 15%, 연동온실에서 약 20% 의 연료소비량을 절감한 것으로 나타나 온실의 규모와 사용기 간이 증가함에 따라 난방에너지는 절감될 것으로 판단된다. 실리카 에어로겔 이용 다겹보온커튼이 관행 다겹보온커튼에 비해 통기성과 보온성이 증가되는 것이 확인되었다. 그러나, 연동온실에서 사용된 다겹보온커튼은 관행 다겹보온커튼에 비해 무게가 증가하고 뻣뻣하여 시공성과 작동성이 떨어지는 것을 확인할 수 있었다. 이에 단동온실에서 사용된 다겹보온 커튼에서는 개선사항을 적용하였다. 내부단열재의 교체를 통해 두께를 감소시키고 뻣뻣함을 개선함으로써 농가가 사용하 기에 충분한 가능성이 있다는 것을 확인하였다.
        4,000원
        7.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 일정한 풍환경하에 온실 피복재 관류전열손실을 분석하기 위하여 온실 열손실 분석용 소형 풍동을 제작하고 그 성능을 분석하였으며 모형온실을 적용하였을 때의 관류전열손실을 분석하였다. 소형 풍동은 시험부 측 공기흐름이 정상상태를 유지하고 편차를 최소화하기 위하여 풍동의 각 요소를 반영하여 구성하였으며 송풍부, 확산부, 정류부, 축소부, 시험부로 구성하였다. 소형 풍동의 형태는 개방형, 토출식으로 결정하였고, 시험부 규격은 제작하고자 하는 모형온실의 규격과 상사비율, 시험부의 단면 폐쇄율을 감안하여 결정하였다. 상사비율을 풍동실험에 적용할 모형은 농업시설 중 가장 큰 비중을 차지하고 있는 단동 비닐온실을 대상으로 하였다. 소형풍동 내 풍속을 조절함에 따라 나타나는 모형온실 피복재의 관류전열계수는 피복재 면을 크게 지붕면과 측벽면, 앞뒷면으로 나누고 각 면별 계측 데이터를 평균 내어 산출하였다. 지붕면은 풍속이 증가함에 따라 전열계수도 증가하나 증가폭이 감소하는 구간은 배치각도에 따라 1-2ms-1과 2-3ms-1으로 구분되어지는 것으로 판단되었다. 측벽면의 전열계수가 증가하는 폭이 큰 구간은 0-1ms-1 구간인 것으로 판단된다.
        4,000원
        9.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to analyze the distribution characteristics of mist spray particle size by devising a rotary mist spraying device to develop the evaporative salt water desalination system. The rotary mist spraying device was consisted of a BLDC sirocco fan, a spinning fan, a fan fixed shaft and a salt water supply device etc. In this study we analyzed the characteristics of spray particle size and distribution according to the variation of sirocco fan surface roughness(Ra, μm), revolutions(rpm) and salt water flow rate(mL/min). When sirocco fan surface roughness( Ra) was in the range of 0.27~7.65 μm, the spray particle size was 0.117~1.360 μm. And then more than 90% of spray particles were found to be less than 0.50 μm. When sirocco fan surface roughness(Ra) was in the range of 12.70~22.84 μm, the spray particle size was 2.51~184.79 μm and more than 98% of spray particles were found to be less than 13.59 μm. To analyze the effect of fan rotation speed on the size and distribution of spray particles, when surface roughness Ra was fixed 0.27 μm and fan rotation speed and salt water flow rate was respectively changed at 3,800~5,600 rpm and 2.77~8.28 mL/min, spray particle size was 0.341~0.541 μm. And when salt water flow rate was 9.74 mL/min and fan rotation speed was 3,800~5,200 rpm, spray particle size was in the range of 29.29~341.46 μm and in case of 5,600 rpm more than 98.23% of spray particles were in the range of 2.51~13.59 μm.
        4,000원
        10.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관 (백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 20~23oC, 관부 온도를 13~15oC로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 20~23oC의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함 으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 4oC + 관부난방(처 리 1), 공간 난방 8oC (대조구), 공간 난방 6oC + 관부 난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 8oC(대조구)의 경우 1,320L (100%), 공간난방 4oC + 관부난방의 경우 928L(70.3%), 공간난방 6oC + 관부난방의 경우 1,161L (88%)로 계측 되었다. 공간난방 4oC + 관부난방(처리 1) 및 공간난방 6oC + 관부난방(처리 2)은 8oC 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.
        4,000원
        11.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.
        4,000원
        12.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The multi-layer insulating curtains used in the experiment was produced in six combinations using non-woven fabric containing aerogel and compared and analyzed by measuring heat flux and heat perfusion rates due to weight, thickness and temperature changes. Using silica aerogel, which have recently been noted as new material insulation, this study tries to produce a new combination of multi-layer insulating curtains that can complement the shortcomings of the multi-layer insulating curtains currently in use and maintain and improve its warmth, and analyze the thermal properties. The heat flux means the amount of heat passing per unit time per unit area, and the higher the value, the more heat passing through the multi-layer insulating curtain, and it can be judged that the heat retention is low. The weight and thickness of multi-layer insulation curtains were found to be highly correlated with thermal insulation. In particular, insulation curtains combined with aerogel meltblown non-woven fabric had relatively higher thermal insulation than insulation curtains with the same number of insulation materials. However, the aerogel meltblown non-woven fabric is weak in light resistance and durability, and there is a problem that the production process and aerogel are scattering. In order to solve this problems, the combination of expanded aerogel non-woven fabric and hollow fiber non-woven fabric, which are relatively simple manufacturing processes and excellent warmth, are suitable for use in real farms.
        4,000원
        13.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature 60℃, the heat flux of multi-later insulating curtain is T Co.(73.1W/m2) > S Co.(119.5W/m2) > U Co.(155W/m2) > N Co.(163.1 W/m2) > P Co.(177.7W/m2). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.
        4,000원
        14.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 방울토마토 재배 단동온실에 공기순환팬을 설치하고 공기순환팬이 온실 내 온도 및 습도 분포, 에너지소비량에 미치는 영향을 분석하였다. 공기순환팬은 날개 크기 230mm의 Stainless 팬으로, Lee 등(2016)의 연구결과를 참고하여 시험구 온실에 9m 간격으로 총 18 대를 설치하였다. 온실 내부 온습도는 온실 길이방향으 로 4등분하여 1/4 지점과 3/4 지점의 중앙에 센서를 설치하고 0.8m, 1.8m 높이 2곳의 온습도를 난방을 주로 하는 야간(오후 6시~다음 날 오전 7시)에 5분 간격으로 측정하였다. 에너지소비량은 각 온실에 위치한 온수펌프의 유량, 온수 출수부와 환수부의 온도차를 측정하여 계산하였다. 공기순환팬을 사용하지 않았을 때 측점 간 온도차 및 습도차의 평균값은 0.75oC, 2.19%였으며 공기 순환팬 사용 시 측점 간 온도차 및 습도차의 평균값은 0.42oC, 1.27%로 감소하였다. 공기순환팬 설치 온실과 미설치 온실의 누적 에너지소비량은 각각 4,673kWh, 4,009kWh로 공기순환팬 설치 온실에서 약 14.2%의 에너지를 적게 소모하였다. 이러한 결과로 보아 온실 내 공기순환팬 사용은 공기를 지속적으로 교반시켜 주어 온실 전체의 온도 및 습도를 균일하게 만들고, 공기의 온도가 빠르게 변하지 않도록 해주어 난방 장치의 가동 시간과 에너지소비량을 줄일 수 있다.
        4,000원
        15.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        단동 이중비닐하우스에서 수막에 의한 열전달 특성 및 가온효과를 구명하기 위하여 작물이 재배되는 수막온실의 실내외 기온과 수막의 수온 등을 계측하였고, 단위 피복면적당 수막에 의한 총 공급열량, 열관류율, 관류열량, 온실 내부로 전달되는 열량비율 변화를 비교·분석하였다. 1중과 2중사이의 기온은 외부기온보다는 수막유량과 공급수온에 따라 결정되는 것으로 나타났다. 수막유량이 증가할수록, 공급수온이 높을수록 수막과 2중 하우스 내부와의 열관류율(UW-IN)은 유의하게 증가하는 경향을 보였다. 그러나 수막유량과 공급수온이 일정조건(수 막유량 0.00266L·m-2·s-1, 공급수온 19.8oC) 이상에서는 UW-IN 값이 10W·m-2·oC-1 정도로 수렴되는 것으로 나타났다. 수막과 1·2중 공기 사이의 열관류율(UW-B)의 경우에도 수막유량 및 공급수온에 따라 증가하는 경향을 보였으나, 경향성은 상대적으로 작은 것으로 분석되었다. UW-B는 연구자에 따라 전체적으로 큰 차이를 보이고 있으며, 본 연구에서는 3.27~4.44W·m-2·oC-1의 범위를 보였다. 수막에 의한 총 공급열량(QW)과 온실 내외부로 전달 되는 관류열량(QW-IN, QW-B)의 경우, QW 값이 QW-IN과 QW-B의 합과 매우 유사하게 일치하고 있어 본 연구에서 제시한 결과가 신뢰성이 있음을 확인할 수 있었다. 수막에 의해 내부공기를 가열하는데 사용되는 열량은 최대 57% 수준으로 분석되었고, 우리나라 수막재배온실의 경우 약 22~28% 수준으로 판단된다. 본 연구는 농업인이 실제 사용하는 수막온실과 가장 유사한 조건에서 수막에 의한 온도변화, 열관류율과 관류열량을 계량화함으로써 향후 경제적인 수막온실 설계 시 활용할 수 있을 것으로 기대된다.
        4,000원
        16.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 유리온실 경영비 절감을 위한 고효율 난방기술을 개발하기 위하여 지하수열원 히트펌프, 알루미늄 다겹보온커튼, 근권부 국소난방장치를 조합한 난방 패키지 모델을 구성하고 파프리카 재배 벤로형 유리온실에 적용 시험을 수행하였다. 적용효과 분석을 위하여 관행 경유온수보일러와 일반 보온커튼을 설치한 대조구 온실과 비교시험을 통해 온실환경, 난방비용, 작물생육 등을 검토하였다. 알루미늄 다겹보온커튼과 일반 부직포 보온커튼을 설치한 온실에 대한 무가온 조건에서의 야간 온도 비교시험에서 알루미늄 다겹보온커튼 설치 온실의 온도가 일반 부직포 보온커튼 설치 온실에 비해 평균 2.2oC 더 높게 유지됨을 확인하였다. 또한 근권부 국소 난방장치를 설치한 온실에서 미설치 온실에 비해 야간 난방 중의 베드내부 근권온도가 4.7oC 더 높게 유지됨을 확인하였다. 난방패키지를 구성하는 지하수열원 히트펌프의 난방성능을 분석한 결과 지하수를 직접 열원으로 이용하는 시스템 특성상 난방성능계수는 평균 3.7로 비 교적 높게 나타났다. 난방패키지를 적용한 처리구 온실과 관행 난방의 대조구 온실에 대하여 연료소비량을 계 측한 결과 10a(1,000m2)당 대조구 온실은 경유 14,071L, 전력 364kWh를 소비하였고, 처리구는 전력 35,082kWh 를 소비하여 난방비용 기준으로 대조구 온실의 비용 절감율은 87%로 나타났다. 처리구 및 대조구 온실의 작물 생육을 비교한 결과 초장과 엽록소 함량에서 차이가 발생하였으나 두 온실의 난방온도가 거의 동일하므로 전체적인 생육은 큰 차이가 없는 것으로 분석되었다. 원예시설의 난방에너지 절감효과를 극대화하기 위해서는 본 연구의 난방패키지를 구성하는 개별 기술뿐 아니라 이미 개발된 고효율 공조기 이용기술, 보온성 향상기술, 온도 관리 기술 등을 지역, 시설, 작목, 작형 등에 최적화하여 조합할 수 있는 추가적 패키지 모델의 개발 연구가 필요한 것으로 판단되었다.
        4,000원
        17.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        순환식 수막시스템의 적정 수온을 결정하는데 필요한 기초자료를 제공하기 위하여 딸기를 토경재배하고 있는 실험온실에서 외부온도, 수막용수의 수온 및 야간시간대에 따른 처리방식별 온실 내부 환경변화를 비교 분석하였다. 대조구는 무수막 온실이고, 처리구는 수온이 10oC, 15oC로 각각 설정된 순환식 수막온실로서 모두 무가온 및 추가적인 보온자재의 투입이 없는 상태를 말한다. 수막이 직접 살수되는 2중 비닐하우스는 폭 5.5m, 길이 55m이고, 분당 살수되는 평균 수막유량은 38.5~44.5L로 나타났다. 3가지 처리조건 모두에서 외부온도와 내부온도는 양의 선형관련성이 매우 높게 나타났으며 처리구 (10, 15oC)의 외부온도에 대한 상관성은 유사한 수준으로 분석되었다. 보온효과는 수온 15oC 처리구가 수온 10oC 처리구보다 1.3oC 정도 우수한 것으로 나타났다. 외부온도가 약 -8.1~8.6oC 범위에서 변화할 때, 처리조건 별 최저온도는 무처리구, 수온 10oC 처리구, 수온 15oC 처리구가 외부에 비해 각각 6.4, 11.0, 12.3oC 정도 높게 유지되는 것으로 나타났다. 평균 온도는 무처리구, 수온 10oC 처리구, 수온 15oC 처리구의 순으로 높아지고 온도변화폭은 오히려 작아지는 경향을 보였다. 외부 최저 온도가 -1.3oC, 평균온도가 1.5oC인 날은 수막시스템의 수온을 10oC로, 외부 최저온도가 -4.7oC, 평균온도가 -0.2oC 인 날은 수온을 15oC로 설정해도 온실의 목표온도(5oC) 유지가 가능한 것으로 나타났다. 처리조건별 야간시간대( 일몰 후, 자정, 일출 전, 일출 후)에 따른 온실 내부와 외부의 온도는 전반적으로 일몰직후가 가장 높고, 이후 서서히 감소하여 일출직전이 가장 낮아지는 경향을 보였다. 따라서 온실의 목표온도 유지를 위해서는 일출직전 시간대에 특히 집중적인 관리가 필요하며, 순환식 수막 시스템의 수온을 획일적으로 15oC 이상으로 결정하기 보다는 외부온도 변화, 야간시간대, 재배작물에 따라 다르게 결정하는 것이 타당한 것으로 판단된다.
        4,000원
        18.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The area of greenhouse heating is 21,202 ha which becomes 42% among the total greenhouse area. As heating fuel, diesel or oil is usually used by 60%, and the heating cost takes 30 to 40% percentage at the greenhouse running. In this study, the pellet fuel heater was developed to replace oil for reducing the burden of greenhouse heating cost. The pellet fuel heater was composed of a conveying grate stoker, which could control temperature precisely like the diesel heater. Diesel and pellet were used for the greenhouse heating, whose calorific values are 9,200 and 3,898 kcal/kg, respectively. As the heating cost due to the saving effect of pellet fuel heater compared with diesel, greenhouse heating cost was reduced by 44% with pellet
        4,000원
        19.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Importance of alternative energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to 40 % of the total production cost in Korean protected cultivation needs to be reduced for profitability and global competition. Therefore, this study was conducted to develop energy model and regional resource for recycling of resource in greenhouse. Based on the results of the theoretical and statistical investigations, energy model of regional resource was developed. This results was shown with a new standard 2,000 heads of pigs. Livestock manure was originated 8.6 kg/day/one head, and the average biogas yield was 1.23 Nm3/day occurred. The biogas reactor and engine showed that scale of 300 m3 was 25kW respectively. Agricultural and Forest Residual-products Biomass quantity in heating road of 200,000kcal/h were 1,224 kg, 912 kg respectively.
        4,000원
        20.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 온실의 관류전열량을 분석하고 예측하는데 필요한 기초자료 제공을 위하여, 공기막 이중 PO필름의 열저항식을 모델링하였고, 전도, 복사, 대류에 의한 열저항 특성을 규명하였다. 또한 열저항식의 타당성 검증을 위해 열저항식에 의한 관류전열량의 계산값과 실험값을 비교·분석하였다. 공기막 이중 PO필름의 열저항식은 PO필름, 공기막, PO필름의 직렬 열저항식으로 구성되며, 공기막은 복사와 대류에 의한 병렬 열저항식으로 구성된다. 고온부 T1의 평균온도는 276.1K, 저온부 T2의 평균온도는 266.8K로 나타났으며, 다른 조건들이 동일할 경우 챔버 내부온도가 높을수록 T1과 T2의 평균온도와 온도차가 증가하는 것을 확인할 수 있었다. 전도열저항은 0.00091K ·W−1로 전체 열저항의 1% 미만으로 매우 미미한 수준이고, 공기막의 열저항이 0.18K ·W−1로 전체 열저항의 99% 이상을 차지하는 것으로 나타났다. 공기막의 경우 대류열 저항이 복사열저항에 비해 1.33~2.08배 정도 크게 나타났으며, 복사열저항은 평균온도의 3제곱에 반비례하고 대류열저항은 온도차가 4.7, 5.3, 5.5, 5.7, 12.3, 13.2, 13.3, 13.5, 13.8 및 14.0K로 증가할 때 각각 0.78, 0.75, 0.74, 0.73, 0.57, 0.56, 0.56, 0.56, 0.55 및 0.55K ·W−1 로 감소하였다. 관류전열량의 계산값과 실험값의 차이는 실험조건별로 0.6~17.2W의 범위로 평균 6.9W였으며, 실험값은 계산값의 79.8~97.7% 범위로 평균 87.3% 수준으로 나타났다. 전체적인 계산값과 실험값의 관류전열량 경향성은 잘 일치하고 있으며, 공기막 이중필름의 열 저항은 공기막 두께 및 주입공기의 종류와는 직접적인 상관관계를 보이지 않았다.
        4,000원