검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2023.11 구독 인증기관·개인회원 무료
        Korea Hydro & Nuclear Power (KHNP) is currently developing a vertical concrete dry storage module for the dry storage of used nuclear fuel within nuclear power plants. This module is designed with a structure consisting of cylinders, which can block the ingress of external air, thereby preventing Chloride-Induced Stress Corrosion Cracking (CISCC). However, due to the presence of these cylinder structures, unlike conventional dry storage systems, it cannot directly dissipate heat to the external atmosphere, making thermal evaluation an important issue. The SF dry storage module being developed by KHNP is a massive concrete structure of approximately 20 m × 10 m × 7 m in size, employing a vertical storage system. To demonstrate the safety of such a large structure, there is no alternative to conducting experiments with scaled-down models. Furthermore, according to NUREG-2215 Section 5.5.4, it is explicitly mentioned that design-verification testing can be performed using scaled-down models. In this paper, a 1/4 scaled-down model was constructed to perform thermal performance verification experiments, and the effectiveness of this model was analyzed using Computational Fluid Dynamics (CFD) methods. The analysis results indicated that there was not a significant difference in terms of maximum concrete temperature and air outlet temperature. However, a considerable difference was observed in the canister surface temperature. Therefore, it is concluded that careful consideration of natural convection heat transfer is necessary for the full application of the scaled-down model.
        2.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        프리캐스트 코핑의 중공부 주철근 단절로 인한 단점을 보완하고, 거치대 삽입 없이 주철근을 거치대로 활용할 수 있 도록 철근-콘크리트 접촉부의 응력집중을 완화할 수 있는 하중분산세트의 성능을 검토하였다. 유한요소해석 및 축소모형실험을 통해 검토한 결과 하중분산세트는 철근-콘크리트 접촉부의 응력집중을 효과적으로 완화시켜 거치 시 콘크리트 파손을 방지할 수 있을 것으로 판단된다.
        4,000원
        6.
        2018.05 구독 인증기관·개인회원 무료
        The purpose of this study was to investigate the feasibility of converting the results obtained using different rutting performance tests. The correlation between the three simulation tests was analysed to determine the conversion coefficient factor. Two parameters (temperature and speed of simulation testing) were evaluated in this study. The results of this study have shown that the values obtained in the SALS test were lower than those obtained in the HWTT and UKWTT. The conversion of the SALS test results to the HWTT results yielded a good propensity value. The temperature is important parameter for determining the conversion coefficient factor.
        7.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Large spatial structures can not easily predict the dynamic behavior due to the lack of construction and design practices. The spatial structures are generally analyzed through the numerical simulation and experimental test in order to investigate the seismic response of large spatial structures. In the case of analysis for seismic response of large spatial structure, the many studies by the numerical analysis was carried out, researches by the shaking table test are very rare. In this study, a shaking table test of a small-scale arch structure was conducted and the dynamic characteristics of arch structure are analyzed. And the dynamic characteristics of arch structures are investigated according to the various column cross-section and length. It is found that the natural vibration periods of the small-scaled arch structure that have large column stiffness are very similar to the natural vibration period of the non-column arch structure. And in case of arch structure with large column stiffness, primary natural frequency period by numerical analysis is very similar to the primary natural frequency period of by shaking table test. These are because the dynamic characteristics of the roof structure are affected by the column stiffness of the spatial structure.
        4,000원
        8.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하나의 제어장치로 서로 직교하는 2방향의 건물응답을 동시에 제어할 수 있는 동조액체질량감쇠기(Tuned Liquid Mass Damper; TLMD)를 제안하고 제어성능을 실험적으로 검증하였다. 본 연구에서 제안된 TLMD는 한 방향으로는 동조액체기둥감쇠기(Tuned Liquid Column Damper; TLCD) 내부에 채워진 액체의 운동에너지를 이용하여 구조물의 응답을 제어하게 된다. 그리고, 다른 한 방향 즉 TLCD의 직각 방향으로는 LM guide(linear motion guide) 위에 놓인 TLCD 수조와 내부의 액체의 질량을 이용하여 동조질량감쇠기(Tuned Mass Damper; TMD)로 거동하게 함으로써 구조물의 응답을 감소시킨다. 이와 같은 TLMD의 양방향 독립거동 특성을 증명하기 위해 실물크기의 구조물에 설치하여 강제진동실험을 수행하였다. 실험결과, 양방향 모두 대상 구조물의 응답을 감소시키는 것을 확인하여 제안된 TLMD의 효용성을 검증하였다.
        4,000원
        9.
        2007.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 풍하중에 대한 기존 송전철탑의 좌굴 및 구조적 안전성을 평가하기 위해서 축소부분구조 실험을 수행하였다. 원 송전철탑에 작용하는 중력 및 풍하중을 재현하기 위해서 1/2크기의 상사법칙을 적용한 축소모델의 상부에 설치된 삼각형태의 지그를 이용하여 가력하는 방법을 고안하였다. 설계하중에 대한 실험체의 안정성을 평가하기 위해서 예비수치 해석을 수행한 결과, 계산된 주주재의 축력은 허용좌굴하중의 사이에 분포하고 있음을 확인하였다. 최대허용좌굴 하중의 270%까지 가력한 결과, 주주재의 면외거동을 구속하는데 취약한 절점에서 발생한 국부좌굴로 인하여 송전철탑이 파괴되었다. 하중-변위 곡선, 변위, 부재별 변형률을 검토한 결과, 이러한 국부좌굴의 발생은 동일한 단면내에서도 휨모멘트로 인해 항복응력에 도달하는 시간이 위치별로 다르기 때문에 변형의 불균형에 의해서 발생한 부가적인 편심에 기인한 것으로 판단된다.
        4,300원