검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 23

        1.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to apply with an air duct for the cooling and a utilizing cultivating method that uses the fruiting node and the defoliation to the high-temperature vertical and hydroponic cultivation of the oriental melon. The lower fruiting node (LF) was to remove all third vines generated from 5 nodes of a secondary vine. The higher fruiting node (HF) was fruiting on the third vine generated from a first node of the third vine. The direction of the stem string; upward (UW), downward (DW). Four treatment conditions were applied with the LF-UW, LF-DW, HF-UW (control), and HF-DW. The leaf age of melon leaves was measured for photosynthesis at 3 days intervals, and the fruit characteristic was conducted on 79 fruits in each treatment. The photosynthesis rate steadily increased after leaf development, reaching 20.8 μmol CO2·m-2·s-1 on the 10 days, gradually increasing to 21.3 μmol CO2·m-2·s-1 on the 19 days, and reaching 23.4 μmol CO2·m-2·s-1 on the 32 days. After that, it lowered to 16.8 μmol CO2·m-2·s-1 on the 38 days and dropped significantly to 7.6 μmol CO2·m-2·s-1 on the 47 days. As a result of the fruit characteristics by fruiting nodes, the treatments of the fruit length was 12.6-13.4 cm, respectively, which was significant, and the fruit width was 7.9- 8.6 cm, respectively, was not significant. The soluble content ranged from 12.9 to 15.7°Brix, and the significance of all treatments, and higher than of LF-DW and HF-UW. The photosynthesis rate of melon leaves was good until 32 days after leaf development, but after that, the rate decreased. As for fruit quality, it was conformed that melons can be cultivated at the LF because the fruit enlargement and soluble content dose not decrease even when set at the LF. Results indicated that those can be used for LF and defoliation in the development of vertical and hydroponic cultivation method in high-temperature season.
        4,000원
        2.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 양액재배 시 발생되는 폐양액의 적절한 농업 적 이용방안을 강구하기 위해 폐양액의 비료 효과시험, 토양 컬럼 시험, 그리고 작물 재배시험을 수행하였다. 폐양액의 비 료 효과시험은 무기질소를 기준으로 질소비료와 폐양액의 토 양 처리에 따른 열무의 생육특성과 토양의 화학적 특성을 조 사하였다. 폐양액 비료 효과시험과 작물 재배시험을 위한 토양에 대한 폐양액의 처리는 무처리; A, 질소비료 100%; B, 질 소비료 70%+폐양액 30%; C, 질소비료 50%+폐양액 50%; D, 질소비료 30%+폐양액 70%; E 총 5개 처리구로 하였다. 토양컬럼 시험을 위한 토양에 대한 폐양액의 처리는 무처리, 질 소비료 100%, 폐양액 50%+질소비료 50% 3개 처리구로 하 였다. 폐양액의 화학성은 pH 6.0, EC 2.4dS·m-1, 총인(T-P) 28mg·L-1, 암모늄태 질소(NH4-N) 5.0mg·L-1, 질산태 질소 (NO3-N) 301mg·L-1로 나타났다. 토양의 화학성은 pH 5.51, EC 0.31dS·m-1, 유기물 2.08g·kg-1, 질산태 질소 9.64mg·kg-1, 암모늄태 질소 3.20mg·kg-1으로 나타났다. 질소비료 50% 이 하와 폐양액 50% 이상의 비율이 열무 생육에 효과가 높은 것 으로 나타났다. 폐양액을 질소비료와 함께 혼합하여 적용한 C-E 처리구에서 토양의 이화학성은 질소비료만을 적용한 B 처 리구와 통계적으로 유의한 차이가 없었다. 토양컬럼 시험 결과 질소비료 100%와 폐양액 50%+질산비료 50% 처리구의 NO3 와 NH4의 농도는 큰 차이가 없는 것으로 나타났다. 폐양액을 화 학비료의 표준시비량을 기준으로 이용하여 토양에 처리하면 토양 내 질소 성분의 이동과 주변의 영향은 일반 화학비료와 유 사하게 나타나는 것으로 판단된다. 열무 토경재배에 폐양액과 질소비료를 혼합하여 사용하면 폐양액의 재이용으로 환경적 부담도 줄일 수 있고, 질소비료의 사용량도 줄일 수 있어 농가에 경제적 부담 감소와 열무 생산량 증대 효과도 기대할 수 있다.
        4,000원
        3.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 ‘설향’ 딸기를 두 작기(2020-2021년, 2021 -2022년)에 걸쳐 재배하면서 외부 광환경과 생육도일온도 가 작물 생산량에 미치는 영향을 분석하였다. 2년 동안 온실 내 환경 관리, 양액 관리 등은 동일하게 하였다. 재배기간 중 주 간의 온실 온습도는 두 작기에서 유사하게 관리되었고, 야간 의 온습도는 통계적으로 차이가 있었으나 작물 생육 범위를 벗어나지 않았다. 일사량은 9월과 10월에 첫 번째 작기의 일 평균 일사량이 많아 누적일사량도 많았으며, 11월부터는 2월 까지는 두 번째 작기의 일사량, 3월에는 다시 첫 번째 작기의 일사량이 많은 것으로 나타나 1월부터의 누적일사량은 두 번 째 작기에서 많은 것으로 나타났다. 딸기의 최적 일장 조건인 8시간 이상의 일장이 나타난 일은 두 작기 간 큰 차이가 없었고, 변화 양상은 누적일사량의 변화와 유사하게 나타났다. 누 적일사량과 생육도일온도는 상관관계가 커 생육도일온도가 딸기의 생산량과 당도에 미치는 영향을 조사해 본 결과의 초 기의 누적일사량과 생육도일온도가 적었던 두 번째 작기에서 초기 수확량은 적었으나 누적일사량 및 생육도일온도가 증가 함에 따라 후기에 수확량이 첫 번째 작기보다 많았으며 잠재 적 최대 생산량도 큰 것으로 나타났다. 당도는 생육도일온도 가 증가함에 따라 감소하였으며, 이는 촉성딸기의 특성으로 판단된다. 추후 연구를 통해 단순 수확량뿐만 아니라 작물 생 육, 꽃눈분화 및 출뢰시기를 조사, 분석하여 생육도일온도가 작 물 생육에 미치는 영향을 다각도로 분석하는 연구도 필요하다 고 판단된다.
        4,000원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an accelerated weathering test was performed to examine the variation of thermal insulation performance according to the service life. A widely used class 1 thermal screen (matt georgette + polyethylene (PE) foam + chemical cotton + felt + matt georgette) was selected as the target thermal screen. The ultraviolet irradiation that reached the target thermal screen specimen (60 x 60cm) was 5mW/cm2. Thus, the ultraviolet irradiance was set to 5mW/cm2, and the exposure periods of accelerated weathering conditions on the specimens were set to 0, 282, 847, and 1412h. The radiation exposure periods of the weathering conditions for 0, 282, 847, and 1412h indicate the amount of ultraviolet accumulation for 0, 1, 3, and 5years, respectively. In the accelerated weathering test, the target specimens that completed each exposure phase were subjected to the hotbox test to analyze their thermal insulation performances. Consequently, the thermal insulation performance of the multi-layer thermal screen was estimated to degrade rapidly after approximately two years. In the accelerated weathering condition, a quadratic function model was used to calculate the expected service life, since it adequately described the variation in thermal insulation of the thermal screen according to time. The results showed that when the thermal insulation performance degraded by 5, 10, 20, and 30%, the expected service lives were 2.5, 3.3, 4.5, and 5.5years, respectively.
        4,000원
        5.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        모바일 기반 온실에너지 계산프로그램을 제작하기 위해 먼저 주요 단일 피복재 10종 및 보온재 16종에 대한 열관류율 측정하였다. 또한 피복 및 보온재를 이중 및 삼중으로 다층 설치할 때 열관류율 추정을 위하여 이중 설치시 24조합, 삼중설치 시 59조합에 대한 열관류율을 핫박스를 이용하여 측정하였다. 단일 피복재에서는 PE필름(0.08mm) 대비 PO필름(0.15mm) 이 가장 열관류율이 가장 작고 열절감율이 가장 큰 것으로 나타났다. 단일 보온재에서는 열관류율에서는 외피가 있는 5겹 의 다겹보온커튼이 가장 보온력이 좋은 것으로 나타났다. 또한 단일자재에 대한 열관류율 값과 열저항값을 이용한 피복 및 보온재의 다층설치시의 총 열관류율 값을 산정하였고 실측 값과의 오차를 보정하는 선형회귀식을 도출하였다. 단일재료의 열관류율값에 의한 피복 및 보온재의 다층설치시 열관류율 추정 모형을 개발한 결과 모형평가지수가 0.90(0.5 이상일 때 양호)으로 나타나 추정치가 실측치를 매우 잘 재현 하고 있는 것으로 나타났다. 또한 시험온실을 통한 실증시험결과 예측된 열절감율이 실측치보다 상대오차 2%로 작게 나타나는 것으로 평가되었다. 이러한 연구결과를 기반으로 모바일 기반의 온실 에너지계산 프로그램을 개발하였다. 이 프로그램은 HTML5 표준 웹 기반 모바일 웹 애플리케이션으로 구현하였으며 N-Screen 지원을 통해 다양한 모바일 장치 및 PC 브라우 저에서 동작이 가능하게 제작되었다. 또한 온실 피복(12종) 및 보온재(16종)의 조합별 열관류율 및 난방부하계수를 제공 하여 농민이 모바일로 온실 위치, 형태 및 피복·보온재 등을 반영한 최대 주야간 냉난방부하 및 기간 난방부하를 산정할 수 있다. 대상 온실의 에너지 소비량에 대한 평가가 가능하며 온실의 지역 및 형태에 따라 피복 및 보온재의 최적 선택으로 에너지 절감형 온실 설계가 가능할 것으로 판단되었다.
        4,000원
        6.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 ‘설향’ 딸기의 관부를 부분 난방하고 양액을 온수로 공급하면서 관행 재배 방식에 비해 온실 공간 온도를 낮게 관리하는 딸기 부분 난방 시험을 수행하였다. 정식 후 11월까지는 특별한 처리가 없어 대조구, 시험구 모두 온실 내 환 경이 유사하게 관리되었으며 관부 난방 및 온수 양액을 공급 하기 시작한 12월부터는 야간의 온실 온도, 관부 온도 및 베드 온도가 차이를 보였다. 12월의 온실 야간 평균 온습도는 대조구 7.1℃, 87.2%, 시험구 5.7℃, 88.7%로 시험구의 온도가 낮았으나 관부 난방을 수행함으로써 시험구 온실의 관부 및 베드의 온도를 9.3℃, 12.7℃로 유지하였고, 대조구 온실의 관부 및 베드 온도 7.9℃, 10.8℃보다 높게 관리할 수 있었다. 시험기간 내에서 시험구 온실의 딸기 관부 및 베드 온도는 대조구에 비해 모두 약 2.0℃ 가량 높게 유지되는 것으로 나타났다. 주간에는 온수 양액을 공급함으로써 지하수를 이용했을 때보 다 평균 8.7℃ 높은 온도 양액을 공급할 수 있었고 이로 인해 베드 온도도 약 5.0℃ 가량 높게 나타났다. 시험구에서는 시험 기간 동안 온실 난방, 관부 난방 및 온수 양액 공급에 총 9,475.7×10 3 kcal의 에너지를 소비하였고 대조구에서는 온실 공간 난방에 총 16,847×10 3 kcal의 에너지를 소비하여 시험구에서 대조구 대비 약 43.8%의 에너지 절감 효과를 확인할 수 있었다. 시험구에서 딸기 관부의 온도를 높게 관리함으로써 작물의 생육을 촉진시킬 수 있었고 그로 인해 정식 후 초세가 대조구에 비해 좋지 않았던 시험구의 딸기가 25주 후에는 대조구와 생육적인 면에서 큰 차이가 없는 것으로 나타났다. 딸기의 수확량은 초세가 좋았던 대조구에서 1화방의 수확량이 시험구에 비해 많았으나 2화방, 3화방에서는 관부의 온도를 높게 관리한 시험구의 수확량이 더 많았다. 3월 말까지의 주당 수확량은 시험구 412.7g/plant, 대조구 393.3g/plant로 유의미한 차이는 없었으나 시험구가 대조구에 비해 4.9% 많이 나온 것으로 보아 딸기의 온도 민감부인 관부의 온도를 높게 관리하는 것이 딸기 생육과 생산성에 영향을 미치는 것으로 판단된다.
        4,000원
        7.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 PO필름과 PE필름을 온실의 피복재로 적용하였을 때 작물 수량 증대 및 에너지 절감에 미치는 영향을 조사하였다. 시험온실은 국립원예특작과학원 시설원예연구소 내에 위치한 단동온실(1-1W) 2동(B21, B23)과 2연동온실(1-2W 형) 2동(B15, B16)을 사용하였다. 단동온실의 규격은 폭 7.2m, 길이 30m, 측고 1.5m, 동고 3.6m 이고, 연동온실의 규격은 폭 8m, 길이 40m, 측고 3.1m, 동고 5.8m의 온실로서 이 중 골조로 된 아치형 표준온실이다. 동절기 시험을 위하여 PO 필름(외피 0.15mm, 내피 0.10mm)을 단동과 연동의 온실 피복재로 사용하였으며 대조구 온실로서 PE필름(외피 0.15mm, 내피 0.10mm)을 단동과 연동에 설치하였다. 시험작물은 완숙토마토 ‘해피니스’를 토양재배 하였고 2019년 12월 3일에 정식하여 2020년 4월 30일까지 재배하였다. 온실내부 야간 설정온도는 15℃를 유지하였으며 주간에는 23∽24℃를 유지할 수 있도록 측창 및 천창을 개방하였다. PO필름의 단동 및 연동온실 내부에서의 일사량, 온습도 등을 측정하였고, 재배 기간 동안의 생육량을 조사하였으며 에너지 절감 효과를 조사 하기 위해 피복재별 시험온실의 온풍난방기 연료 소비량을 조사하였다. 조사 결과 단동온실에서의 일사량은 PO필름 온실 에서 PE필름 온실보다 7% 증가하였고 수확량은 20% 증대되었다. 연동온실에서의 일사량은 PO필름 온실에서 PE필름 온 실보다 11% 증가되었고, 수확량은 9% 증가하였다. 또한 온실내부의 일평균 온습도 측정 결과 단동온실은 PE, PO필름 온실이 19.0℃, 19.1℃, 상대습도 75%를 나타냈고 연동온실 은 PO필름 온실이 19.6℃, 상대습도 57%를 나타냈고 PE필 름 온실이 18.8℃, 상대습도 63%를 나타냈다. 연료 소비량은 단동온실의 PO필름 온실이 PE필름 온실보다 12.4% 절감되 었고 연동온실에서는 PO필름 온실이 PE필름 온실보다 11.5% 절감된 것으로 나타났다.
        4,300원
        8.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to provide a basis for raising farm income by increasing the yield and extending the cultivation period by creating an environment where crops can be cultivated normally during high temperatures in summer. The maximum cooling load of the multi-span greenhouse with a floor area of 504 m2 was found to be 462,609 W, and keeping the greenhouse under 32°C without shading the greenhouse at a high temperature, it was necessary to fog spray 471.6 L of water per hour. The automatic fog cooling control device was developed to effectively control the fog device, the flow fan, and the light blocking device constituting the fog cooling system. The fog cooling system showed that the temperature of the greenhouse could be lowered by 6°C than the outside temperature. The relative humidity of the fog-cooled greenhouse was 40-80% during the day, about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The relative humidity of the fog cooling greenhouse during the day was 40-80%, which was about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The yield of cucumbers in the fog-cooled greenhouse was 1.8 times higher in the single-span greenhouse and two times higher in the multi-span greenhouse compared to the control greenhouse.
        4,300원
        9.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관 (백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 20~23oC, 관부 온도를 13~15oC로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 20~23oC의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함 으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 4oC + 관부난방(처 리 1), 공간 난방 8oC (대조구), 공간 난방 6oC + 관부 난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 8oC(대조구)의 경우 1,320L (100%), 공간난방 4oC + 관부난방의 경우 928L(70.3%), 공간난방 6oC + 관부난방의 경우 1,161L (88%)로 계측 되었다. 공간난방 4oC + 관부난방(처리 1) 및 공간난방 6oC + 관부난방(처리 2)은 8oC 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.
        4,000원
        10.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry ‘Seolhyang’ using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at 18 ~ 22oC. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above 30oC. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone 20oC+inside greenhouse 5oC) and crown local heating(crown 20oC+inside greenhouse 5oC) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse 9oC). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.
        4,000원
        11.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature 60℃, the heat flux of multi-later insulating curtain is T Co.(73.1W/m2) > S Co.(119.5W/m2) > U Co.(155W/m2) > N Co.(163.1 W/m2) > P Co.(177.7W/m2). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.
        4,000원
        12.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 방울토마토 재배 단동온실에 공기순환팬을 설치하고 공기순환팬이 온실 내 온도 및 습도 분포, 에너지소비량에 미치는 영향을 분석하였다. 공기순환팬은 날개 크기 230mm의 Stainless 팬으로, Lee 등(2016)의 연구결과를 참고하여 시험구 온실에 9m 간격으로 총 18 대를 설치하였다. 온실 내부 온습도는 온실 길이방향으 로 4등분하여 1/4 지점과 3/4 지점의 중앙에 센서를 설치하고 0.8m, 1.8m 높이 2곳의 온습도를 난방을 주로 하는 야간(오후 6시~다음 날 오전 7시)에 5분 간격으로 측정하였다. 에너지소비량은 각 온실에 위치한 온수펌프의 유량, 온수 출수부와 환수부의 온도차를 측정하여 계산하였다. 공기순환팬을 사용하지 않았을 때 측점 간 온도차 및 습도차의 평균값은 0.75oC, 2.19%였으며 공기 순환팬 사용 시 측점 간 온도차 및 습도차의 평균값은 0.42oC, 1.27%로 감소하였다. 공기순환팬 설치 온실과 미설치 온실의 누적 에너지소비량은 각각 4,673kWh, 4,009kWh로 공기순환팬 설치 온실에서 약 14.2%의 에너지를 적게 소모하였다. 이러한 결과로 보아 온실 내 공기순환팬 사용은 공기를 지속적으로 교반시켜 주어 온실 전체의 온도 및 습도를 균일하게 만들고, 공기의 온도가 빠르게 변하지 않도록 해주어 난방 장치의 가동 시간과 에너지소비량을 줄일 수 있다.
        4,000원
        13.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a hot water pipe and a blowing fan were combined for developing zone heating technology for cherry tomato. The concept of this system was that hot air was firstly made by hot water pipe in one layer plastic duct and then a blowing fan made the hot air formed in a duct discharge through a duct hole to a shoot apex or a flower cluster which was temperature-sensitive part of cherry tomato. This system mainly consisted of hot water boiler, thermal tank, heat radiation plastic duct with the function of moving up and down electrically depending on the height of shoot apex. Developed system was applied to the cherry tomato greenhouse located in Jangam Chungcheongnamdo from Dec. 28, 2015 to Feb. 16, 2016 and compared with conventional entire space heating system of cherry tomato greenhouse and looked into cumulative yield for the estimate of growing state and energy saving rate from the conventional consumed energy. The result showed that cumulative yield was 3% higher and consumed energy was 32% lower than those of control greenhouse. The average temperature of shoot apex zone was 0.4~1.1℃ higher and the average relative humidity of shoot apex zone was 2,2~2.3% lower than those of entire space during night time in a shoot apex zone heating greenhouse and the average temperature of shoot apex zone was 0.7~1.4℃ lower and the relative humidity of shoot apex zone was 2.9~8.3% higher than those of entire space during night time in a entire space heating greenhouse.
        4,000원
        14.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 폭 7m, 길이 25m, 동고 3.2m의 토마토를 재배하는 온실에 공기순환팬을 설치하고 순환팬이 온실 내 온도 및 습도 분포에 미치는 영향을 조사하였다. 기존의 순환팬 설치 기준(ASAE, 1997)을 참고하여 시험 온실에 순환팬 10대를 2열 및 다른 방향으로 설치하여 18시부터 다음날 8시까지 온실 내 온습도를 측정하였다. 온실 내 온습도는 온실을 9개의 격자망으로 나눈 후 온실 중앙부에서는 0.7m, 1.7m 및 2.7m 높이, 온실 좌우 측에는 0.7m, 1.7m 높이에 센서를 설치하였다. 공기순환 팬을 사용하지 않았을 때 온실 상하부의 온도 및 습도의 평균값은 14.7oC, 74.8%와 13.0oC, 85.6%로 온습도 차는 평균적으로 1.7oC, 10.8% 발생하였다. 공기순환팬 10대를 2열 및 다른 방향으로 설치하여 운용했을 때 온실 상하부의 온습도는 14.6oC, 75.9%와 14.5oC, 79.1% 로 온습도 차는 각각 0.1oC, 3.2%였으며 순환팬을 사용 하지 않았을 때와 비교하여 온실 상하부의 온도 및 습도 차가 감소하였다. 순환팬을 6대 및 5대로 줄여서 운용했을 때 온실 상하부의 온습도 차는 각각 0.3oC, 3.4%와 0.3oC, 4.0%로 나타나 순환팬 10대를 사용했을 때와 비슷한 효과를 보였다. 순환팬 10대를 2열 및 같은 방향으로 설치했을 때의 온실 상하부의 온습도 차는 0.5oC, 4.9%로 팬을 다른 방향으로 설치했을 때보다 온습도 차가 크게 나타났다. 온실 좌우측면, 전후면의 온습도 차를 살펴보면 순환팬을 사용하지 않았을 때 좌우 측면의 온습도 차는 0.3oC, 1.7%로 작아 팬을 사용했을 때와 큰 차이가 없었으나 순환팬을 사용하지 않았을 때 1.0oC, 4.2%로 나타났던 전후면의 온습도 차는 순환팬을 사용함으로써 감소하였다. 이는 공기순환팬이 온실 내 공기를 순환시켜 온풍난방 시 상부에 정체된 더운 공기나 열손실로 인해 온도가 다른 공기를 교반시킴으로써 온도 및 습도 차가 감소한 것이다. 폭 7m, 길이 25m, 동고 3.2m인 단동온실에서 날개 크기 230mm, 풍량 11m3/min의 공기순환팬을 사용하고자 할 때는 순환팬 5대를 2열로 설치하되 각 열을 방향을 다르게 하고 9m 간격으로 설치하여 운용하는 것이 가장 경제적이고 효과적일 것이다.
        4,000원
        15.
        2016.10 구독 인증기관 무료, 개인회원 유료
        Results of this study appeared chicken breeding households nationwide in 3,323 households. Local broiler breeding two numbers are Jeonbuk>Chungnam>Jeonnam> Gyeonggi>Gyeongbuk>Chungbuk>Gyeongnam>Gangwon>Jeju appeared in other net. Local chicken breeding numbers are Chungnam>Jeonbuk>Gyeongbuk>Jeonam> Chungbuk>Gyeongnam>Gangwon appeared in order. Livestock mortality is 482,000 numbers in 2012, and 911,000 numbers in 2014 and 2.494,000 numbers in 2015, a significant increase year by to 4.298,000 numbers in 2016. Insurance 11.2 billion in 2012, 49.8 billion in 2013, 21.2 billion in 2014, 74.5 million won was paid in 2015 is expected to be paid in 2016, 128.4 billion won. A study on the future, preventing livestock damage caused by high temperature will have to continue.
        4,000원
        16.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, environmental new feeding and management system that are suitable for hot and cool water supply and floor heating system was developed and analyzed the effect for productivity and meat quality with supplying hot water in winter, the results were as follow as. HWSS was not affecting improvement with broiler productivity in initial time. Supplying hot water made the temperature inside broiler barn not go down rapidly as time went by from former term to latter term and continuous supplying hot water made boiler be adapted properly to the temperature and humidity of breeding environment that was requiring at its own growth phases. With unsaturated fatty acid / saturated fatty acids, HWSS was higher in broiler breast but CWSS was higher in the leg. With AST, ALT in blood, HWSS is higher than CWSS but with neutral lipid, protein, glucose, albumin, cholesterol, HWSS is higher than CWSS. Water circulation heating system gave an impact on meat quality and PH showed a higher in CWSS system. Also, redness and yellowness of the meat color was confirmed to be greater in HWSS. It was proved that the temperature difference of drinking water affected farm productivity, the blood and flesh quality, therefore, that could be estimated to be utilized successfully, if that should be used appropriately for productivity improvement according to the week-old of growth phase.
        4,000원
        17.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of these studies are to provide a basic data for the development of high-efficiency environmental improvement system that can parallel the cage(henhouse) and hot and cold potable water supply for increased summer heat stress relief and winter feed efficiency by optimal design. The cage area is 273m2. The air-to-water heat pump with 20RT capacity was used for heating and cooling. The control was used as an electric hot water boiler. For calculating heating load determined the cage size, materials, heat pump capacity, heating capacity, heat storage tank, and drinking water tank capacity etc. Therefore the capacity of heat pump was set-up using 20RT. The cage was built as a prefabricated panels henhouse of 13×21×4.5 m (width×depth×height). The heat storage tank and was drinking water tank capacity was constructed 3tons and 10 tons, respectively. In future, it is thought that optimal design considering the cage size and hen breeding scale is required.
        4,000원
        18.
        2015.11 구독 인증기관 무료, 개인회원 유료
        In this study, to develop high-efficiency environmental improvement system that can be combined with hot and cold potable water supply to poultry air conditioning for the summer increase heat stress relief and winter feed efficiency through optimal design hwihan The aim of this study was to provide basic data. As a cage the size of the system installed is 100m2 test capacity 20RT district heating and cooling of air-to-water heat pump and the control was composed of electric hot water boilers. First of cage sizes for heating load design, materials, heat pump capacity, air capacity, storage tank, drinking water tank capacity, etc. were determined. The capacity of the heat pump was set to 20RT cage captive birds are erected as vertically and horizontally × height × (13 × 21 × 4.5m). Storage tank 3 tons and capacity of 10 tons potable water tank was designed. In the future, the size of the cage, designed according to the best breeding two numbers are needed.
        4,000원
        19.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 동절기 시설원예 난방에너지 절감을 위해 방울토마토의 온도민감부인 생장부를 추종하면서 난방을 수행할 수 있는 국소난방 시스템을 개발하고자 하였다. 방울토마토 생장부 추종형 국소난방시스템은 온실 하류로의 균일한 열분배를 위해 내/외부 덕트와 온풍난 방기를 연결하는 이중덕트 분배장치, 정식 후 작물 유인에 따라 덕트를 토마토 줄기끝 생장점과 개화화방을 추종하여 상하로 이동시키기 위한 권취장치 등으로 구성되었다. 국소난방 시스템의 운용은 토마토 정식 직후에는 덕트를 작물 상부에 위치시키며 작물 생장에 따라 생장부 국소난방과 차광 회피를 위해 덕트를 상하로 이동시켰다. 방울토마토 수경재배 온실을 대상으로 생장부 국소난 방구와 관행의 바닥덕트 난방구에 대해 난방성능과 작물 생육 비교시험을 수행하였다. 그 결과 생장부 국소난방구는 야간 난방시간에 작물 군락내 상부 기온이 하부에 비해 0.9~2.0oC 높으며, 바닥덕트 난방구에 비해 군락 상부 기온은 0.3~1.8oC 높고, 하부 기온은 1.4~1.8oC 낮게 나타나 온도에 민감한 상부 생장부를 상대적 고온으로 관리하고, 군락하부는 상대적 저온으로 관리 가능하며, 관행 바닥덕트 난방구의 높이별 온도분포를 역전시킬 수 있음을 확인하였다. 토마토 군락에 대한 적외선 열화상 측정을 통해 정식 직후부터 줄기내림 유인재배 기간에 걸쳐 생장부 국소난방구는 군락내에 높이별 엽온의 온도성층화를 형성하여 생장부 추종 국소난방이 가능 함을 확인하였다. 난방방식별 작물생육 분석결과 초장을 제외한 나머지 항목은 유의적인 차이가 없었으며, 수확량에서도 생장부 국소난방구가 초기 수량이 약간 우세하였으나 총 수확량은 동일한 수준으로 나타났다. 온풍난 방비 경유소비량은 생장부 국소난방구가 군락의 높이별 최적 온도관리로 관행 바닥덕트 난방구에 비해 약 23.7% 절감되는 것으로 나타났다. 본 시스템은 길이 90m 온실에 대한 적용시험에서 열 분배 성능의 한계로 온실 상/하류간 온도편차가 발생하였으며, 시스템 개선을 위해 내부덕트의 직경 또는 두께 상향, 열복사 억제 재질의 덕트 사용 등 열분배 성능 최적화를 위한 추가연구가 필요한 것으로 판단되었다.
        4,000원
        20.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 온실 내부의 태양 잉여열과 외부의 공기열을 선택적으로 열원으로 이용함으로써 히트펌프의 성능을 향상시키고, 온실의 환기 지연을 통해 이산화탄소 시용비용을 절감할 수 있는 온실 공조시스템을 개발 하고자 하였다. 본 시스템의 축열 과정은 태양 잉여열을 이용하는 내부순환모드와 외기열을 이용하는 외부순환모드가 온실 내부온도에 따라 자동으로 절환되도록 구성하였으며, 히트펌프가동, 축열모드 절환, 난방 가동을 위한 6개의 온도값을 입력함으로써 축열과 난방이 자동으로 수행되도록 설계하였다. 단동온실을 대상으로 무환기 조건에서 기초시험을 수행한 결과, 태양 잉여열을 이용한 축열은 약 11시부터 시작되어 평균 3시간 30분 정도 유지되었으며, 주간의 온실 내부온도는 환기를 수행하지 않음에도 대부분 약 20~28oC 범위를 유지하였다. 주간 내부순환모드에서 시스템의 난방성능계수는 약 3.35로 야간 외부순환모드의 2.46 및 주간 외부순환모드의 2.67 에 비해 각각 36% 및 25% 향상됨을 확인하였다. 본 시스템의 개선사항으로 태양 잉여열의 효율적 이용을 위해 축열조 관리온도를 상승시킬 수 있는 고효율 히트펌프의 적용이 필요하며, 온실의 무환기 운용에 따른 과습환경의 조성을 방지하고 태양 잉여열 수준이 높은 시기에 온실의 온도상승을 방지하기 위해 강제환기를 운전모드에 추가할 필요가 있는 것으로 판단되었다.
        4,000원
        1 2