검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2008.09 구독 인증기관 무료, 개인회원 유료
        A bi-axial tuned liquid mass damper(TLMD) was proposed and evaluated on its control performance. The proposed TLMD controls structural response in a specific one direction by using the liquid sloshing of TLCD. Also, the TLMD controls structural response in the other orthogonal direction by TMD behavior which mass consists of the container itself and liquid within container of TLCD installed on linear motion guides. Force-vibration tests on a real-sized structure with the TLMD were performed to verify its independent behavior in two orthogonal directions. Test results showed that the responses of a structure were considerably reduced by using the proposed TLMD and its usefulness for structural control in two orthogonal directions.
        4,000원
        2.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하나의 제어장치로 서로 직교하는 2방향의 건물응답을 동시에 제어할 수 있는 동조액체질량감쇠기(Tuned Liquid Mass Damper; TLMD)를 제안하고 제어성능을 실험적으로 검증하였다. 본 연구에서 제안된 TLMD는 한 방향으로는 동조액체기둥감쇠기(Tuned Liquid Column Damper; TLCD) 내부에 채워진 액체의 운동에너지를 이용하여 구조물의 응답을 제어하게 된다. 그리고, 다른 한 방향 즉 TLCD의 직각 방향으로는 LM guide(linear motion guide) 위에 놓인 TLCD 수조와 내부의 액체의 질량을 이용하여 동조질량감쇠기(Tuned Mass Damper; TMD)로 거동하게 함으로써 구조물의 응답을 감소시킨다. 이와 같은 TLMD의 양방향 독립거동 특성을 증명하기 위해 실물크기의 구조물에 설치하여 강제진동실험을 수행하였다. 실험결과, 양방향 모두 대상 구조물의 응답을 감소시키는 것을 확인하여 제안된 TLMD의 효용성을 검증하였다.
        4,000원
        3.
        2007.03 구독 인증기관 무료, 개인회원 유료
        Forced vibration testing is important for correlating the mathematical model of a structure with the realone and for evaluating the performance of the real structure. There exist various techniques available for evaluating the seismic performance using dynamic and static measurements. In this paper, full scale forced vibration tests simulating earthquake response are implemented by using a hybrid mass damper. The finite element(FE) model of the structure was analytically constructed using ANSYS and the model was updated using the results experimentally measured by the forced vibration test. System identification of real-scaled 5 story building structure which is located in UNISON INC. is conducted on the updated FE model.
        4,000원
        4.
        2006.09 구독 인증기관 무료, 개인회원 유료
        This paper presents vibration control of a real-scaled five-story steel structure subjected to horizontal excitation using a semi-active magneto-rheological (MR) damper. A large-sized double-rod MR damper, which is applicable for vibration control of the real-scaled five-story structure, is designed and manufactured on the basis of the field-dependent Bingham model of the MR fluid. The damping force of the MR damper is experimentally evaluated with respect to the excitation frequency at various magnetic fields. After formulating the governing equation of motion for the five-story structure associated with the MR damper, displacement and acceleration responses of the structure are discussed under pseudo earthquake excitation in which a hybrid mass damper is designed to reproduce seismically excited structural responses. The controllers which require only structural response of the damper installed floor for calculating the input current of the MR damper are designed to effectively suppress unwanted structural vibrations
        3,000원