Long span structures like space-structures have instability phenomenon, jump buckling or bifurcation. And these instability phenomenon responds very sensitivity, depend on the initial condition. In this study, define the 1-degree of freedom space structure and when model has beating load, analysis critical load of model using 3D contour map for load, variable , displacement in the axial. The analysis results, when is 1.0, is able to see the lowest critical load and the resonance phenomenon.
In this study, an analytical study on the effect of the support structure deflection on the impact test result was carried out to set up the accurate impact test method. Various impact analyses of the CEDM(control element drive mechanisms) impact test were performed using LS-DYNA commercial FE program. Finally, the effect of the boundary condition of the support structure and impact loading duration were investigated.
This study proposes a measurement method using angular sensors to measure deformation and displacement of bridges. The proposed measurement method consists of gyroscope sensors and data processor to transform angular to vertical displacement. This study contains experimental evaluation to verify the applicability of the proposed method. 3-points bending tests were conducted on a small-sized girder specimen. The displacements were measured with both conventional LVDT and gyroscope sensor to compare the accuracy of the proposed method. It is estimated that the method using gyroscope shows some noise in data, but the method using gyroscope has advantages to measure the vertical displacement. Therefore if the sampling rate and synchronizing problems can be approved, it can be a good alternative measuring method for the deformation of the bridges.
From the past, space structure have been widely used as sports arenas, religious facilities. And the demand and research for retractable structure is increasing recently. Therefore, we classify the retractable mechanism which is divided according to the retractable method of structures and survey the present condition of retractable structures built around the world.
This study proposes a measurement method using angular sensors to measure deformation and displacement of bridges. The proposed measurement method consists of gyroscope sensors and data processor to transform angular to vertical displacement. This study contains experimental evaluation to verify the applicability of the proposed method. 4-points bending tests were conducted on a small-sized girder specimen. The displacements were measured with both conventional LVDT and gyroscope sensor to compare the accuracy of the proposed method. It is estimated that the method using gyroscope shows some noise in data, but the method using gyroscope has advantages to measure the vertical displacement. Therefore if the sampling rate and synchronizing problems can be approved, it can be a good alternative measuring method for the deformation of the bridges.
Structural performance of cable-bridge has been evaluated based on the field load test and the measurement monitoring system of existing Nielsen arch bridge. The measured acceleration data was converted to the displacement of girder and the tension of cable in the process of numerical integration and maximum frequency detection algorithm..
These days, inexpensive and high efficiency UAV(Unmanned Aerial Vehicles) of disaster prevention and spatial information has been given more attention. But studies about test of accuracy of UAV were not enough despite high interest. UAV technology has been developed for military purposes, but in recent years, it has been used for various purposes in different forms in the private sector as spread to the public sector. However, since the study applying the UAV technologies to the inspection and maintenance of structures are insufficient so far, this study suggests an application method of UAV technology for inspection and investigation of infrastructure facilities. If the UAV technology is used in inspection and investigation of infrastructure facilities, it will be able to conduct a safety check and inspect high areas and narrow passages, which are difficult or impossible to access by manpower, and further improve the safety of the structure.
In here, a Modified Diagrid Structural System (MDSS) has been proposed to compare with diagrid structural system, Regular Frame with Optimized Single Tuned Mass Damper (RFwOSTMD) system and Regular Frame without Optimized Single Tuned Mass Damper (RFwoOSTMD) system. To this aim, a rectangular reinforced cement concrete (R.C.C) building and a diagrid R.C.C multi-storey building were considered, and analyzed without controlling device, with optimized TMD, Diagrid Structural System (DSS), and MDSS. All of the models are investigated by using SAP2000. All of the buildings are analyzed and evaluated under El-centro earthquake. The response of proposed MDSS under earthquake is compared with the RFwoOSTMD, RFwOSTMD and DSS. The results show that the proposed MDSS is preferable than the DSS, as well as RFwOSTMD.
The purpose of this study is to estimate structural integrity evaluation of the concrete pontoon structure when the boundary condition and time changes. The structural integrity evaluation is conducted through the system identification method using dynamic properties. Dynamic properties are extracted with the structures when it is located on the ground and submerged in the sea. The variation of the structural stiffness due to a certain period time is discussed.
본 연구에서는 월성 중₩저준위방사성폐기물 처분시설의 내구성 및 한계수명을 예측하였다. 처분시설은 6개의 사일로로 구 성되어 있으며 지하수 포화대에 위치하고 있어 주변 지하수와 화학적 침식 등에 의한 열화에 노출되어 있으며, 장시간이 흐 르면 수리적 방벽으로서의 역할을 상실할 것으로 예상된다. 각각의 인자에 대한 열화시간을 평가한 결과 황산염 및 마그네 슘에 의한 콘크리트 열화속도는 1.308×10-3 cm/yr로 48,000 년 이상인 것으로 나타났으며, 수산화칼슘 침출에 의한 영향은 1,000 년의 기간 경과에서 수산화칼슘 유출 깊이는 1.5 cm이하로 상당히 오랜 시간이 소요되는 것으로 나타났다. 마지막으 로 염해에 의한 철근 부식의 경우 철근 부식개시기간이 1,648 년으로, 최종적으로 구조물이 한계수명 상태에 도달하는 시간 은 2,288 년인 것으로 예측되어 가장 민감한 인자로 평가되었다.
모듈러 구조물은 관행적으로 철골 모멘트 저항골조와 유사한 횡력저항성능을 가진다는 가정하에 내진 설계된다. 하지만 모듈러 구 조물은 중첩된 구조 부재와 단위 모듈의 체결을 위한 복잡한 접합 상세를 가지기 때문에 철골 모멘트 골조와 다른 하중 전달 메커니즘을 가진 다. 본 연구에서는 중첩된 구조 부재 효과와 접합부의 거동 특성을 고려하여 총 4개의 구조해석 모델을 수립하였으며, 수립된 해석 모델을 이용 하여 3층과 5층 표본 건물에 대한 비선형 정적 해석을 수행하였다. 표본 건물은 중첩된 구조 부재와 접합부의 이력 거동에 대한 모델링 방법에 따라 강성 및 강도의 차이가 발생하는 것으로 나타났다. 중첩된 구조 부재를 완전 합성, 모듈 간 접합부를 강접합으로 고려하여 설계된 모듈러 구조물은 횡 강성 및 강도가 과대 평가되는 것으로 나타났다. 뿐만 아니라 해석 결과를 통해 3층 이상의 모듈러 구조물은 철골 모멘트 저항골조 와 비교하여 상대적으로 적은 초과 강도를 가지는 것을 확인할 수 있다.
현재 대형 빌딩이나 공동주택에 건설되는 지하구조물은 건조수축, 시공이음, 폼타이부 등에서 콘크리트 균열로 인한 누수가 많이 발생되고 있다. 누수가 발생하게 되면 구조물의 지하공간은 결로, 곰팡이 등이 발생되어 지하 환경을 악화시키고 구조물의 콘크리트로 흡수되 면 철근의 부식 등을 유발하여 구조물의 안전을 위협한다. 이는 지하구조물의 사용과정에서 장기적인 쾌적성과 구조물에 안전성이 고려되지 않은 설계와 시공의 결과이며 누수 하자에 대하여 유도배수처리로 대응하기 때문에 근본적인 누수보수가 이루어지지 않아 지하구조물은 항시 누수를 허용하고 있는 실정이다. 따라서 본 연구에서는 지하에 적용되는 방수공법을 내방수와 외방수로 분류하고 이를 바탕으로 지하구조물 과 유사한 간이시험체를 제작하였으며, 결로가 많이 발생되는 동절기의 온도조건을 기준으로 지하환경의 방수공법별 습도변화량을 분석할 것 이다.
대다수의 흙막이 공사 계측현장에서 적용하고 있는 절대치 관리방법은 관리기준치와 계측결과를 절대 비교함으로서 공사현장의 안전성을 평가하는 기법이다. 따라서, 안전성 평가의 판단기준이 되는 관리기준치는 평가결과에 직접적으로 영향을 미치게 된다. 즉 아무리 최 적의 계측시스템이 적용된 현장이라고 하더라도 관리기준치가 타당하지 않으면, 공사현장의 안전성을 정확히 판단할 수 없으므로 관리기준치 의 선정은 매우 중요하다. 그러나 실질적으로 현장 기술자 등은 기존 절대치관리기준치에 대한 신뢰성이 매우 낮으며 관리기준치의 수정보완 의 필요성을 인식하고 있다. 이에 본 연구에서는 계측관리기준치의 수정보완 필요성에 대한 조사결과를 바탕으로 하여 흙막이 구조물의 거동 중 가장 기본이 되며 중요한 흙막이 벽체의 변위에 대한 계측결과를 토대로 확률론적 이론에 의해 관리기준치를 보다 적절하게 설정하여 적용 하는 연구를 수행하였다. 본 연구에서는 계측관리기법 중 시공 전에 설정된 관리기준치와 시공 시 측정된 설측치를 비교 검토하여 그 시점에서 공사의 안전성을 확인하는 방법인 절대치관리방법을 적용하여 관리기준치를 수정하였다.
구조물의 수명관리는 일반적으로 불확실성의 효율적 고려를 위해 신뢰성 이론을 적용한다. 전체 구조시스템의 신뢰성 평가는 구조 요소의 신뢰성 평가와 구조시스템의 모델링을 통해 이루어진다. 구조시스템은 신뢰도에 대한 구조요소의 역할과 기여도를 고려하여 모델링 된 다. 따라서, 구조시스템의 신뢰도는 구조요소의 모델링과 구조요소의 상관관계에 따라 서로 다른 결과를 제시하게 된다. 최초 구조시스템의 신 뢰도 평가와 열화요소를 반영한 구조시스템의 수명 평가를 바탕으로 생애주기 비용 최소화와 관련된 목적함수를 가지는 최적화 과정을 통해 수 명관리가 이루어진다. 본 논문에서는 구조시스템을 구성하는 구조요소의 상관관계와 더불어 기존의 연구에서 고려된 바 없는 유지보수 간의 상 관관계에 따른 수명평가 영향분석을 수행하며, 이를 통해 향후 좀 더 효율적인 수명관리 기법 개발에 활용하고자 한다. 또한, 예방유지보수와 필 수유지보수를 모두 고려하며, 유지보수간 독립 상태와 완전상관 상태에 따른 수명 예측 및 최적화 유지보수 계획 수립을 비교 제시한다.
이 연구의 목적은 개착식 전력구 콘크리트에 발생하는 부등건조수축에 의한 균열특성을 파악하고, 그 제어방법을 제시하는데 있 다. 건조수축균열은 콘크리트 내부의 수분확산계수의 영향을 크게 받으며, 수분확산계수는 콘크리트 내부에서의 수분이동속도를 결정하는 주요인자이다. 수분확산계수와 더불어 콘크리트 표면의 표면계수와 외부의 상대습도는 콘크리트 내부에서 외부로의 수분이동에 영향을 미친 다. 따라서 이 연구에서는 전력구 박스형 콘크리트 구조물의 부등건조수축에 의한 균열특성을 파악하기 위하여 세 가지 주요영향인자를 고려 한 수치해석을 수행하였다. 수치해석 결과, 수분확산계수와 표면계수가 증가할수록 상부슬래브의 부등건조수축에 의한 균열발생시점이 빨라 지며, 세 가지 요인 중에 콘크리트의 부등건조수축에 의한 균열발생 특성에 가장 큰 영향을 미치는 것은 외기습도인 것으로 나타났다. 이 연구 결과를 분석한 결과, 개착식 전력구 시공시에 콘크리트 타설 후 표면보습이나 살수양생과 같이 외기습도를 증가시키는 것이 부등건조수축에 의한 균열제어에 가장 효과적인 것으로 판단되며, 콘크리트 재료적 측면의 균열저감방법으로 수분확산계수와 표면계수를 결정하는 콘크리트 의 배합이나 재료특성을 적절히 선정함으로써 균열의 진전속도나 발생시점을 제어할 수 있을 것으로 판단된다.