검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13

        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, numerical analysis was performed for the purpose of analyzing the flow characteristics and performance according to the change in the inflow hydrogen temperature and differential pressure of the receptacle of the hydrogen charging system. The pressure distribution and turbulent kinetic energy in the filter area were analyzed by changing the outlet pressure condition under the inlet hydrogen temperature condition, and the flow velocity change at the outlet was compared and analyzed. As a result of the analysis, as the differential pressure decreased, the flow rate at the outlet of the receptacle decreased by up to about 70% at the 2.86 MPa condition compared to the 1.86 MPa condition, and the mass flow rate decreased by about 56.5% at the maximum. It was found that the standard CV performance was not satisfied when the differential pressure at the inlet and outlet was 1.12 MPa or less under the 363K temperature condition.
        4,000원
        2.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performancecentered design.
        4,000원
        5.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기후변화는 국내 해충상의 변화에 영향을 주는 주요 요인 가운데 하나로 알려지고 있다. 특히 지구 온난화 모델에 따라 남방계 곤충의 서식 지 확대가 예상되고 있다. 휴면 기작을 가지고 있지 않은 파밤나방(Spodoptera exigua)과 배추좀나방(Plutella xylostella)은 시설재배지를 중심으 로 국내에서 월동이 가능한 것으로 알려지고 있다. 그러나 두 해충은 계절적 발생 양상에서 뚜렷한 차이를 보여주었다. 배추좀나방은 이른 봄철과 가을기간에 발생하고 여름 기간 중에는 발생하지 않았다. 반면에 파밤나방은 늦은 봄철에 나타나기 시작해 가을까지 지속적으로 발생하였다. 본 연구는 이러한 두 남방계 곤충이 계절적 발생 차이를 보이는 것이 이들이 갖는 고온에 대한 감수성 차이에 기인한 것으로 가정하였다. 이 가설을 증명하기 두 곤충의 내열성을 비교 분석하였다. 동일한 열처리(42℃)에서 배추좀나방 유충은 40 분 노출에 100% 사망률을 보인 반면, 파밤나방 은 대부분의 유충이 80 분의 노출에서도 생존하였다. 이러한 내열성은 두 곤충 모두 이들의 발육시기에 따라 상이했다. 배추좀나방은 4령 유충과 성충이 가장 높은 내열성을 보인 반면, 파밤나방은 1령 유충에서 가장 높게 나타냈다. 두 곤충 모두는 37℃에서 30 분간 전 처리 후 고온에 노출시 키면 생존율이 뚜렷하게 증가했다. 이러한 내열성유기는 두 곤충 모두 혈림프의 글리세롤 함량 증가와 관련성을 보였다. 또한 파밤나방의 경우는 열충격단백질의 발현도 증가하였다. 따라서 이상의 결과는 여름기간 배추좀나방의 발생이 없는 것은 이 곤충의 고온에 대한 높은 감수성에 기인 된 것으로 보이고, 반면에 파밤나방은 비교적 높은 내열성을 보유하여 여름 기간에도 발생을 지속시킨 것으로 해석되었다.
        4,000원
        6.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed
        4,200원
        7.
        2014.04 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        A novel method to characterize the topology of the early-universe intergalactic medium during the epoch of cosmic reionization is presented. The 21-cm radiation background from high redshift is analyzed through calculation of the 2-dimensional (2D) genus. The radiative transfer of hydrogen- ionizing photons and ionization-rate equations are calculated in a suite of numerical simulations under various input parameters. The 2D genus is calculated from the mock 21-cm images of high-redshift universe. We construct the 2D genus curve by varying the threshold differential brightness temperature, and compare this to the 2D genus curve of the underlying density field. We find that (1) the 2D genus curve reflects the evolutionary track of cosmic reionization and (2) the 2D genus curve can discriminate between certain reionization scenarios and thus indirectly probe the properties of radiation-sources. Choosing the right beam shape of a radio antenna is found crucial for this analysis. Square Kilometre Array (SKA) is found to be a suitable apparatus for this analysis in terms of sensitivity, even though some deterioration of the data for this purpose is unavoidable under the planned size of the antenna core.
        5,400원
        10.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온도 및 수분의 영향에 의하여 발생한 콘크리트 포장 슬래브의 컬링(curling)과 와핑(wraping)의 비틀림 거동은 자중이나 마찰력 등에 의하여 구속되며 이로 인하여 응력이 발생된다. 슬래브 내부의 온도 변화에 의해 발생한 응력은 상용 구조해석 프로그램으로 쉽게 계산할 수 있지만 습도 차이에 의하여 발생되는 응력은 기존 프로그램으로는 계산하기 어렵다. 따라서, 슬래브의 거동에 미친 습도의 영향이 등가의 온도로 환산되어 구조해석에 입력값으로 사용된다면 보다 정확하게 환경하중에 의한 슬래브의 거동을 예측할 수 있을 것이다. 본 연구에서는 콘크리트 슬래브를 현장에 시공하여 환경하중에 의해 발생된 변형률을 장기적으로 측정하였으며 실내에서 측정된 콘크리트 시편의 열팽창 계수를 사용하여 열변형률을 추출하였다. 나머지 변형률인 건조수축변형률을 추가적인 열변형률이라고 가정하고 이를 열팽창 계수로 나누어 줌으로써 건조수축과 등가의 영향을 갖는 가상의 온도가 계산되었다. 자중이나 마찰력 등이 고려되도록 기존 건조수축 모형을 수정하였으며, 이를 이용하여 슬래브 상부와 하부 상이에 발생한 건조수축의 차이를 등가의 온도차이로 환산할 수 있는 모형을 개발하였다. 보다 정확한 응력계산을 위하여 압축변형률의 지속적 증가에 따른 인장응력 감소에 관한 추가적인 연구가 이어질 것이다.
        4,000원
        12.
        1995.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 TiAl 금속간 화합물을 자전 고온 반응법을 이용하여 제조시 반응과정을 열시차 분석 방법으로 분석하였다. 합금 조성은 Ti-45at% Al, 53at%Al, 알루미늄 분말 크기, 승온 속도, 성형 밀도 등을 변화시켜 이들이 반응 과정에 미치는 영향을 관찰하였다. 분말이 미세할수록, 승온속도가 느릴수록, 성형 밀도가 낮을수록 반응 점화 온도 및 연소 온도가 감소하였으며, 고상 Ti와 고상 Al간의 반응정도가 증가하는 것이 관찰되었다. 고상 Ti와 고상 Al간의 반응에서 생성되는 것은 XRD 분석 결과 TiAl3상으로 확인되었다. 이에 비하여 반응 점화 온도가 알루미늄의 용융 온도보가 높을 경우에는 생성되는 상이 Ti3Al, TiAl상으로 확인되었다. 이러한 상의 생성 원인에 대하여 확산 계수 및 알루미늄의 용해도등의 요인으로 설명하였다.
        4,300원