검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,280

        86.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When the center of stiffness and the center of mass of the structure differ under the seismic load, torsion is caused by eccentricity. In this study, an analysis model was modeled in which the positions of the core and the plane rotation axis of a 60-story torsional atypical structure with a plane rotation angle of 1 degree per floor were different. The structural behavior of the analysis model was analyzed, and the earthquake response behavior of the structure was analyzed based on the time history analysis results. As a result, as the eccentricity of the structure increased, the eccentricity response was amplified in the high-rise part, and the bending and torsional behavior responses were complex in the low-order vibration mode. As a result of the analysis, the maximum displacement and story drift ratio increased due to the torsional behavior. The maximum story shear force and the story absolute maximum acceleration showed similarities for each analysis model according to the shape of the vibration mode of the analysis model.
        4,000원
        87.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.
        4,000원
        88.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 비구조요소의 피해사례가 증가하면서 비구조요소 내진설계에 관한 많은 연구가 진행되고 있다. 하지만 대부분의 연구는 평면 적 요소보다는 수직적 요소나 시스템적 요소를 변수로 층가속도를 평가하고 있다. 때문에 본 논문에서는 횡력저항에 많은 부분을 차 지하는 코어를 평면적 변수로 사용하여 비구조요소 내진설계를 위한 층가속도에 대해 평가하였다. 정사각형의 2축대칭의 평면에서 코어의 형태(위치 및 비중)변화에 따라 서로 다른 5개의 평면과 각 평면마다 5층, 10층, 15층, 20층의 층수를 가진 총 20개의 모델로 선 형시간이력해석을 수행하였다. 분석 결과 코어 위치에 따라 편심을 받는 평면에서는 층가속도가 최대 1.7배의 비틀림 증폭이 발생하 였고 구조물의 중층부에서 비틀림의 영향이 가장 큰 것을 확인할 수 있었다. 편심이 없이 코어의 비중만 변화한 평면에서는 주기 0.4694초를 기준으로 이하일 때는 주기가 증가할수록 층가속도가 저층부에서는 감소하고 고층부에는 증가하며, 반대로 주기 0.4694 초 이상일 때는 주기가 증가할수록 층가속도가 저층부에서는 증가하고 고층부에는 감소한다는 것을 확인할 수 있었다. 또한, 구조물 의 층수는 최대층가속도에 영향을 주지 못하는 것을 확인하였다. 핵심용어 :
        4,000원
        89.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems’ joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.
        4,200원
        90.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.
        4,200원
        91.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The 2017 Pohang earthquake caused severe damage to low-rise piloti buildings. The damage was caused mainly by column shear failure, and some core walls were as well. The damaged piloti buildings in Pohang City could be relieved if they were designed correctly according to the standards at that time. However, the post-earthquake investigation revealed design, construction, and permission problems. To solve the problems, the Piloti Building Structure Design Guidelines that include strict specifications were published in 2018. Separately, KDS 41 17 00, the seismic design standard for buildings, was enacted in 2019 and it included the guideline contents. Therefore, at least after the publication of the guidelines, piloti buildings, designed by the standard and guidelines, can be expected to possess better seismic performance than existing piloti buildings. To confirm this, the probability of exceedance for several damage state thresholds was estimated for existing and designed piloti buildings. As a result, the probability of damage of designed piloti buildings was very low compared to existing ones. Consequently, it was confirmed that the guideline and standard adequately supplement the structural fragility of existing piloti buildings.
        4,000원
        92.
        2022.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in “Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed.” The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.
        4,000원
        93.
        2022.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic performance of a two-story unreinforced masonry (URM) building was assessed following the linear and nonlinear static procedures specified in the seismic evaluation guideline of existing buildings. First, the provisions to assess failure modes and shear strengths of URM walls and wall piers were reviewed. Then, a two-story URM building was assessed by the linear static procedure using m-factors. The results showed that the walls and wall piers with aspect ratios he /l (i.e., effective height-to-length ratio) > 1.5 were unsafe due to rocking or toe crushing, whereas the walls with he /l ≤1.5 and governed by bed-joint sliding mainly were safe. Axial stresses and shear forces acted upon individual masonry walls, and wall piers differed depending on whether the openings were modeled. The masonry building was reevaluated according to the nonlinear static procedure for a more refined assessment. Based on the linear and nonlinear assessment results, considerations of seismic evaluation for low-rise masonry buildings were given with a focus on the effects of openings.
        4,200원
        94.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        강진 시 원자력발전시설의 비선형 응답이 중요하기 때문에 이 시설의 내진성능에 대한 관심이 증가하였다. 이 연구에서는 원자력 발전소 철근콘크리트 전단벽의 유한요소해석을 위한 재료모델의 적절한 변수를 제시하였다: 최대인장강도, 팽창각, 손상계수. 이를 위해 상용 유한요소 해석프로그램인 ABAQUS를 사용하여 낮은 형상비를 가진 철근콘크리트 전단벽의 비선형 거동과 전단 파괴모드 에 대한 이 주요 변수의 효과에 대한 연구를 수행하였다. 연구결과에 기반하여 비선형 시간이력해석을 통해 강진 하의 원자로건물의 비선형 응답을 평가하였다.
        4,000원
        95.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        배전기 캐비닛은 발전소와 같은 플랜트 시설에서 전자기기 혹은 시스템 컨트롤러 등을 보관하는 역할을 한다. 전기 캐비닛이 지진과 같은 외부하중에 의해 손상될 경우 시스템 장애 혹은 운영 중단이 발생할 수 있다. 안정적이고 지속가능한 에너지 공급을 위해 외부 하중에 의한 전기 캐비닛의 안전성 평가는 매우 중요하다. 전기 캐비닛은 주로 콘크리트 슬래브에 앵커 로 지지되기 때문에 앵커의 지지력 상실로 인해 전기 캐비닛이 손상될 수 있다. 콘크리트 재료는 다양한 불확실성이 존재하며 변동성이 다른 재료에 비해 큰 편이다. 따라서 본 연구에서는 선행연구에서 개발된 전기 캐비닛-앵커 시스템의 유한요소 모델을 이용하여 콘크리트 재료의 불확실성을 고려한 지진 취약도 평가를 수행하였다. 30개의 콘크리트 재료 모델을 라틴 하이퍼큐브 샘플링을 이용하여 샘플링하였으며 울진 지역의 등재해도 스펙트럼을 만족하는 인공지진을 적용하여 시간이력 해석을 수행하였다. 앵커의 응력과 캐비닛 최상단의 변위를 한계상태로 정의하였다. 지진 취약도 분석 결과 0.2g를 초과할 때 앵커의 응력 및 캐비닛 최상단 변위가 정해진 한계상태를 초과하는 것으로 나타났으며 대부분 0.5g에서 파괴되는 것으로 나타났다. 추후 연구에서는 지진의 불확실성과 재료의 불확실성을 동시에 고려하여 지진 취약도 평가를 수행하고자 한다.
        4,000원
        96.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The precast-buckling restrained braces(PC-BRB) reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. In this study, to examine the applicability of PC-BRB to actual structures, example structures similar to school facilities were selected and the reinforcement effect was analyzed analytically according to the damping design procedure of PC-BRB. Load-displacement curve through the incremental loading test appeared similar to the bilinear curve. Applying test result, Analytical model of PC-BRB model was constructed and applied to the example structure. As a result of the analysis, the PC-BRB showed stable hysteresis behavior without lowering the strength, and the inter story drift ratio and the shear force were reduced due to the damping effect. In addition, the reduction ratio of the shear force was similar to the reduction ratio assumed when designing the damping device.
        4,000원
        97.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a twisted shape structure with an elevation form favorable to the resistance of vibration caused by wind loads is selected from among the forms of high-rise buildings. The analytical model is a square, triangular, and hexagonal plane with a plane rotation angle of one degree from 0 to 3 degrees per each story. As a result of the analysis, as the twist angle increased, story drift ratio is increased. Responses with different eccentricity rates were shown by analytical models. Therefore planar shapes designed symmetrically to the horizontal axis of X and Y are considered advantageous for eccentricity and torsion deformation. In the case of the bending moment of the column, the response was amplified in the column supporting the base floor, the roof floor, the floor in which the cross-section of the vertical member changes, and the floor having the same number of nodes as the base floor. Finally, the axial force response of the column is determined to be absolutely affected by the gravity load compared to the lateral load.
        4,000원
        99.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        후쿠시마 원전사고 발생으로 다수기의 지진안전성에 관한 연구의 필요성이 부각되었다. 한 부지에 건설된 원자력발전소의 경우 유 사한 지진응답을 보이기 때문에 적게나마 원자력발전소 SSCs간의 지진손상에 대하여 상관성이 존재하므로 합리적 지진안전성 평가 를 위하여 지진손상 상관성을 고려하여야 한다. 본 연구에서는 쌍둥이 호기의 필수전원상실사건에 대하여 확률론적 지진안전성 평가 를 수행하였다. 적절한 지진손상 상관계수를 도출하기 위하여 확률론적 지진응답해석을 수행하여 적용하였다. External Event Mensuration System 프로그램을 활용하여 다수기의 필수전원상실사건의 고장수목을 구성하여 지진취약도 및 지진리스크를 분석하 였다. 또한 SSCs간의 지진손상 상관성을 완전독립 및 완전종속으로 고려하여 비교 분석을 수행하였다.
        4,000원
        100.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문에서는 박스형 전력구의 지진응답해석에 사용되는 응답진도법의 보수성을 평가하였다. 이를 위해 25가지 전력구 단면과 각 전력구에 대한 2개의 지반조건을 고려한 총 50개 예제를 선정하였다. 응답진도법의 보수성을 평가하기 위해 동적 지반-구조물 상호 작용을 고려한 정밀해석법에 의한 응답과 비교하였다. 비교결과, 정밀해석 응답에 대한 응답진도법에 의한 응답의 비로 정의한 응답 비의 평균이 1.0에 근접하며, 응답비의 표준편차도 5% 이내로 매우 작아서, 응답진도법에 의한 해석이 정밀해석법과 일관됨을 알 수 있었다. 마지막으로 응답진도법에 의한 응답에 하중계수 1.1을 적용하면 전력구의 보수적인 내진설계가 가능할 것으로 나타났다.
        4,000원
        1 2 3 4 5