        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effect of crown heating on the cultivation environment, budding, flowering and yields of strawberry was analyzed. In December, January, and February, when the outside temperature was low, the average strawberry crown temperature at daytime in the test zone was 1.3°C higher than that in the control zone, and the average strawberry crown temperature at nighttime in the test zone was 2.7°C higher than that in the control zone. The average bed temperature at daytime in test zone was 1.7°C higher than that in the control zone, and the average bed temperature at nighttime in test zone was 2.4°C higher than that in the control zone. As a result of performing correlation analysis and regression analysis on strawberry crown temperature and budding period, the correlation coefficient was -0.86, which tended to be shorter as the crown temperature was higher, and the determination coefficient was 0.74. The total yields of strawberry during test period were 392.6 g/plant for test greenhouse and 346.0 g/plant for control greenhouse respectively. As for the quality of strawberries, the ratio of 2L (very large) grades and L (large) grades was 62.4% in the test greenhouse and 58.5% in the control greenhouse, indicating that the proportion of high quality strawberries was higher in the test greenhouse.
        4,000원
        2.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 ‘설향’ 딸기를 두 작기(2020-2021년, 2021 -2022년)에 걸쳐 재배하면서 외부 광환경과 생육도일온도 가 작물 생산량에 미치는 영향을 분석하였다. 2년 동안 온실 내 환경 관리, 양액 관리 등은 동일하게 하였다. 재배기간 중 주 간의 온실 온습도는 두 작기에서 유사하게 관리되었고, 야간 의 온습도는 통계적으로 차이가 있었으나 작물 생육 범위를 벗어나지 않았다. 일사량은 9월과 10월에 첫 번째 작기의 일 평균 일사량이 많아 누적일사량도 많았으며, 11월부터는 2월 까지는 두 번째 작기의 일사량, 3월에는 다시 첫 번째 작기의 일사량이 많은 것으로 나타나 1월부터의 누적일사량은 두 번 째 작기에서 많은 것으로 나타났다. 딸기의 최적 일장 조건인 8시간 이상의 일장이 나타난 일은 두 작기 간 큰 차이가 없었고, 변화 양상은 누적일사량의 변화와 유사하게 나타났다. 누 적일사량과 생육도일온도는 상관관계가 커 생육도일온도가 딸기의 생산량과 당도에 미치는 영향을 조사해 본 결과의 초 기의 누적일사량과 생육도일온도가 적었던 두 번째 작기에서 초기 수확량은 적었으나 누적일사량 및 생육도일온도가 증가 함에 따라 후기에 수확량이 첫 번째 작기보다 많았으며 잠재 적 최대 생산량도 큰 것으로 나타났다. 당도는 생육도일온도 가 증가함에 따라 감소하였으며, 이는 촉성딸기의 특성으로 판단된다. 추후 연구를 통해 단순 수확량뿐만 아니라 작물 생 육, 꽃눈분화 및 출뢰시기를 조사, 분석하여 생육도일온도가 작 물 생육에 미치는 영향을 다각도로 분석하는 연구도 필요하다 고 판단된다.
        4,000원
        3.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하절기 토마토 재배 시 주간 포그 냉방, 야간 히트펌프 냉방을 처리를 하여 냉방 처리가 온실 내 온습도, 작물의 생육 및 수확량에 미치는 영향을 분석하였다. 하절기 주간에 차광 처리한 대조구 온실의 평균 온습도는 32.1°C, 59.4%였고, 포그 처리한 시험구 온실의 평균 온도는 30.0°C, 74.3%로 나타났다. 이 때 외부의 평균 온습도는 31.4°C, 57.7%로 대조구 온실의 온도는 외기보다 0.7°C 높았으나 시험구 온실의 온도는 외기보다 1.4°C, 대조구보다 2.1°C 낮게 나타났다. 평균 습도는 시험구 온실 74.3%, 대조구 온실 59.4%로 포그 처리를 한 시험구에서 높게 나타났다. 야간 대조구 온실의 평균 온습도는 25.2°C, 85.1%였고, 히트펌프로 냉방을 한 시험구 온실의 평균 온습도는 23.4°C, 82.4%, 로 나타났다. 야간 외부의 평균 온습도는 24.4°C, 88.2%로 대조구 온실의 온도는 외기보다 0.8°C 높았으나 시험구 온실의 온도는 외기보다 1.0°C, 대조구보다 1.8°C 낮게 나타났다. 평균 습도는 시험구 온실 82.4%, 대조구 온실 85.1%로 나타나 시험구 온실의 습도가 더 낮게 나타났다. 작물 생육은 정식하고 8주 후에는 두 온실 간의 큰 차이는 없는 것으로 나타났으나 냉방 처리 후에는 시험구 온실의 작물이 대조구에 비해 경경, 초장, SPAD 값이 높게 나타났다. 토마토의 수확량은 냉방을 시작하고 2주 후까지 총 생산량의 차이는 1.2%로 큰 차이 없었으나 3주 후와 4주 후의 일 생산량이 시험구에서 대조구보다 많게 나타났다. 최종적으로는 시험구의 수확량이 81.3kg, 대조구의 수확량이 73.8kg으로 시험구가 대조구에 비해 10.2% 많게 나타남으로써 하절기 주간 포그 냉방, 야간 히트펌프 냉방이 작물 성장에 적합한 환경을 조성해 줌으로써 생육 및 생산성에 영향을 미친 것으로 판단된다. 냉방 처리에 따른 경제성을 비교해보면 대조구 온실에서는 142,166원의 수익이 있었던 반면 시험구 온실에서는 28,727원의 손해가 발생하여 냉방 처리는 경제성이 떨어지는 것으로 나타났다. 그러나 재식 밀도, 히트펌프 운용 시간 및 기간을 조절하여 에너지 사용은 줄이면서 생산성을 증가시킨다면 경제성도 확보할 수 있을 것으로 기대되며 이에 대한 추가 연구가 필요할 것으로 판단 된다.
        4,000원
        4.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 ‘설향’ 딸기의 관부를 부분 난방하고 양액을 온수로 공급하면서 관행 재배 방식에 비해 온실 공간 온도를 낮게 관리하는 딸기 부분 난방 시험을 수행하였다. 정식 후 11월까지는 특별한 처리가 없어 대조구, 시험구 모두 온실 내 환 경이 유사하게 관리되었으며 관부 난방 및 온수 양액을 공급 하기 시작한 12월부터는 야간의 온실 온도, 관부 온도 및 베드 온도가 차이를 보였다. 12월의 온실 야간 평균 온습도는 대조구 7.1℃, 87.2%, 시험구 5.7℃, 88.7%로 시험구의 온도가 낮았으나 관부 난방을 수행함으로써 시험구 온실의 관부 및 베드의 온도를 9.3℃, 12.7℃로 유지하였고, 대조구 온실의 관부 및 베드 온도 7.9℃, 10.8℃보다 높게 관리할 수 있었다. 시험기간 내에서 시험구 온실의 딸기 관부 및 베드 온도는 대조구에 비해 모두 약 2.0℃ 가량 높게 유지되는 것으로 나타났다. 주간에는 온수 양액을 공급함으로써 지하수를 이용했을 때보 다 평균 8.7℃ 높은 온도 양액을 공급할 수 있었고 이로 인해 베드 온도도 약 5.0℃ 가량 높게 나타났다. 시험구에서는 시험 기간 동안 온실 난방, 관부 난방 및 온수 양액 공급에 총 9,475.7×10 3 kcal의 에너지를 소비하였고 대조구에서는 온실 공간 난방에 총 16,847×10 3 kcal의 에너지를 소비하여 시험구에서 대조구 대비 약 43.8%의 에너지 절감 효과를 확인할 수 있었다. 시험구에서 딸기 관부의 온도를 높게 관리함으로써 작물의 생육을 촉진시킬 수 있었고 그로 인해 정식 후 초세가 대조구에 비해 좋지 않았던 시험구의 딸기가 25주 후에는 대조구와 생육적인 면에서 큰 차이가 없는 것으로 나타났다. 딸기의 수확량은 초세가 좋았던 대조구에서 1화방의 수확량이 시험구에 비해 많았으나 2화방, 3화방에서는 관부의 온도를 높게 관리한 시험구의 수확량이 더 많았다. 3월 말까지의 주당 수확량은 시험구 412.7g/plant, 대조구 393.3g/plant로 유의미한 차이는 없었으나 시험구가 대조구에 비해 4.9% 많이 나온 것으로 보아 딸기의 온도 민감부인 관부의 온도를 높게 관리하는 것이 딸기 생육과 생산성에 영향을 미치는 것으로 판단된다.
        4,000원
        5.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 최근 신소재 단열재로 주목받고 있는 실리카 에어로겔을 이용하여 현재 사용되고 있는 다겹보온커튼의 단점을 보완하고 보온성을 유지 및 향상시킬 수 있는 새로운 조합의 다겹보온커튼을 제작 하여 현장에 설치함으로써 보온성과 경제성을 분석하고자 한다. 실험에 사용된 다겹보온커튼은 실리카 에어로겔이 함유된 부직포를 사용하여 2가지의 조합으로 제작하였으며 시중에 판매, 사용되고 있는 관행 다겹보온 커튼과의 차이에 따른 온습도변화와 연료소비량을 측정하여 비교분석하였다. 실험결과 단동온실과 연동온실에서 다겹보온커튼 차이에 따른 온습도변화는 미세하게 나타났으나, 거의 비슷한 온습도 값을 유지하였다. 이는 실리카 에어로겔을 이용한 다겹보 온커튼이 관행 다겹보온커튼에 비해 온습도 제어 측면에서 문제가 없음을 나타냈다. 난방에너지 비교분석 결과, 실리카 에어로겔을 이용한 다겹보온커튼이 관행 다겹보온커튼에 비해 연료소비량은 단동온실에서 약 15%, 연동온실에서 약 20% 의 연료소비량을 절감한 것으로 나타나 온실의 규모와 사용기 간이 증가함에 따라 난방에너지는 절감될 것으로 판단된다. 실리카 에어로겔 이용 다겹보온커튼이 관행 다겹보온커튼에 비해 통기성과 보온성이 증가되는 것이 확인되었다. 그러나, 연동온실에서 사용된 다겹보온커튼은 관행 다겹보온커튼에 비해 무게가 증가하고 뻣뻣하여 시공성과 작동성이 떨어지는 것을 확인할 수 있었다. 이에 단동온실에서 사용된 다겹보온 커튼에서는 개선사항을 적용하였다. 내부단열재의 교체를 통해 두께를 감소시키고 뻣뻣함을 개선함으로써 농가가 사용하 기에 충분한 가능성이 있다는 것을 확인하였다.
        4,000원
        6.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the humidity control effect of a counter-flow ventilator was analyzed in a greenhouse with high relative humidity at night in the winter season. A case of the counter-flow ventilator was 0.96 × 0.65× 0.82(W× D × H, m) and there were heat transfer element and two fans for air supply and exhaust in the counter-flow ventilator. Two counter-flow ventilators were used in this study and the setting humidity of the ventilators was 80%. The temperature and relative humidity at night(18:00-8:00) in the greenhouse were measured. In a greenhouse without a counter-flow ventilator, the average temperature and humidity was 14.9°C, 82.8%, respectively. When the counter-flow ventilator was operated, the corresponding averages were 15.1°C, 79.9%. The independent sample t test of monthly temperature and relative humidity showed no difference in temperature, and a significant difference in relative humidity with 1% of the significance level. Therefore, using the counter-flow ventilator helps to control relative humidity in greenhouse and increase yield.. And further research considering the pros and cons of using the counter-flow ventilator is needed.
        4,000원
        7.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 일정한 풍환경하에 온실 피복재 관류전열손실을 분석하기 위하여 온실 열손실 분석용 소형 풍동을 제작하고 그 성능을 분석하였으며 모형온실을 적용하였을 때의 관류전열손실을 분석하였다. 소형 풍동은 시험부 측 공기흐름이 정상상태를 유지하고 편차를 최소화하기 위하여 풍동의 각 요소를 반영하여 구성하였으며 송풍부, 확산부, 정류부, 축소부, 시험부로 구성하였다. 소형 풍동의 형태는 개방형, 토출식으로 결정하였고, 시험부 규격은 제작하고자 하는 모형온실의 규격과 상사비율, 시험부의 단면 폐쇄율을 감안하여 결정하였다. 상사비율을 풍동실험에 적용할 모형은 농업시설 중 가장 큰 비중을 차지하고 있는 단동 비닐온실을 대상으로 하였다. 소형풍동 내 풍속을 조절함에 따라 나타나는 모형온실 피복재의 관류전열계수는 피복재 면을 크게 지붕면과 측벽면, 앞뒷면으로 나누고 각 면별 계측 데이터를 평균 내어 산출하였다. 지붕면은 풍속이 증가함에 따라 전열계수도 증가하나 증가폭이 감소하는 구간은 배치각도에 따라 1-2ms-1과 2-3ms-1으로 구분되어지는 것으로 판단되었다. 측벽면의 전열계수가 증가하는 폭이 큰 구간은 0-1ms-1 구간인 것으로 판단된다.
        4,000원
        9.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The most important role of air defense system is to attack the air target of enemy to defend the important military unit or facilities. In order to attack the target as soon as it is detected, fast and precise fire signal transfer using the fire control stick is very important. However, it was found that firing is not conducted in the test for fire control stick. In order to find the reason of such problem and improve life cycle of fire control stick, the test was conducted and it was found that chattering occurred and this led to malfunction of signal transfer from control stick to fire control unit of air defense system. In order to draw resolution for this problem, two contact plate made of beryllium copper is suggested to add to the control stick to enhance the contact and reduce chattering effect. The four fire switch prototypes were tested for 100,000 times and it showed its reliability of use.
        4,000원
        10.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to analyze the distribution characteristics of mist spray particle size by devising a rotary mist spraying device to develop the evaporative salt water desalination system. The rotary mist spraying device was consisted of a BLDC sirocco fan, a spinning fan, a fan fixed shaft and a salt water supply device etc. In this study we analyzed the characteristics of spray particle size and distribution according to the variation of sirocco fan surface roughness(Ra, μm), revolutions(rpm) and salt water flow rate(mL/min). When sirocco fan surface roughness( Ra) was in the range of 0.27~7.65 μm, the spray particle size was 0.117~1.360 μm. And then more than 90% of spray particles were found to be less than 0.50 μm. When sirocco fan surface roughness(Ra) was in the range of 12.70~22.84 μm, the spray particle size was 2.51~184.79 μm and more than 98% of spray particles were found to be less than 13.59 μm. To analyze the effect of fan rotation speed on the size and distribution of spray particles, when surface roughness Ra was fixed 0.27 μm and fan rotation speed and salt water flow rate was respectively changed at 3,800~5,600 rpm and 2.77~8.28 mL/min, spray particle size was 0.341~0.541 μm. And when salt water flow rate was 9.74 mL/min and fan rotation speed was 3,800~5,200 rpm, spray particle size was in the range of 29.29~341.46 μm and in case of 5,600 rpm more than 98.23% of spray particles were in the range of 2.51~13.59 μm.
        4,000원
        11.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.
        4,000원
        12.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The multi-layer insulating curtains used in the experiment was produced in six combinations using non-woven fabric containing aerogel and compared and analyzed by measuring heat flux and heat perfusion rates due to weight, thickness and temperature changes. Using silica aerogel, which have recently been noted as new material insulation, this study tries to produce a new combination of multi-layer insulating curtains that can complement the shortcomings of the multi-layer insulating curtains currently in use and maintain and improve its warmth, and analyze the thermal properties. The heat flux means the amount of heat passing per unit time per unit area, and the higher the value, the more heat passing through the multi-layer insulating curtain, and it can be judged that the heat retention is low. The weight and thickness of multi-layer insulation curtains were found to be highly correlated with thermal insulation. In particular, insulation curtains combined with aerogel meltblown non-woven fabric had relatively higher thermal insulation than insulation curtains with the same number of insulation materials. However, the aerogel meltblown non-woven fabric is weak in light resistance and durability, and there is a problem that the production process and aerogel are scattering. In order to solve this problems, the combination of expanded aerogel non-woven fabric and hollow fiber non-woven fabric, which are relatively simple manufacturing processes and excellent warmth, are suitable for use in real farms.
        4,000원
        13.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature 60℃, the heat flux of multi-later insulating curtain is T Co.(73.1W/m2) > S Co.(119.5W/m2) > U Co.(155W/m2) > N Co.(163.1 W/m2) > P Co.(177.7W/m2). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.
        4,000원
        14.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 방울토마토 재배 단동온실에 공기순환팬을 설치하고 공기순환팬이 온실 내 온도 및 습도 분포, 에너지소비량에 미치는 영향을 분석하였다. 공기순환팬은 날개 크기 230mm의 Stainless 팬으로, Lee 등(2016)의 연구결과를 참고하여 시험구 온실에 9m 간격으로 총 18 대를 설치하였다. 온실 내부 온습도는 온실 길이방향으 로 4등분하여 1/4 지점과 3/4 지점의 중앙에 센서를 설치하고 0.8m, 1.8m 높이 2곳의 온습도를 난방을 주로 하는 야간(오후 6시~다음 날 오전 7시)에 5분 간격으로 측정하였다. 에너지소비량은 각 온실에 위치한 온수펌프의 유량, 온수 출수부와 환수부의 온도차를 측정하여 계산하였다. 공기순환팬을 사용하지 않았을 때 측점 간 온도차 및 습도차의 평균값은 0.75oC, 2.19%였으며 공기 순환팬 사용 시 측점 간 온도차 및 습도차의 평균값은 0.42oC, 1.27%로 감소하였다. 공기순환팬 설치 온실과 미설치 온실의 누적 에너지소비량은 각각 4,673kWh, 4,009kWh로 공기순환팬 설치 온실에서 약 14.2%의 에너지를 적게 소모하였다. 이러한 결과로 보아 온실 내 공기순환팬 사용은 공기를 지속적으로 교반시켜 주어 온실 전체의 온도 및 습도를 균일하게 만들고, 공기의 온도가 빠르게 변하지 않도록 해주어 난방 장치의 가동 시간과 에너지소비량을 줄일 수 있다.
        4,000원
        15.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a hot water pipe and a blowing fan were combined for developing zone heating technology for cherry tomato. The concept of this system was that hot air was firstly made by hot water pipe in one layer plastic duct and then a blowing fan made the hot air formed in a duct discharge through a duct hole to a shoot apex or a flower cluster which was temperature-sensitive part of cherry tomato. This system mainly consisted of hot water boiler, thermal tank, heat radiation plastic duct with the function of moving up and down electrically depending on the height of shoot apex. Developed system was applied to the cherry tomato greenhouse located in Jangam Chungcheongnamdo from Dec. 28, 2015 to Feb. 16, 2016 and compared with conventional entire space heating system of cherry tomato greenhouse and looked into cumulative yield for the estimate of growing state and energy saving rate from the conventional consumed energy. The result showed that cumulative yield was 3% higher and consumed energy was 32% lower than those of control greenhouse. The average temperature of shoot apex zone was 0.4~1.1℃ higher and the average relative humidity of shoot apex zone was 2,2~2.3% lower than those of entire space during night time in a shoot apex zone heating greenhouse and the average temperature of shoot apex zone was 0.7~1.4℃ lower and the relative humidity of shoot apex zone was 2.9~8.3% higher than those of entire space during night time in a entire space heating greenhouse.
        4,000원
        16.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 폭 7m, 길이 25m, 동고 3.2m의 토마토를 재배하는 온실에 공기순환팬을 설치하고 순환팬이 온실 내 온도 및 습도 분포에 미치는 영향을 조사하였다. 기존의 순환팬 설치 기준(ASAE, 1997)을 참고하여 시험 온실에 순환팬 10대를 2열 및 다른 방향으로 설치하여 18시부터 다음날 8시까지 온실 내 온습도를 측정하였다. 온실 내 온습도는 온실을 9개의 격자망으로 나눈 후 온실 중앙부에서는 0.7m, 1.7m 및 2.7m 높이, 온실 좌우 측에는 0.7m, 1.7m 높이에 센서를 설치하였다. 공기순환 팬을 사용하지 않았을 때 온실 상하부의 온도 및 습도의 평균값은 14.7oC, 74.8%와 13.0oC, 85.6%로 온습도 차는 평균적으로 1.7oC, 10.8% 발생하였다. 공기순환팬 10대를 2열 및 다른 방향으로 설치하여 운용했을 때 온실 상하부의 온습도는 14.6oC, 75.9%와 14.5oC, 79.1% 로 온습도 차는 각각 0.1oC, 3.2%였으며 순환팬을 사용 하지 않았을 때와 비교하여 온실 상하부의 온도 및 습도 차가 감소하였다. 순환팬을 6대 및 5대로 줄여서 운용했을 때 온실 상하부의 온습도 차는 각각 0.3oC, 3.4%와 0.3oC, 4.0%로 나타나 순환팬 10대를 사용했을 때와 비슷한 효과를 보였다. 순환팬 10대를 2열 및 같은 방향으로 설치했을 때의 온실 상하부의 온습도 차는 0.5oC, 4.9%로 팬을 다른 방향으로 설치했을 때보다 온습도 차가 크게 나타났다. 온실 좌우측면, 전후면의 온습도 차를 살펴보면 순환팬을 사용하지 않았을 때 좌우 측면의 온습도 차는 0.3oC, 1.7%로 작아 팬을 사용했을 때와 큰 차이가 없었으나 순환팬을 사용하지 않았을 때 1.0oC, 4.2%로 나타났던 전후면의 온습도 차는 순환팬을 사용함으로써 감소하였다. 이는 공기순환팬이 온실 내 공기를 순환시켜 온풍난방 시 상부에 정체된 더운 공기나 열손실로 인해 온도가 다른 공기를 교반시킴으로써 온도 및 습도 차가 감소한 것이다. 폭 7m, 길이 25m, 동고 3.2m인 단동온실에서 날개 크기 230mm, 풍량 11m3/min의 공기순환팬을 사용하고자 할 때는 순환팬 5대를 2열로 설치하되 각 열을 방향을 다르게 하고 9m 간격으로 설치하여 운용하는 것이 가장 경제적이고 효과적일 것이다.
        4,000원
        17.
        2016.10 구독 인증기관 무료, 개인회원 유료
        Results of this study appeared chicken breeding households nationwide in 3,323 households. Local broiler breeding two numbers are Jeonbuk>Chungnam>Jeonnam> Gyeonggi>Gyeongbuk>Chungbuk>Gyeongnam>Gangwon>Jeju appeared in other net. Local chicken breeding numbers are Chungnam>Jeonbuk>Gyeongbuk>Jeonam> Chungbuk>Gyeongnam>Gangwon appeared in order. Livestock mortality is 482,000 numbers in 2012, and 911,000 numbers in 2014 and 2.494,000 numbers in 2015, a significant increase year by to 4.298,000 numbers in 2016. Insurance 11.2 billion in 2012, 49.8 billion in 2013, 21.2 billion in 2014, 74.5 million won was paid in 2015 is expected to be paid in 2016, 128.4 billion won. A study on the future, preventing livestock damage caused by high temperature will have to continue.
        4,000원
        18.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, environmental new feeding and management system that are suitable for hot and cool water supply and floor heating system was developed and analyzed the effect for productivity and meat quality with supplying hot water in winter, the results were as follow as. HWSS was not affecting improvement with broiler productivity in initial time. Supplying hot water made the temperature inside broiler barn not go down rapidly as time went by from former term to latter term and continuous supplying hot water made boiler be adapted properly to the temperature and humidity of breeding environment that was requiring at its own growth phases. With unsaturated fatty acid / saturated fatty acids, HWSS was higher in broiler breast but CWSS was higher in the leg. With AST, ALT in blood, HWSS is higher than CWSS but with neutral lipid, protein, glucose, albumin, cholesterol, HWSS is higher than CWSS. Water circulation heating system gave an impact on meat quality and PH showed a higher in CWSS system. Also, redness and yellowness of the meat color was confirmed to be greater in HWSS. It was proved that the temperature difference of drinking water affected farm productivity, the blood and flesh quality, therefore, that could be estimated to be utilized successfully, if that should be used appropriately for productivity improvement according to the week-old of growth phase.
        4,000원
        19.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of these studies are to provide a basic data for the development of high-efficiency environmental improvement system that can parallel the cage(henhouse) and hot and cold potable water supply for increased summer heat stress relief and winter feed efficiency by optimal design. The cage area is 273m2. The air-to-water heat pump with 20RT capacity was used for heating and cooling. The control was used as an electric hot water boiler. For calculating heating load determined the cage size, materials, heat pump capacity, heating capacity, heat storage tank, and drinking water tank capacity etc. Therefore the capacity of heat pump was set-up using 20RT. The cage was built as a prefabricated panels henhouse of 13×21×4.5 m (width×depth×height). The heat storage tank and was drinking water tank capacity was constructed 3tons and 10 tons, respectively. In future, it is thought that optimal design considering the cage size and hen breeding scale is required.
        4,000원
        20.
        2015.11 구독 인증기관 무료, 개인회원 유료
        In this study, to develop high-efficiency environmental improvement system that can be combined with hot and cold potable water supply to poultry air conditioning for the summer increase heat stress relief and winter feed efficiency through optimal design hwihan The aim of this study was to provide basic data. As a cage the size of the system installed is 100m2 test capacity 20RT district heating and cooling of air-to-water heat pump and the control was composed of electric hot water boilers. First of cage sizes for heating load design, materials, heat pump capacity, air capacity, storage tank, drinking water tank capacity, etc. were determined. The capacity of the heat pump was set to 20RT cage captive birds are erected as vertically and horizontally × height × (13 × 21 × 4.5m). Storage tank 3 tons and capacity of 10 tons potable water tank was designed. In the future, the size of the cage, designed according to the best breeding two numbers are needed.
        4,000원