This study aims to evaluate the relationship with the concentration and odor intensity using the odor sensory method for 4 types of sulfur compounds, ammonia, and trimethylamine. For the measurement, 13 panelists were selected by several criteria through a panel test. Panelists chosen for their closely similar sensitivities provide more reproducible values. The estimation showed that the correlation of the concentration with odor intensity for the 6 compounds can be reasonably expressed by the equation I=Aㆍlog C+B (I: Odor Intensity, C: material concentration, A: material constant, B: constant). The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration on site boundary in operation, as well as a correlation between the concentration and odor intensity for the designated foul odor substances, and their characteristics.