This study examines on the structural Methods between purlin and beam at Wooden Architecture in Joseon Dynasty(1372~1910). Through the investigation, it is verified that the structural methods between purlin and beam is the technique utilizing tenon joint(통장부맞춤), Sungeoteok joint(숭어턱맞춤), dovetailed tenon joint(주먹장맞춤). And the methods of tenon joint is followed by the Sungeoteok joint, which is used in the buildings after middle Joseon dynasty. The method of tenon joint(통장부맞춤) is to connect the beam with the purlin by carving out the head of the beam as '一' shape. And the structural methods between Janghyeo(장혀, timber under purlin) and beam is halved joint(반턱맞춤) and tenon joint (통장부맞춤). The buildings in late Goryeo Dynasty and Joseon Dynasty adopted the method of tenon joint between purlin and beam. The method of Sungeoteok joint is to connect the beam with the purlins by carving out the head of the beams '凸' shape. And the structural methods between Janghyeo and beams is halved joint(반턱맞춤) and tenon joint(통장부맞춤), the method of tenon and step joint(통장부턱맞춤), dovetailed joint between beam and Janghyeo to increase the security of shear force.
이 연구에서는 새로운 접합장치인 자동체결장치(Self-Locking Connectors)를 사용한 강재보-PC기둥 접합부의 내진성능에 대한 연구를 수행하였다. PC기둥(또는 합성기둥)과 강재보로 이루어진 합성모멘트골조는 각각의 재료의 장점을 최대한으로 이용한 합리적인 구조형식이다. 그러나 서로 다른 두 재료 사이의 접합에 따른 어려움으로 인해 접합부의 상세가 복잡해지고 제작비가 상승하는 단점을 가지고 있다. 반면에 자동체결장치는 쐐기의 원리를 이용한 접합장치로서 시공이 단순한 장점이 있다. 또한 자동체결장치를 사용한 접합부는 용접을 사용하지 않음으로써 기존의 접합부에 비해 내진성능을 개선할 수 있다. 본 연구에서는 자동체결장치를 사용한 강재보-PC기둥(또는 합성기둥) 접합부에 대한 내진성능을 검증하기 위해 반복하중 실험을 수행하였다. 실험결과 자동체결장치를 사용한 보-기둥 접합부는 우수한 내진성능을 발휘할 수 있는 것으로 나타났다.
본 조사에서는 경기도 경안천의 중류에 위치한 소형보를 철거한 이후에 변화된 저서성 대형무척추동물의 군집을 조사하였다. 조사는 보가 있었던 지점의 상류와 하류, 그리고 중류 (보의 자리)에서 보의 철거 후 4회 (2004년 11월, 2005년 5월, 2006년 1월, 그리고 2006년 5월)에 걸쳐 Surber sampler (50×50 cm, 망목 0.25 mm)로 정량채집을 하였다. 조사의 결과, 조사지역에서는 총 4문 5강 11목 27과
본 논문에서는 철근콘크리트 모멘트 골조의 보-기둥 접합부에 대한 비탄성 회전 능력의 성능을 조사한 연구 결과를 하고 있다. 총 91개의 보-기둥 접합부 실험체에 대해 상세히 조사되었으며, 그 중 28개의 실험체는 ACI 318-02의 상세 요구에 기초하여 특수 모멘트 골조 접합부로서 분류되었다. AISC-97 내진 기준에서 철골 모멘트 골조 접합부를 위해 정의된 허용기준이 분류된 철근콘크리트 모멘트 골조의 접합부에 대해 평가하기 위해서 사용되었다. 특수 모멘트 골조 접합부에 대한 설계 상세를 만족하는 28개의 실험체 중 27개의 특수 모멘트 골조 접합부가 충분한 강도를 가지고 있었으며, 급격한 강도 감소 없이 0.03 rad.의 소성 회전에 대해 연성 거동을 발휘할 수 있음을 보여 주었다. 접합부의 전단 강도, 기둥과 보에 대한 휨 강도 비율, 접합부내에서의 횡방향 철근비 등에 대한 제한이 보-기둥 접합부의 만족스런 내진 성능을 보여주는데 중요한 역할을 하였다.
위상최적화기법을 이용하여 보의 기본고유진동수 최대화문제를 수행하였다. 도입된 위상최적화기법은 구조물의 모드형상에 의해서 발생되는 모드변형에너지를 바탕으로 한다. 최소화하고자하는 모드변형에너지를 목적함수로 하고 구조물의 초기부피를 제약함수로 채택하였다. 최적정기준법을 바탕으로 한 크기조절알고리듬을 유한요소내부에 존재하는 셀의 빈공간의 크기를 조절하기 위해 도입하였다. 세 가지의 다른 경계조건을 가지는 보를 이용하여 자유진동모드형상에 저항하는 보의 최적위상을 조사하였다. 수치해석결과로부터 도입된 위상최적화기법을 이용하여 도출한 보의 최적위상은 초기구조물에 비해 저차의 자유진동수가 크게 증가하는 것으로 나타났으며 특히 모드변형에너지를 이용하는 위상최적화의 경우에는 구조물의 기본진동수를 최대화하는데 매우 효과적인 것으로 나타났다.
본 논문에서는 보 구조물의 실시간 손상위치 경보를 위해 가속도 신호를 이용한 인공신경망기반 손상검색기법을 제안하였다. 이를 위해 먼저, 실시간 손상검색을 위해 가속도 응답신호만을 이용하는 새로운 인공신경망 알고리즘을 설계하였다. 구조물의 손상상태를 나타내는 특징으로 서로 다른 두 위치에서 측정된 가속도 신호의 교차공분산 값을 이용하였다. 다음으로 실제 하중조건을 모르는 상황을 고려하여 다양한 하중패턴에 따른 복수 신경망을 구성하였으며, 각각의 신경망 학습을 위한 손상시나리오를 선정하였다. 마지막으로 양단 자유보 모형실험을 통해 제안된 기법의 유용성과 적용성을 평가하였다.
FRP를 이용한 보강법 중에서도 기존에 일반적으로 행해진 보강법은 Plate 또는 Sheet의 형태로 콘크리트 표면에 부착하여 추가적인 강도를 발현하도록 하는 것이다. 그러나 조기 박락파괴, 부착면의 정리, 보강 단부의 앵커시공, 부착면에 대한 내화처리 등의 어려움이 많다. 이러한 문제점들에 대한 방안으로 막대(Rod) 형태인 CFRP-Rod를 보강모체에 홈을 파고 매립하는 NSMR(Near Surface Mounted Reinforcement)공법이 제안되었고, CFRP-Rod의 보강량, 길이, 간격 등의 변수에 의한 휨보강 능력의 평가에 대한 연구가 이루어져왔다. 그러나 구조물에서 CFRP-Rod의 보강은 어느 정도의 하중이 보강부위에 계속 재하된 상태로 보강이 이루어지게 되므로 본 연구에서는 보강전에 가해지는 선하중(Pre-loading)의 크기를 주요변수로 선하중의 크기에 따른 구조물의 거동 특성을 분석하고자 하였고, 선하중의 크기의 결정은 무보강 시험체의 공칭모멘트와의 비로 결정하였다.
탄소섬유관으로 구속된 원형 무근콘크리트 부재는 콘크리트에 효과적인 횡구속을 제공하며, 섬유의 우수한 역학적 성질로 인하여 기존의 철근을 대체할 수 있는 우수한 합성부재이다. 본 논문에서는 탄소섬유관으로 구속된 원형 무근콘크리트 보에 관한 실험 및 해석연구를 실시하였다. 실험연구에서 시험체는 두께 1.5mm(3장), 2.0mm(4장), 2.5mm(5장) 및 3.0mm(6장)를 변수로 하여 실험을 실시하였다. 구속된 콘크리트의 압축강도를 예측하는 식을 이용하여 본 연구에서는 탄소섬유 관으로 구속된 원형 무근 콘크리트 보의 휨성능을 예측하는 실험식을 제안하였다.
This work was performed to investigate the distribution of the fuel droplet size around the bluff-body and the combustion characteristics. The geometry of the bluff-body influenced the spray shape and the combustion characteristics. Diameters of the bluff-body in this experiment are 6, 8, and 10mm and the impingement angles( θ) are 30°, 60°, and 90°. The measurement points were at the distances of 20 and 30mm axially from the nozzle. The SMD and Rosin-Rammler distribution was acquired by image processing technique(PMAS), and the mean temperatures were measured by thermocouple. The results obtained are as follows; In the condition of θ=60°, the values of SMD are not greatly varied compared to the other conditions. As the impingement angle of bluff-body was increased, the high temperature region was wider along radial direction. When the air-fuel ratio was increased, the CO concentration was decreased.
Korea is closed to China in the geographical position and is related to China as two countries have developed similar culture, art, and social systems. Architecture is a kind of culture and has advanced in the wooden architecture with a considerable change. The study investigated a phylogenetic relationship between two countries based on characteristics of architectural universality. With comparison and analysis on the common feature and difference of the beam and structure in the wooden architecture from the Koryo and Zhejiang Province(China), the systemicity of the wooden architecture was examined. The beam is a part of timber which is consist of the wooden structure frame and also a crucial subject to understand a development process of the wooden architecture.
본 논문에서는 철골 각형강관단면(RHS) 기둥-보 접합부에서 웨브의 모멘트 전달효율을 평가하였다. 먼저, 5개의 철골보접합부에 대한 비선형 유한요소해석을 수행하였다. 이들은 접합부 상세가 다르게 설계되었고, 따라서 휨저항 성능이 각기 다르다. 해석결과 RHS 기둥을 가진 모델은 기둥 플랜지의 면외변형 때문에 WF(Wide Flange) 기둥을 가진 모델에 비해 모멘트 전달효율이 저하함을 보였다. 스캘럽(WAH)과 얇은 강관기둥 두께도 모멘트 전달효율의 저하를 가져오는 원인으로서, 결과적으로 보-기둥 접합부의 파단을 초래할 가능성이 크다. 해석과 이전의 실험결과를 기초로 하면, 응력집중은 모멘트 전달효율과 반비례하고, 접합부의 변형능력은 모멘트 전달효율의 저하에 따라 감소하는 것을 알 수 있다. 더 나아가서 바닥슬래브가 있는 합성보 접합부에 대한 유한요소해석결과는 중립축이 상부플랜지 방향으로 상승함으로써 모멘트 전달효율이 저하했고, 이러한 영향은 접합부의 조기 취성파단을 초래하는 것을 보였다.
최근 FRP Plate를 이용한 철근콘크리트 구조물의 보수보강 방법으로 많은 연구가 수행되어 왔다. 이러한 FRP Plate로 보강된 구조물의 경우 보강재 단부의 조기탈락에 대한 문제점이 많은 연구를 통하여 지적되었다. 본 논문은 이러한 보강재 단부의 조기탈락에 대한 대안으로 CFRP Plate 외부부착공법에 있어서 단부를 보강철물을 이용하여 2차적으로 보강하는 방법 및 CFRP-Rod 표면매립공법으로 횝 보강된 철근콘크리트 보의 구조적 거동 및 휨 보강 성능을 파악하는데 그 목적이 있다. 또한 보강 방법에 따른 효과적인 휨 보강 성능을 파악하기 위하여 CFRP Plate 외부부착공법과 CFRP-Rod 표면매립공법을 실험을 통하여 이를 비교 고찰하여 휨 보강 성능효과를 알아본다.
콘크리트 부재의 내진설계에 있어 강도와 더불어 변형 능력은 중요한 요소이다. 연결보는 전단 지배 부재임에도 항복 이후 소성 변형을 요구하는 부재인데 본 연구에서는 연결보의 변형 능력에 대한 실험을 통해 변형 모형을 제시하였다. 일반적인 배근 형태를 가진 철근 콘크리트 연결보를 대상으로 단조하중실험을 수행하였다. 경간-깊이비, 휨 철근비, 전단 철근비를 변수로 하여 연결보의 거동을 평가하였다. 전단 지배 부재인 연결보는 아치작용과 트러스 작용으로 전단력에 대해 저항하는데 실험 결과를 통해 전단력을 두 작용의 구분과 항복 강도 발현 이후 소성 변형에 따른 두 작용의 구성비 변화에 대해 분석하였다. 실험결과에 기초한 전단 철근과 휨 철근의 변형률 분포 모형을 이용하여 휨 철근의 응력 상태를 산정하였다. 휨 철근의 부착-미끄러짐에 의해 결정되는 균열폭을 고려하는 연결보의 변형 모형을 제시하였다. 항복 상태는 휨 철근의 항복 시점으로 정의하였고, 극한 상태는 변형 증가에 따른 스트럿의 압축 강도 저하에 의해 결정되었다. 이 변형 모형은 변위기초설계에 활용될 수 있을 것으로 기대된다.