검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 51

        2.
        2023.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Infrared radiation (IR) refers to the region of the electromagnetic radiation spectrum where wavelengths range from about 700 nm to 1 mm. Any object with a temperature above absolute zero (0 K) radiates in the infrared region, and a material that transmits radiant energy in the range of 0.74 to 1.4 um is referred to as a near-infrared optical material. Germanatebased glass is attracting attention as a glass material for infrared optical lenses because of its simple manufacturing process. With the recent development of the glass molding press (GMP) process, thermal imaging cameras using oxide-based infrared lenses can be easily mass-produced, expanding their uses. To improve the mechanical and optical properties of commercial materials consisting of ternary systems, germanate-based heavy metal oxide glasses were prepared using a melt-cooling method. The fabricated samples were evaluated for thermal, structural, and optical properties using DSC, XRD, and XRF, respectively. To derive a composition with high glass stability for lens applications, ZnO and Sb2O3 were substituted at 0, 1, 2, 3, and 4 mol%. The glass with 1 mol% added Sb2O3 was confirmed to have the optimal conditions, with an optical transmittance of 80 % or more, a glass transition temperature of 660 °C, a refractive index of 1.810, and a Vickers hardness of 558. The possibility of its application as an alternative infrared lens material to existing commercial materials capable of GMP processing was confirmed.
        4,000원
        3.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this work, ultra-fine calcium oxide (CaO) powder derived from eggshells is used as the starting material to synthesize mineral trioxide aggregate (MTA). The prepared CaO powder is confirmed to have an average particle size of 500 nm. MTAs are synthesized with three types of fine CaO-based powders, namely, tricalcium silicate (C3S), dicalcium silicate (C2S), and tricalcium aluminate (C3A). The synthesis behavior of C3S, C2S and C3A with ultra-fine CaO powder and the effects of C3A content and curing time on the properties of MTA are investigated. The characteristics of the synthesized MTA powders are examined by X-ray diffraction (XRD), field emission-scanning electron microscope (FE-SEM), and a universal testing machine (UTM). The microstructure and compressive strength characteristics of the synthesized MTA powders are strongly dependent on the C3A wt.% and curing time. Furthermore, MTA with 5 wt.% C3A is found to increase the compressive strength and shorten the curing time.
        4,000원
        4.
        2016.11 구독 인증기관·개인회원 무료
        최근 셰일가스 산업의 호황과 더불어 셰일가스전에서 배출되는 폐수처리가 중요한 환경문제로 부각되고 있다. 셰일가스전 폐수는 총 용존고형물의 농도가 10에서 200g/L로 높기 때문에 역삼투 담수공정을 적용하기에 어려움이 있다. 본 연구에서는 셰일가스전 폐수를 처리하기 위해 저압에서 운전 가능한 정삼투 공정(FO)의 적용 가능성을 연구하였다. 특히 대표적으로 널리 활용되고 있는 유도용액인 NaCl과 NH3-CO2를 사용하여 셰일가스전 폐수에 포함되어 있는 2가 양이온이 FO공정에 미치는 영향을 알아보았다. FO공정 유도용액의 역확산은 막의 플럭스와 스케일로 인한 막오염에 중요한 영향을 끼치는 것으로 나타났다. 이를 통해 FO공정의 폐수 성상에 따라 유도용액 종류 선택 및 공정 디자인의 중요성이 입증되었다.
        5.
        2015.11 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Cu circuits were successfully fabricated on flexible PET(polyethylene terephthalate) substrates using wettability difference and electroless plating without an etching process. The wettability of Cu plating solution on PET was controlled by oxygen plasma treatment and SiOx-DLC(silicon oxide containing diamond like carbon) coating by HMDSO(hexamethyldisiloxane) plasma. With an increase of the height of the nanostructures on the PET surface with the oxygen plasma treatment time, the wettability difference between the hydrophilicity and hydrophobicity increased, which allowed the etchless formation of a Cu pattern with high peel strength by selective Cu plating. When the height of the nanostructure was more than 1400 nm (60 min oxygen plasma treatment), the reduction of the critical impalement pressure with the decreasing density of the nanostructure caused the precipitation of copper in the hydrophobic region.
        4,000원
        6.
        2015.05 구독 인증기관·개인회원 무료
        염도차가 있는 두 용액을 멤브레인을 통해 혼합시 염도차에너지를 생산할 수 있다. 특히, 삼투현상을 기본으로 하는 압력지연삼투(PRO) 공정을 사용하면 염도차에너지를 수력에너지로 변환할 수 있다. 이 압력지연삼투 기술의 핵심은 PRO 멤브레인으로, 이 멤브레인의 성능에 따라 생산되는 전력량이 결정된다. 본 연구에서는 개발중인 PRO 멤브레인 모듈의 성능인 물플럭스 기반의 전력밀도(W/m2)를 분석하여 평가를 수행하였다. PRO 멤브레인 모듈의 성능은 삼투압차가 클수록 커지지만, 삼투압차에 비례하지는 않았다. 이론적으로는 삼투압차의 절반 정도에서 최고의 전력밀도를 보이지만, 실제로는 멤브레인의 특성에 따라 최적 압력은 영향을 받는 것으로 보였다. 삼투압차와 압력차외에도 두 용액의 유량은 성능에 영향을 미쳤다.
        7.
        2015.05 구독 인증기관·개인회원 무료
        최근 셰일가스전 산업이 발전함에 따라 시추 용수 공급 및 폐수처리가 셰일가스전 개발의 중요한 과제로 부각되고 있다. 셰일가스전 폐수는 총용존고형물의 농도가 10에서 200g/L로 높아 기존의 폐수처리 공정으로 처리하기에는 어려움이 있다. 본 연구에서는 정삼투막을 이용하여 셰일가스전 폐수를 농축하는 공정을 다루고 있다. 260g/L의 NaCl을 유도용액으로 사용하고, 폐수 및 유도용액의 농도 변화에 따른 정삼투막의 플럭스를 측정하였다. 정삼투막 내,외부 농도 분극 현상을 감안한 모델식은 실측된 정삼투 플럭스와 유사함을 확인하였으며, 이를 바탕으로 정삼투 모듈의 성능을 예측하였다. 정삼투 공정은 유도용액을 희석시켜 시추 용수로 재이용하며, 발생폐수의 부피를 줄여 폐수 운반비용을 줄이는 효과를 얻을 수 있다.
        8.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to estimate odors emitted from toilets in Mugunghwa trains. Two parameters, odor intensity and odor concentration, were used for odor estimation. A direct olfactory method to observe odor intensity for 67 toilets and an air dilution olfactory method to estimate odor concentration for 6 samples were performed. Results showed that odor concentrations in toilets in trains ranged from 6 OU/m3 to 30 OU/m3, and odor intensity in 67 toilets varied from 0 degree to 3.3 degree. The results suggest that odors emitted from existing toilets should be controlled because the odor intensity in 16 toilets reached a level that resulted in complaints about the odor.
        4,000원
        9.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        황화수소 등 유황계 악취물질은 매우 낮은 최소감지농도를 갖고 있기 때문에 악취를 제거하기 위해서는 출구에서 악취가 검출되지 않는 적정 부하량에 대해 검토가 이루어져야 한다. 본 연구에서는 활성탄을 가공하여 제작한 습윤 상태의 활성탄소섬유를 이용하여 현장조건과 유사하게 황화합물악취 H2S 10 ppm, MT 3 ppm, DMS 1.5 ppm 3성분의 혼합가스에 대해 약 130일 동안 제거실험을 수행하였다. 그 결과, H2S는 유입부하량을 0.78 g-H2S / kg ACF·d 이하로 설정하여 운전하는 것이 필요하며, MT는 불완전산화 부산물인 DMDS가 출구에서 검출되어 악취를 유발하므로 안정적인 운전을 위해서는 유입부하량을 0.27 g-MT / kg ACF·d 이하로 설정하여 운전하는 것이 필요한 것으로 나타났다. DMS는 유입부하량의 변화에 관계없이 거의 제거되지 않는 것으로 나타났다.
        4,000원
        10.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The correlations among odor intensity, offensive substance concentration, and dilution factor were reviewed for the 12 designated offensive odor substances in this study. It is to propose new regulatory odor standards based on relationships between odor intensity and offensive substance concentration, as well as odor intensity and dilution factor at the site boundary which were obtained from the comprehensive reviews of the adequacy of current regulation standards. Changes in intensity were found to be necessary to reflect exponential changes in concentrations and dilution factors. The change of substance concentrations with respect to the dilution factor was found to be a relatively linear relationship. The thorough evaluations pf relationships among odor intensity, offensive substance concentration, and dilution factor led to the conclusion that the current regulatory standards were inadequate and the modification was necessary to reflect the new understandings. The new regulatory substance standards based on correlations with odor intensity for the 12 compounds were proposed. The proposed ammonia concentrations for the regulatory standard in the semi-industrial and industrial area were 15 ppm and 28 ppm, respectively. These are approximately 15 times higher than those of the current standards. For dimethyl sulfide, dimethyl disulfide, and isovaleraldehyde, the higher concentrations than those of current standards were also pro posed. The proposed regulatory standards of dilution factor in semi-industrial and industrial area were 25 and 50, respectively. It is found that proposed quantitative relationships among the odor intensity, the offensive substance concentration, and the dilution factor in this study turned out to be more adequate to Korean than the current ones.
        4,500원
        11.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the relationship with the concentration and odor intensity using the odor sensory method for 5 types of aldehyde compounds and styrene. For the measurement, 13 panelists were selected by several criteria through a panel test. The estimation showed that the correlation of the concentration with odor intensity for the 12 compounds including of the sulfur compounds, ammonia, and trimethylamine can be reasonably expressed by the equation I = Aㆍlog C + B (I : odor Intensity, C : material concentration, A : material constant, B : constant). The equations show the sensivities of intensity change for the change of concentration. According to the increase of concentration the odor intensities for acetaldehyde and iso-valeraldehyde increase larger than for the other aldehydes. Regulation standards of 12 species of odor substance concentraton and odor intensity by using the correlation equation was reviewed for adequacy. It was evaluated that the regulation standards on site boundary in operation are too low for NH₃, DMDS, and iso-valeraldehyde and too high for TMA. The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration on site boundary in operation.
        4,000원
        12.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the relationship with the concentration and odor intensity using the odor sensory method for 4 types of sulfur compounds, ammonia, and trimethylamine. For the measurement, 13 panelists were selected by several criteria through a panel test. Panelists chosen for their closely similar sensitivities provide more reproducible values. The estimation showed that the correlation of the concentration with odor intensity for the 6 compounds can be reasonably expressed by the equation I=Aㆍlog C+B (I: Odor Intensity, C: material concentration, A: material constant, B: constant). The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration on site boundary in operation, as well as a correlation between the concentration and odor intensity for the designated foul odor substances, and their characteristics.
        4,000원
        13.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The number of traffic accidents in 2010 was 226,978 in Korea, a high percentage of which up to 12.61% was due to drunk driving. As it is expected that the number of traffic accidents will increase because of the drastic increase of the number of vehicle registrations and the prevalent drinking cultures, it is necessary to understand the driving characteristics of drunken drivers to lower the increasing rate. METHODS: This study, therefore, comparatively analyzes the two groups - one group before drinking and the other after drinking - based on the graph, and implements the correlation in each scenario(1,2,3). scenario 1. appearance of jaywalkers; scenario 2. appearance of an illegal left-turning car; and scenario 3. appearance of a vehicle and a person as obstacles to the driver after an accident. RESULTS: The comparative analysis of speed shows that the group after drinking was 50km/h faster than the group before drinking in Scenario 1, 20km/h in Scenario 2, and 15km/h in Scenario 3 respectively. In the comparative analysis of acceleration, the average level of the group after drinking was 0.15 higher than that of the group before drinking in Scenario 1, 0.30 in Scenario 2, and 0.15 in Scenario 3. In the comparative analysis of deceleration, the average level of the group after drinking was about 0.4 lower than that of the group before drinking in Scenario 1, 0.35 in Scenario 2, and 0.2 in Scenario 3 respectively. In the comparative analyses, the item of speed, acceleration and deceleration was of significance for each group in Scenarios. CONCLUSIONS: The comparative analysis demonstrated that there is a difference between the group before drinking and the group after drinking. In the analysis of correlation in each group, it was proved that the drunken group was of significance.
        4,500원
        14.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Methyl mercaptan (MT) is one of the 22 legal designated odorous compounds in Korea. It has been reported as the main malodorous compounds of odor problems found from foot-and-mouth disease in 2012. This study on the removal of MT using the pallet-type activated carbon fiber (ACF) was carried out to get an optimum inflow loading rate and an optimum residence time required for the effective ACF odor removal device. As a result of the study, if the loading rate of MT runs at or below 0.5 g-S/kg dry ACF/d, MT removal rate by ACF could reach about 95%. However, based on the effect of Dimethyl Disulfide (DMDS) which is the reaction product of MT partial oxidation, it was estimated that the deodorizer of ACF should keep the optimum loading rate of MT less than or equal to 0.2 g-S/kg dry ACF/d. When ACF deodorizers were processed with Space Velocity (SV) at 600 h-1, the effect of DMDS was found, even though MT was not detected at the outlet. Therefore, in order to meet the outlet gas of the odor concentration which is less than or equal to 100 D/T, it is recommended that the optimum values of SV and EBRT were less than 300 h-1 and more than 12 seconds, respectively.
        4,000원
        15.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was aimed to evaluate the relationship between the concentration and dilution factor (ratio) using the Air Dilution Olfactory Method, which is suggested in the Standard Method of Odor Compounds, by measuring dilution factor for 5 types of aldehyde compounds and styrene. For the measurement, 13 panelists were selected by several criteria through panel test. Panelists chosen for their closely similar sensitivities provide more reproducible values. The estimation showed that the correlation of the concentration with dilution factor for the 12 compounds including the sulfur compounds, ammonia, and trimethylamine can be reasonably expressed by the equation log C=Af∙logD+F(Af: material constant, F: constant). The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration on site boundary in operation, as well as a correlation between the concentration and dilution factor for the designated foul odor substances, and their characteristics.
        4,000원
        17.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the relationship with the concentration and dilution factor using the Air Dilution Olfactory Method, which is suggested in the Standard Method of Odor Compounds, by measuring dilution factor for 4 types of sulfur compounds, ammonia, and trimethylamine. For the measurement, 13 panelists were selected by several criteria through a panel test. Panelists chosen for their closely similar sensitiviyies provide more reproducible values. The estimation showed that the correlation of the concentration with dilution factor for the 6 compounds can be reasonably expressed by the equation logC=AfㆍlogD+F (Af: material costant, F: constant). The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration on site boundary in operation, as well as a correlation between the concentration and dilution factor for the designated foul odor substances, and their characteristics.
        4,000원
        18.
        2012.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research determined the threshold value of 12 specified offensive odor substances based on the 3 point comparison sensory method. The panelist’s thresholds were calculated by taking the arithmetic, geometric mean, and 50th percentile. Three methods of calculating the odor thresholds from the same data are compared. For 12 odor substances, the panelist’s thresholds were showed logarithmically normal distribution. The 50th percentile was the best method among the three methods of caculating the odor threshold from the 72 panel’s thresholdes. As a result, the threshold values of individual odor substances, including methyl mercaptane, hydrogen sulfide, trimethylamine, and i-valeraldehyde ranged between 0.0001~0.001 ppm, while the values of styrene and ammonia were relatively higher than of other substances at 0.089 ppm and 3.2 ppm, respectively. The threshold values of the 12 specified odor substances were compared in Korea and overseas, which showed that the characteristics of sensory response varied by substance and nation.
        4,000원
        19.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Investigation of the odor source is necessary to establish of the effective counter plan for reducing the odor emitted from the industrial complexes. This study was carried out to investigate the characteristics of the odor emitted from leather manufacturing plants, using three methods which are a direct sensory technique, an air dilution sensory test and a instrumental analysis. Total 7 samples were sampled at 3 points of three factories in this study. As a results of this study, while odor intensity of 7 samples ranges from 2 degree to 4 degree, dilution ration of olfactory test shows the range from 300 to 600. It was estimated that main malodorous compounds ordered hydrogen sulfide, methyl mercaptan, i-valeraldehyde.
        4,000원
        20.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to understand the correlation between odor intensity and dilution factor using the Air Dilution Olfactory Method, which is suggested in the Standard method of Odor Compounds, by measuring odor intensity and dilution factor for NH₃, TMA and styrene. For the measurement, 13 panel members were selected through a panel test, and odor intensity and dilution factor by substance produced from the selected panel were estimated. The estimation showed that the correlation of odor intensity with dilution factor for NH₃, TMA and styrene can be reasonably expressed by the equation [I=AㆍLog D +0.5]. The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration at a boundary site in operation, as well as a correlation between odor intensity, concentration and dilution factor for the designated odor substances, and their characteristics.
        4,000원
        1 2 3