검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 68

        3.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the humidity control effect of a counter-flow ventilator was analyzed in a greenhouse with high relative humidity at night in the winter season. A case of the counter-flow ventilator was 0.96 × 0.65× 0.82(W× D × H, m) and there were heat transfer element and two fans for air supply and exhaust in the counter-flow ventilator. Two counter-flow ventilators were used in this study and the setting humidity of the ventilators was 80%. The temperature and relative humidity at night(18:00-8:00) in the greenhouse were measured. In a greenhouse without a counter-flow ventilator, the average temperature and humidity was 14.9°C, 82.8%, respectively. When the counter-flow ventilator was operated, the corresponding averages were 15.1°C, 79.9%. The independent sample t test of monthly temperature and relative humidity showed no difference in temperature, and a significant difference in relative humidity with 1% of the significance level. Therefore, using the counter-flow ventilator helps to control relative humidity in greenhouse and increase yield.. And further research considering the pros and cons of using the counter-flow ventilator is needed.
        4,000원
        4.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The results of internal temperature. productivity and immunity analysis of the laying hen house by the thermal environment and the supply of cold drinking water were as follows. The external temperature was changed from the minimum of 18℃ at night and the maximum of 36℃ during the day, and the internal temperature of the laying hens varied from 20~31℃. Thermal imaging analysis showed that the body temperature of the laying hen decreased by 2.4℃ with the supply of drinking water. The laying hen amount increased 2.36g and laying hen rate increased 3.62%p. Albumin increased 6.1%, decreased AST 15%, and decreased cholesterol 12.7%. Immune activators increased and T cells and B cells increased to increase immunity.
        4,000원
        5.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        With the recent accelerated policy-making and interests in new renewable energy, plans to develop and supply the new renewable energy have been devised across multiple regions in Korea. Solar energy, in particular, is being applied to small-scale power supply in provincial areas, as solar cells are used to convert solar energy into electric energy to produce electric power. Nonetheless, in the case of solar power plants, the need for a large stretch of land and considerable sum of financial support implies that the planning step should take into consideration the most suitable meteorological and geographical factors. In this study, the proxy variables of meteorological and geographical factors associated with solar energy were considered in analyzing the vulnerable areas regarding the photovoltaic power generation facility across the nation. GIS was used in the spatial analysis to develop a map for assessing the optimal location for photovoltaic power generation facility. The final vulnerability map developed in this study did not reveal any areas that exhibit vulnerability level 5 (very high) or 1 (very low). Jeollanam-do showed the largest value of vulnerability level 4 (high), while a large value of vulnerability level 3 (moderate) was shown by several administrative districts including Gwangju metropolitan city, Jeollabuk-do, Chungcheongbuk-do, and Gangwon- do. A value of vulnerability level 2 (low) was shown by the metropolitan cities including Daegu, Ulsan, and Incheon. When the 30 currently operating solar power plants were compared and reviewed, most were found to be in an area of vulnerability level 2 or 3, indicating that the locations were relatively suitable for solar energy. However, the limited data quantity for solar power plants, which is the limitation of this study, prevents the accuracy of the findings to be clearly established. Nevertheless, the significance of this study lies in that an attempt has been made to assess the vulnerability map for photovoltaic power generation facility targeting various regions across the nation, through the use of the GIS-based spatial analysis technique that takes into account the diverse meteorological and geographical factors. Furthermore, by presenting the data obtained for all regions across the nation, the findings of this study are likely to prove useful as the basic data in fields related to the photovoltaic power generation.
        4,300원
        6.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 국내의 고온다습한 하절기에 산란계에 음용수 온도가 생산성, 호르몬 농도 및 혈액성상에 미치는 영향을 구명하고자 실행하였다. 52주령 하이라인 갈색종 산란계 432수를 3개 처리구와 8반복으로 반복당 18수씩 케이지 사육장(550 cm2/수)에 배치하였고, 처리구별로 14.5, 24.0 및 32.5℃의 음용 수를 4주간 급수하였다. 산란계의 생산성은 산란율과 난중을 매일 조사하여 계산하였고, 호르몬, 혈액 성상 및 계란품질은 사양실험 종료 후 채집하여 분석하였다. 본 연구결과 산란율과 1일 산란양은 14.5℃ 의 급수구에서 유의적으로 개선되었고(p<0.05), 사료섭취량과 난중은 14.5와 24.0℃ 급수구에서 32.5℃ 에 비하여 현저히 증가하였다(p<0.05). 계란의 난백높이와 호우유닛은 음용수 온도에 따른 처리구간 통계적 차이가 없었다. 난각강도는 14.5℃ 급수 처리구에서 증가하였고(p<0.05) 난각두께도 개선되는 경향을 보였지만 처리구간에 통계적 차이는 없었다. 또한 혈청과 간의 GH와 IGF-I 농도는 32.5, 24.0 및 14.5℃ 급여구 순서로 증가하였고(p<0.05), 코티코스테론은 감소되었는데 14.5℃에서 가장 개선되었다(p<0.05). 이외에도 혈중 AST와 콜레스테롤은 14.5℃의 음용수 처리구에서 24.0과 32.5℃에 비하여 유의적으로 감소하였고(p<0.05), HDL콜레스테롤, 단백질 및 글루코오스는 처리구간에 통계적 차이가 없 었지만, 혈중 중성지방은 14.5℃처리구에서 현저하게 감소되었다(p<0.05). 그러므로 여름철 14.5℃의 음용수를 급여하면 산란계에서 고온스트레스를 저감하므로서 생산성, 계란품질 및 혈액성상을 개선하였다.
        4,000원
        8.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry ‘Seolhyang’ using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at 18 ~ 22oC. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above 30oC. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone 20oC+inside greenhouse 5oC) and crown local heating(crown 20oC+inside greenhouse 5oC) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse 9oC). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.
        4,000원
        9.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The drinking water supply system applicable to the laying hen consists of air-water heat pumps, drinking water tanks, heat stroage tank, circulation pumps, PE pipes, nipples, and control panels. When the heat pump system has power of 7.7 to 8.7 kW per hour, the performance coefficient is between 3.1 and 3.5. The supply temperature from the heat pump to the heat stroage tank was stabilized at about 12±1°C, but the return temperature showed a variation of from 8 to 14°C. Stratified temperature in the storage tank appeared at 12.°C, 13.5°C and 14.4°C, respectively. The drinking water supply temperature remained set at 15°C and 25°C, and the conventional tap water showed a variation for 23°C to 30°C. As chickens grow older, the amount of food intake and drinking water increased. y = -0.0563x2 + 4.7383x + 8.743, R2 = 0.98 and the feed intake showed y = -0.1013x2 + 8.5611x. In the future, further studies will need to figure out the cooling effect on heat stress of livestock.
        4,000원
        11.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 고온다습한 하절기에 음수의 형태가 닭의 생산성, 육질, 혈액의 성상에 미치는 영향을 구명하고자 실행하였다. 8일령 로스종 360수를 4개 처리구인 수돗물, 이온수, 냉수 및 냉이온수(냉수+이온수)로 처리구당 6반복으로 평사에 수용하여 5주령까지 급수하였다. 계사내부 평균 온도와 습도는 30.9℃와 74.0%였으며, 수돗물의 평균온도는 29.5℃였다. 이온수는 정전기를 이용하여 물을 이온화하였고, 냉수는 15℃로 고정하여 급수하였다. 증체량, 사료섭취량 및 사료요구율은 주간으로 측정하였으며, 혈액과 계육 샘플은 실험 종료시에 채취하였다. 사육전기 21일령에 증체량은 수돗물 처리구에서 다른 처리구에 비하여 낮았지만 통계적 차이는 없었으며, 사육후기의 35일령에 이온수, 냉수, 냉이온수 처리구에서수돗물 처리구에 비하여 현저하게 높게 나타났다(p<0.01). 사료섭취량은 증체와 동일하게 사육전기에는 처리구간에 일관적 차이가 없었지만 사육후기에 수돗물 처리구에 비하여 다른 처리구에서 매우 개선 되는 경향을 보였다(p<0.01). 사료요구율은 사양실험 전기간에서 이온수, 냉수 및 냉이온수 처리구에서 매우 개선되었다(p<0.05). 계육의 가슴살에서 명도는 수돗물 처리구에서 높게 나타났으며, 적색도는 낮은 경향을 보였다. 황색도는 일관성이 없었지만 pH는 수돗물 처리구에서 다른 처리구에 비하여 낮게 나타났다(p<0.05). 조리감량은 이온수, 냉수 및 냉이온수 처리구에서 수돗물에 비하여 매우 낮았지만(p<0.05) 연도는 높은 경향을 보였다. 혈중 알부민과 단백질은 처리구간에 차이가 없었지만, 중성지방은 이온수, 냉수 및 냉이온수 처리구에서 낮은 경향을 보였다(p<0.05). 혈중 포도당은 처리구간에 차이가 없었지만 HDL 콜레스테롤은 이온수, 냉수, 냉이온수 처리구에서 수돗물 처리구에 비해 현저하게 높게 나타났다(p<0.05). 본 실험 결과 혹서기 육계에 냉이온수 급수는 생산성 및 육질을 개선하고 혈중HDL을 높게 하였다.
        4,000원
        13.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to effectively utilize thermal energy, we analyzed the performance of the high efficiency latent heat storage system which can be used for greenhouse heating by using the developed phase change material. The system consists of hot water boiler, heat storage material, heat storage box, heat storage tank, circulation pump, control panel, and storage material. As a result, the latent heat and latent heat temperature of sodium acetate hydrate as latent heat storage material are 231.6 ~ 264.8kJ/kg, 54.95 ~ 55.48℃. As the number of cooling and heating increased, the latent heat temperature showed a slight change, but the latent heat decreased 33.1kJ/kg as the number of repetition increased. In the case of sodium acetate hydrate, large supercooling phenomenon was observed, and it was found that mixing of additives such as nucleating agent, thickener and supercooling agent can control the supercooling more effectively. The consumption of kerosene decreased until the temperature of the heat storage tank was raised to the set temperature by the closed circuit for 4 hours in the initial stage of the boiler operation. The heat exchange rate according to the change of the flow rate was maintained at the set temperature inside the heat storage tank after 4 hours of operation, Consumption was high. As the flow rate increased, the inlet and outlet temperature difference decreased, the heat exchange rate increased, and the heat exchange efficiency was in the range of 57.4 ~ 60.5%.
        4,000원
        14.
        2018.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 풍환경에 따른 열손실을 분석하는데 있어 필요한 풍속 기초자료를 제공하기 위하여 주요 11개 해안지역 중 온실밀집지역을 선정하여 기상환경 및 온실 방위를 조사 분석하였다. 대상지역은 난방온실 재배면적과 풍환경 기준으로 선정하였고 온실밀집지역은 50,000m2 이상인 지역을 대상으로 하였다. 11곳의 기상자료 중 기온,풍속, 풍향을 대상으로 30년간 자료를 수집하여 분석하였고 기온은 최저, 평균, 최고 기온을 나누고 풍속 및 풍향 기준은 기상청 분석 기준을 적용하였다. 온실의 배치방향은 형태가 대칭인 점을 감안하여 0~180o 범위로 자료를 수집하였다. 또한, 각 지역마다 풍향이 있으며 온실길이방향을 기준으로 하였을 때 적용되는 풍향은 달라질 수 있으며 이를 상대풍향으로 지칭하고 중복되는 점을 고려하여 0~90o 범위로 자료를 수집하였다. 11개 지역의 기온은 중부지방에 있는 보령, 영광 지역과 남부지방에 있는 9개 지역의 기온차이가 구분되었다. 중부해안 대상지역은 1월 최저기온은 약 3~4oC 정도 온 도가 높은 것을 확인할 수 있었고 평균기온은 약 3oC 정도 높았으며 월별 기온 중 최저기온을 선정할 때에 1 월 기온을 고려해야 되는 것으로 판단된다. 대상지역의 주풍향에 대한 월별 차이는 크게 발생하지 않았으며 풍향 분포에 따라 지역별로 서해안측, 서해 및 남해 경계 해안측, 남해안측으로 구분되어졌다. 풍속은 영광을 제외 한 10개 지역은 월간 풍속 포차이가 크게 발생하지 않는 것으로 판단된다. 대상지역의 온실의 방향은 길이방향 기준으로 분석하였으며 보령과 영광, 남해 지역은 60%이상 집중되어 있는 방향이 존재하였고 해남, 통영 지역은 약 90% 집중되어있는 방향이 존재하였으며 이는 경지정리로 인하여 방향이 편향되어있는 지역이 존재하는 것으로 판단된다.
        4,000원
        15.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        쓰레기 소각장이나 산업체의 폐열을 농업에 활용한 사례는 몇몇 있었다. 그러나 온배수를 농업에 활용한 사례는 전무하였으며, 치어, 종패 등을 양식하는 수산업이 대부분이었다. 본 연구에서는 화력발전소의 온배수(폐열)를 열원으로 이용하는 120 RT 규모의 냉난방시스템을 제주특별자치도 서귀포시 안덕면 소재의 5,280m2 아열대 작물(망고) 재배 온실에 설치, 10월에서 다음해 2월까지 약 5개월 동안 난방을 실시하여 난방에너지 비용 절감 효과 등 분석하였다. 난방에너지 비용 절감효과는 면세경유에 대하여 87%이였으며, 또한 발전소의 온배수를 에너지원으로 재활용함으로 서 62%의 이산화탄소 배출 저감 효과를 얻었다. 본 연구를 계기로 2015년에 해수가 수열에너지 분야로 재생에너지에 포함되었다. 해수의 표층의 열을 히트펌프를 사용하여 변환시켜 얻은 에너지라는 수열에너지 분야의 기준과 범위를 볼 때, 이는 온배수가 재생에너지에 포함되었다고 말해도 과언이 아닐 것으로 사료된다. 그 이유는 온배수도 해수임에도 불구하고 온도가 일반 해수 보다 7~8oC 높아, 일반 해수를 히트펌프의 열원으로 이용하는 것보다 온배수를 열원으로 이용했을 때 히트펌프의 성능이 높기 때문이다. 또한 같은 해 농식품부의 폐열 재이용 시설 지원 사업이 발표되어, 발전소 온배수뿐만 아니라 산업체와 소각장의 폐열을 농업에 활용하면 지원을 받을 수 있게 되었다. 이 사업에 의하여 2015년 당진시, 하동군, 제주시, 곡성군이 선정되었으며, 2016년 태안군, 서귀포시 등이 선정되어, 2016년 말 곡성군과 제주시가 공사를 완료, 농업에 폐열을 활용하고 있으며(제주시는 발전소, 곡성군은 산업체 폐열을 이용하고 있음), 기타 지역은 추진 중이다.
        4,000원
        17.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims at providing a basic data for the development of high energy efficient environment system in the cage (poultry buildings) and cold potable water supply to reduce the summer heat stress. For this study, the cage area size was 273m 2 and the air-to-water heat pump capacity was 20RT for heating and cooling. As the result of this study, the temperature of the drinking water supplied by heat pump was maintained at the set temperature of 15℃. However, the water temperature of control was 23~28 ℃ due to the effect of outside temperature. The average internal cage temperature was 25.3 ℃ in the test group and 28.1 ℃ in the control group, which was 2.8 ℃ higher than that of the control group. The relative humidity was 76.2% in the test group and 75.0% in the control group. The broiler drank 23.2 L / day in the test group and 21.5 L / day in the control group. Daily feed intake was 937 g and and 725 g in the cold water and control water respectively. The feed intake of 212 g was higher than that of cold water. The feeding rates were 1.8 and 1.9. Body weights were 1,523 g and 1,164 g in the cold water and control water respectively. The weight gain was 359 g in the test group fed with cold water and 392 g in the control group. When compared with the control group, the mortality rate was reduced by 84% in the cold water feeding test. It is necessary that future research will continue to reduce the incidence of such livestock accidents.’.
        4,000원
        18.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a hot water pipe and a blowing fan were combined for developing zone heating technology for cherry tomato. The concept of this system was that hot air was firstly made by hot water pipe in one layer plastic duct and then a blowing fan made the hot air formed in a duct discharge through a duct hole to a shoot apex or a flower cluster which was temperature-sensitive part of cherry tomato. This system mainly consisted of hot water boiler, thermal tank, heat radiation plastic duct with the function of moving up and down electrically depending on the height of shoot apex. Developed system was applied to the cherry tomato greenhouse located in Jangam Chungcheongnamdo from Dec. 28, 2015 to Feb. 16, 2016 and compared with conventional entire space heating system of cherry tomato greenhouse and looked into cumulative yield for the estimate of growing state and energy saving rate from the conventional consumed energy. The result showed that cumulative yield was 3% higher and consumed energy was 32% lower than those of control greenhouse. The average temperature of shoot apex zone was 0.4~1.1℃ higher and the average relative humidity of shoot apex zone was 2,2~2.3% lower than those of entire space during night time in a shoot apex zone heating greenhouse and the average temperature of shoot apex zone was 0.7~1.4℃ lower and the relative humidity of shoot apex zone was 2.9~8.3% higher than those of entire space during night time in a entire space heating greenhouse.
        4,000원
        19.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 폭 7m, 길이 25m, 동고 3.2m의 토마토를 재배하는 온실에 공기순환팬을 설치하고 순환팬이 온실 내 온도 및 습도 분포에 미치는 영향을 조사하였다. 기존의 순환팬 설치 기준(ASAE, 1997)을 참고하여 시험 온실에 순환팬 10대를 2열 및 다른 방향으로 설치하여 18시부터 다음날 8시까지 온실 내 온습도를 측정하였다. 온실 내 온습도는 온실을 9개의 격자망으로 나눈 후 온실 중앙부에서는 0.7m, 1.7m 및 2.7m 높이, 온실 좌우 측에는 0.7m, 1.7m 높이에 센서를 설치하였다. 공기순환 팬을 사용하지 않았을 때 온실 상하부의 온도 및 습도의 평균값은 14.7oC, 74.8%와 13.0oC, 85.6%로 온습도 차는 평균적으로 1.7oC, 10.8% 발생하였다. 공기순환팬 10대를 2열 및 다른 방향으로 설치하여 운용했을 때 온실 상하부의 온습도는 14.6oC, 75.9%와 14.5oC, 79.1% 로 온습도 차는 각각 0.1oC, 3.2%였으며 순환팬을 사용 하지 않았을 때와 비교하여 온실 상하부의 온도 및 습도 차가 감소하였다. 순환팬을 6대 및 5대로 줄여서 운용했을 때 온실 상하부의 온습도 차는 각각 0.3oC, 3.4%와 0.3oC, 4.0%로 나타나 순환팬 10대를 사용했을 때와 비슷한 효과를 보였다. 순환팬 10대를 2열 및 같은 방향으로 설치했을 때의 온실 상하부의 온습도 차는 0.5oC, 4.9%로 팬을 다른 방향으로 설치했을 때보다 온습도 차가 크게 나타났다. 온실 좌우측면, 전후면의 온습도 차를 살펴보면 순환팬을 사용하지 않았을 때 좌우 측면의 온습도 차는 0.3oC, 1.7%로 작아 팬을 사용했을 때와 큰 차이가 없었으나 순환팬을 사용하지 않았을 때 1.0oC, 4.2%로 나타났던 전후면의 온습도 차는 순환팬을 사용함으로써 감소하였다. 이는 공기순환팬이 온실 내 공기를 순환시켜 온풍난방 시 상부에 정체된 더운 공기나 열손실로 인해 온도가 다른 공기를 교반시킴으로써 온도 및 습도 차가 감소한 것이다. 폭 7m, 길이 25m, 동고 3.2m인 단동온실에서 날개 크기 230mm, 풍량 11m3/min의 공기순환팬을 사용하고자 할 때는 순환팬 5대를 2열로 설치하되 각 열을 방향을 다르게 하고 9m 간격으로 설치하여 운용하는 것이 가장 경제적이고 효과적일 것이다.
        4,000원
        20.
        2016.10 구독 인증기관 무료, 개인회원 유료
        Results of this study appeared chicken breeding households nationwide in 3,323 households. Local broiler breeding two numbers are Jeonbuk>Chungnam>Jeonnam> Gyeonggi>Gyeongbuk>Chungbuk>Gyeongnam>Gangwon>Jeju appeared in other net. Local chicken breeding numbers are Chungnam>Jeonbuk>Gyeongbuk>Jeonam> Chungbuk>Gyeongnam>Gangwon appeared in order. Livestock mortality is 482,000 numbers in 2012, and 911,000 numbers in 2014 and 2.494,000 numbers in 2015, a significant increase year by to 4.298,000 numbers in 2016. Insurance 11.2 billion in 2012, 49.8 billion in 2013, 21.2 billion in 2014, 74.5 million won was paid in 2015 is expected to be paid in 2016, 128.4 billion won. A study on the future, preventing livestock damage caused by high temperature will have to continue.
        4,000원
        1 2 3 4