검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 17

        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Demonstrated performance degradation of LiDAR for vehicle and pedestrian dummy in rainy and foggy road conditions. METHODS : In real-scale rain and fog road conditions, adjust the distance between LiDAR and the measurement target from 10m to 70m (in 10m interval), measure LiDAR NPC (number of point cloud) and intensity, and compare the resulting numerical values. RESULTS : LiDAR's NPC and Intensity showed statistically significant differences by overall weather condition (normal, rain, fog), and the values were found to be larger in the order of normal>rainfall>fog. In the case of vehicles, sunder rain conditions, NPC and intensity are recognized even at 70m as in normal conditions, but under fog conditions, NPC and intensity are measured only up to 30m. In the case of pedestrians, the reflective area size is smaller than that of vehicles, so they are recognized only up to 30m in rainy conditions, and NPC and intensity are measured only up to 20m in fog conditions. CONCLUSIONS : It was confirmed that LiDAR performance deteriorates in rain and fog compared to normal.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 초분광 영상으로 두 품종의 콩(청자 3호, 대찬)의 들불병을 진단할 수 있는 모델과 다중분광 영상센서를 개발하기 위해 수행되었다. 무처리구와 들불병 처리구에서 5 nm full width at half maximum (FWHM)으로 구성된 원시 초분광 중심파장들의 콩 식물 영역 반사율들을 추출하여 10 nm FWHM으로 병합한 후, t-test로 차이가 나타난 blue, green, red, red edge, NIR1 및 NIR2 각 영역에서 선정된 대표 밴드로 121개의 식생지수를 계산하였다. 식생지수를 입력변수로 support vector machine (SVM), random forest (RF), extra tree (EXT), extreme gradient boosting (XGB)의 머신러닝 기법과 shapley additive explanation 변수 선택 기법을 적용하여 들불병 진단에 가장 적절한 모델을 선정하고 사용된 식생지수와 파라미터를 나타내었다. T-test 결과 품종에 상관없이 blue 1개(420 nm), green 2개(500, 540 nm), red 1개(600 nm), red edge 2개(680, 700 nm), NIR1 2개(780, 840 nm), NIR2 1개(920 nm)의 총 9개 대표 밴드들이 선택되었고, 성능 평가를 통해 선정된 모델에 청자 3호의 경우 SVM모델(OA=0.86, KC=0.72, 10 VIs)이 선정되었으나 혼동행렬 분석 결과 정상오분류가 적은 RF모델이 선택되었다. RF모델(식 생지수 : RE/Blue, NSI, GDVI, Green/Blue, 파라미터 : max_depth=6, n_estimators=100)은 OA=0.81, KC=0.60, precision=0.86, recall=0.81, F1 score=0.80의 성능을 나타내었다. 대찬은 EXT모델(식생지수 : YVI, RE/Green, 2YVI, 파라미터 : max_depth=8, n_estimators=10)이 선정되 었고, OA=0.86, KC=0.72, precision=0.86, recall=0.86, F1 score=0.86의 성능을 나타내었다.
        4,600원
        3.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : LED based Variable Message Signs(VMS) have been widely used to inform safety messages to the drivers in advance. Legibility Distance of VMS is the most important factor to provide the safety messages to drivers in timely and effective way. However, current National Standards on legibility distance design considers letter size only even there is a difficulty to read the signs at adverse weather conditions such as heavy fog. So, this study examined the legibility issue under fog by evaluating the legibility distance with two design factors such as letter size and luminance. METHODS : Two foggy weather conditions, intermediate and heavy fog, were simulated at real-road-scale Proving Ground. Legibility distance at daytime and nighttime was evaluated by test subjects. Subjects were asked to fill the legible distance on the test sheet and statistical significant was analysed at the lab. RESULTS : The legibility distance(LD) under fog was observed only 22 to 41% of LD observed under normal weather condition at daytime, and 26 to 45% at nighttime condition. Study results showed a consistent increase in LD with higher luminance even at same letter size and vice versa conditions, However, statically significant difference between groups was only revealed when both letter size and luminance level increased conditions. In order to apply the test results in terms of engineering benefits, LD results from significantly different groups was evaluated with relative to Stopping Sight Distance(SSD) within conceptual frame suggested in this study. CONCLUSIONS : From the study results, current National Standard on legibility distance design needs to consider letter size and luminance simultaneously to response the legibility issue in adverse weather conditions.
        4,000원
        4.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study analyzes the characteristics of nitrogen oxide concentration by applying titanium dioxide to existing roads in urban areas, using correlation analysis and a generalized linear model. METHODS : To analyze the characteristics of nitrogen oxide concentration with/without applying titanium dioxide to the urban road segment, data acquisition was conducted for nitrogen oxide concentration, weather information, and traffic information, etc., and a correlation analysis was conducted for each factor, with/without applying titanium dioxide to the roads. In addition, nitrogen oxide concentration generation models with/without the application of titanium dioxide to the roads were estimated using a generalized linear model. RESULTS : The results demonstrate that relative humidity and temperature were found to be slightly correlated with the nitrogen oxide concentration, both with and without the application of titanium dioxide to the roads; however, wind speed, solar radiation, and traffic volume were found to have somewhat low correlation according to the results of a correlation analysis. Moreover, relative humidity, temperature, solar radiation, and traffic volume were significant when titanium dioxide was applied to the roads, based on the estimated model from a generalized linear model, and the wind speed, solar radiation, and traffic volume were significant for the absence of titanium dioxide on the roads. CONCLUSIONS : Analytical results indicated that the characteristics of nitrogen oxide concentration vary depending on the application of titanium dioxide to the roads. In particular, when titanium dioxide was applied to the roads, the relative humidity and temperature were analyzed; according to both analyses, i.e., correlation analysis and a generalized linear model, the nitrogen oxide concentration was affected.
        4,000원
        5.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to determine the characteristics of nitrogen oxide (NOx) concentration in an exclusive median bus lane station. The hourly variations of NOx concentration and the effect of traffic volume on NOx concentration were analyzed using NOx measurement data and the number of vehicles at the station. METHODS : Data were collected using the chemiluminescence method for NOx concentration. Atmospheric information and traffic volume of buses were collected from the Korea Meteorological Administration and Bus Information System, respectively. RESULTS : As a result, the NO2 concentration in the test section was found to have a strong correlation with those in the atmospheric measurement station located near the test-bed. In addition, the average NOx concentrations in the test section were significantly higher than those of the other monitoring stations due to bus emissions. The average NOx concentration in the exit section was higher than that in the entry section owing to the vehicle’s frequent stops and fuel consumption due to acceleration. During the measurement period, the average NOx concentration was measured as approximately 33 % higher in the exit section than in the entry section. In addition, the NOx concentration at the bus station was found to increase as the bus dwell time increased, rather than the number of bus passages. CONCLUSIONS : This study provides clear characteristics of the NOx correlations with traffic information in an exclusive median bus lane station. It was shown that the NOx concentration at the bus station increased as the number of passes and bus dwell time increased. According to the coefficient of determination, the dwell time is more closely correlated to the NOx concentration at the bus station than the number of bus passes, indicating that it is a better parameter for predicting NOx concentration at bus stations.
        4,000원
        6.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, the characteristics of fine particulate matter (PM2.5) concentrations under different weather conditions of different types of bus stops, such as enclosed-type and open-type bus stops, were analyzed using statistical methods. METHODS : Data was collected inside and outside an enclosed bus stop on sunny and rainy days to compare and analyze the characteristics of fine particulate matter concentration in the target bus stop. The probability distributions were estimated for each data point using the Anderson–Darling test. Based on the estimated probability distributions, probability density functions were computed, and the values were used to estimate and compare probability for each air quality index inside and outside the bus stop under different weather conditions RESULTS : For the results of descriptive statistics, the average concentrations of fine particulate matter inside and outside the bus stop were 42.296 and 35.482 μg/m3 on a sunny day and 40.831 and 39.321 μg/m3 on a rainy day, respectively. Results of the statistical method, obtained using the Anderson-Darling test, indicate that the probability of the air quality index inside the bus stop reaching high concentrations on a sunny day was "high" or "very high," compared to that outside the bus stop. However, on rainy days, the differences in fine particulate matter concentrations inside and outside the bus stops were difficult to identify based on statistical evidence. CONCLUSIONS : It was found that the open-type bus stop had an advantage of preventing fine particulate matter effects on sunny days, compared to the enclosed-type bus stops. Furthermore, there were slight differences in fine particulate matter concentrations inside and outside the bus stop on a rainy day because of atmospheric flow and stormwater.
        4,000원
        8.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study analyzes the characteristics of generated fine particulate matter (PM2.5) and nitrogen oxide (NOX) at roadsides using a statistical method, namely, a generalized linear model (GLM). The study also investigates the applicability and capability of a machine learning methods such as a generalized regression neural network (GRNN) for predicting PM2.5 and NOX generations. METHODS : To analyze the characteristics of PM2.5 and NOX generations at roadsides, data acquisition was conducted in a specific segment of roads, and PM2.5 and NOX prediction models were estimated using GLM. In addition, to investigate the applicability and capability of a machine learning methods, PM2.5 and NOX prediction models were estimated using a GRNN and were compared with models employing previously estimated GLMs using r-square, mean absolute deviation (MAD), mean absolute percentage error (MAPE), and root mean square error (RMSE) as parameters. RESULTS : Results revealed that relative humidity, wind speed, and traffic volume were significant for both PM2.5 and NOX prediction models based on estimated models from a GLM. In addition, to compare the applicability and capability of the GLM and GRNN models (i.e., PM2.5 and NOX prediction models), the GRNN model of PM2.5 and NOX prediction was found to yield better statistical significance for r-square, MAD, MAPE, and RMSE as compared with the same parameters used in the GLM. CONCLUSIONS : Analytical results indicated that a higher relative humidity and traffic volume could lead to higher PM2.5 and NOX concentrations. By contrast, lower wind speed could affect higher PM2.5 and NOX concentrations at roadsides. In addition, based on a comparison of two statistical methods (i.e., GLM and GRNN models used to estimate PM2.5 and NOX), GRNN model yielded better statistical significance as compared with GLM.
        4,000원
        9.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The objective of this study is to evaluate the shear and tensile strength properties of adhesive road studs in asphalt and concrete pavements. METHODS: The 300 mm×300 mm×50 mm rectangular specimens were fabricated using asphalt and concrete mixture for installation of road studs. Four 140-mm-radius circular areas were milled on each specimen with depth of 5 mm to install the adhesive road studs. About 100 g of thermal melting adhesive was applied on the milled area, and then the road stud was bonded onto the surface of the asphalt and concrete mixture. Direct shear testing was conducted at a speed of 5 mm/min on the interface between road stud and asphalt and concrete materials. Tensile strength testing was also conducted on the prepared specimens by applying load with increase of 50 kPa per second. These tests were performed not only in dry condition but also in wet condition to determine the effect of moisture on the shear and tensile strengths. RESULTS : According to the shear testing results, the average shear strength of asphalt samples in dry and wet conditions are 0.509 and 0.234 MPa, respectively. From this testing, the shear strength of wet sample was found to be decreased by 50% with respect to that of the dry sample. Similar trends can be observed on the concrete samples. The average tensile strength of asphalt samples was 0.187 MPa at 1.5 mm of displacement in dry condition. The concrete sample has a 0.222 MPa average tensile strength, which is slightly higher than that of the asphalt sample because of the rough surface characteristics of the concrete sample. CONCLUSIONS: It is determined from this study that the shear and tensile strengths of road stud bonded on the surface of asphalt mixture are slightly lower than those on concrete samples. Regardless of the pavement type, the wet conditioning of the sample can decrease the shear and tensile strength by 50% those of the dry sample. In the future, the quality improvement of adhesive and increase of specific surface area should be considered to improve the bonding property between road stud and pavement surface.
        4,000원
        10.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The objective of this study is to evaluate the physical properties of recycled asphalt mixtures reinforced with glass fiber. METHODS: Firstly, mixing design was conducted on recycled asphalt mixture for use of 50% recycled aggregate. Various laboratory tests were performed on four types of recycled asphalt mixtures with different glass fiber content to evaluate the physical properties. The laboratory tests include indirect tensile strength test, dynamic modulus test, Hamburg wheel tracking test and tensile-strength ratio to evaluate cracks, rutting and moisture resistance of mixtures. RESULTS: The indirect tensile strength of fiber reinforced glass increased about 139.4%. As a result of comparing the master curves obtained by the dynamic modulus test, the elasticity was low in the low temperature region and high in the high temperature region when the glass fiber was reinforced. The glass fiber contents of PEGS 0.3%, Micro PPGF 0.1% and Macro PPGF 0.3% showed the highest moisture resistance and rutting resistance. CONCLUSIONS : The test results show that use of glass fiber reinforcement can increase the resistance to cracking, rutting, and moisture damage of asphalt mixtures. It is also necessary to validate the long-term performance of recycled asphalt mixtures with glass fiber using full scale pavement testing and field trial construction.
        4,000원
        11.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The objective of this study is to evaluate the application of soil stabilization method for soft shoulder construction in the iRoad Project of Sri Lanka. METHODS: Firstly, the quantitative analysis of soil strength improvement due to soil stabilization was done for soil samples collected from iRoad construction sites. Two types of soils were selected from iRoad Project sites and prepared for soil stabilization testing by the Road Development Authority. Secondly, the appropriate stabilizer was selected at given soil type based on test results. Two different stabilizers, ST-1 and ST-2, produced in Korea were used for estimating soil strength improvements. Finally, the optimum stabilizer content was determined for improving shoulder performance. The uniaxial compressive strength (UCS) test was conducted to evaluate the strength of stabilized soil samples in accordance with ASTM D 1633. The use of bottom ash as a stabilizer produced from power plant in Sri Lanka was also reviewed in this task. RESULTS: It is found from the UCS testing that a 3% use of soil stabilizer can improve the strength up to 2~5 times in stabilized soft shoulder soils with respect to unstabilized soils. It is also observed from UCS testing that the ST-1 shows high strength improvement in 3% of stabilizer content but the strength improvement rate with increase of stabilizer content is relatively low compared with ST-2. The ST-2 shows a low UCS value at 3% of content but the UCS values increase significantly with increase of stabilizer content. When using the ST-2 as stabilizing agent, the 5% is recommended as minimum content based on UCS testing results. Based on the testing results for bottom ash replacement, the stabilized sample with bottom ash shows the low strength value. CONCLUSIONS: This paper is intended to check the feasibility for use the soil stabilization technique for shoulder construction in Sri Lanka. The use of soil stabilizer enables to improve the durability and strength in soft shoulder materials. When applying the bottom ash as a soil stabilizer, various testings should be conducted to satisfy the specification criteria.
        4,000원
        12.
        2017.10 구독 인증기관·개인회원 무료
        본 연구는 도로함몰과 관련된 연구 중 위험도 등급에 따른 소성변형 특성을 파악하기 위해 수행되었다. 도로함몰 위험도 등급 A, B에 해당하는 지표면으로부터 60cm, 90cm 하부에 모의 동공(얼음)을 설치하였으며, 동공의 크기는 그림 1과 같이 너비와 높이는 50cm, 길이는 100cm, 200cm로 각각 설계하였다. 또한, 배수층을 20cm 설치하여 배수가 가능하도록 설계하였다. 포장가속시험은 4ton의 축하중으로 10km/h의 속도로 운영하였으며, 1,000회, 2,000회, 6,000회, 10,000회 운행 시 마다 소성변형량 변화를 측정하였다. 그 결과 동공의 크기보다는 동공의 깊이가 소성변형에 영향을 크게 미치는 것으로 파악되었다. 그림 1의 1,3번 동공은 폭과 높이는 유사하지만 길이가 각각 1m, 2m로 위험도 등급에서 B, A이다. 하지만, 소성변형량을 비교했을 때 각 횟수마다 비슷한 경향을 보이며 증가하는 추세를 볼 수 있었다. 또한, 2번 동공의 경우 포장층에 가깝게 동공이 형성되어 1,3번 동공과 달리 소성변형량 증가 추세가 다른 동공들에 비해 월등히 빨랐으며, 6,000회 이상 포장가속시험을 수행하기 어려울 정도로 소성변형이 심하게 나타났다. 포장가속시험 수행 결과 동공 생성 초기에 소성변형량 변화폭이 가장 크며, 동공 길이보다는 심도에 포장층이 영향을 크게 받는 것으로 나타났다.
        13.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the performance of a synthetic fiber filter aimed at high-speed operation and dosed with different coagulants or filter aids was investigated. Without a coagulant, the filter efficiency was about 62% which was greatly enhanced when three types of coagulants namely PAC, Alum, and FeCl3 were used. Among the coagulants tested, PAC was the most effective, giving 91% filter efficiency, followed by Alum with 90%, and FeCl3 with 78%. PAC worked effectively at a very small range of dose, but Alum was relatively effective in a wide range of concentration. Compared with PAC and Alum, FeCl3 provided more or less contant efficiency regardless of its dose but gave the poorest filter efficiency. Moreover, as the inflow turbidity increased, headloss increased and the efficiency decreased at any dose and type of coagulant. The headloss recorded in this particular synthetic fiber filter is not significant as compared to that observed in typical granular filters. The recovery of solids estimated after filter cleaning was about 80% for both PAC and Alum, but poorer at 72% in the case of FeCl3 due to the heavy and large floc characteristics. The recurrence of filter efficiency verified through repetitive filter runs was found to be satisfactory.
        4,800원
        14.
        2016.06 구독 인증기관·개인회원 무료
        국내 도로에 적용중인 포장상태지수는 도로관리 기관별로 각자의 목적에 맞도록 지표를 개발하여 사용 중이다. 국도의 NHPCI(National Highway Pavement Condition Index), 고속도로의 HPCI(Highway Pavement Condition Index), 그리고 서울시의 SPI(Seoul Pavement Index)는 각기 다양한 상태의 포장 구간을 선정하고, 구간에 대한 여러 전문가들의 평가를 수렴하기 위해 포장 관리실무자와 산·학·연의 포장 전문가들에 의해 도출되었다는 점에서는 동일하다(서영찬 외, 2008; 조병완 외, 2001; 한국도로공 사, 2013). 그러나 HPCI와 NHPCI는 패널 평가(Panel Rating)와 포장상태 조사결과를 회귀분석하여 모 델식이 개발된 반면, SPI는 일본의 포장상태 지수인 MCI(Maintenance Control Index)를 기본 모델로 사용하고 이를 패널들의 토의를 통해 계수를 수정하는 방식으로 개발되었다는 점에서 차이를 보인다. 이러한 지수들은 도로의 등급에 따라 각각의 목적에 맞는 평가지표로서 작용하는데, 국가전체 차원에 서 보면 도로의 등급에 관계없이 전체도로의 포장상태를 파악하는 것이 필요하다. 즉, 각각의 지수들은 각각의 목적에 맞게 운영하되 상관관계 분석을 통해 다양한 지수들을 하나의 통일된 지표로 나타냄으로서 전체적인 상태파악 및 예산 및 자원분배가 용이하도록 하고 도로이용자 및 관리자 간의 의사소통 수단으 로 사용될 수 있다. 본 연구에서는 국도 모니터링 시스템(그림 1 참조)의 데이터베이스를 활용하여 동일한 구간에 대해 각 지수를 산출하였다. 국도 모니터링 시스템은 전국의 도로망에서 무작위로 대표구간을 추출(Random Sampling)하여 매년 포장상태 조사를 통해 국도 전체의 포장상태 변화 추이를 감시하는 기능을 하고 있 다. 이를 통해 수집된 자료는 도로관리 정책에 반영되며 네트워크 레벨에서의 포장관리체계(PMS)의 운영 이 가능하도록 데이터베이스를 구축하는데 기여하고 있다(서영찬 외, 2008). 이러한 자료를 통한 분석으 로 국내 실정을 반영한 지수 간 비교가 이루어지도록 하였고 그 결과, 그림 2와 같은 상관관계 분석을 통 해 관계식을 도출하였다.
        15.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        상부벽식 하부골조를 가진 복합구조물은 부족한 대지를 효율적으로 활용하기 위하여 건설되고 있다. 이러한 복합건물은 상부벽식-하부골조를 가지는 구조로써 일반적으로 전이보 또는 전이판으로 상하부를 연결하고 있다. 따라서 상하부 구조사이의 강성과 질량에 많은 차이가 발생하게 된다. 구보물의 고유주기는 지진하중과 밑면전단력을 결정하기 위한 중요한 변수이다. 그러나 현재 국내 규준에서 제안하는 고유주기 산정식은 이러한 건물에는 적용할 수 없다. 본 연구에서는 상부벽식-하부골조를 가진 복합구조물의 고유주기의 산정에 영향을 미치는 변수들 중 가장 큰 영향을 미치는 건물의 상하부 층수에 따른 변수만을 고려하여 고유주기산정식을 제안하였다. 하부는 2~5개 층을 가지고, 상부는 10~18개 층을 가지는 15~20층의 건물이면 정형적인 평면을 가지는 복합구조물로 한정하였다. 건물 내부의 채움벽에 대한 효과를 고려한 고유주기 제안식은 다음과 같다. 장변 방향 : T_{L}=(0.20H_{h}+0.05H_{i})/sqrt{B}-0.42 단변 방향 :T_{S}=(0.07H_{h}+0.12H_{i})/sqrt{B}-0.40
        4,500원
        16.
        2014.09 서비스 종료(열람 제한)
        The isolated single coronary artery is a rare congenital anomaly, in which both coronary arteries arise from a solitary ostium. Diagnosis of coronary anomalies and identification of the exact anatomy of coronary arteries has significant clinical importance, hence, myocardial ischemia or sudden cardiac death is usually related to its course of anomalous coronary artery. Most patients with a single coronary artery are asymptomatic and have normal electrocardiogram and negative stress tests. However, if the patient has other structural abnormalities, for example, ventricular hypertrophy, the exam is determined. This report describes a case of single coronary artery, where the right coronary artery originated from the distal left circumflex artery in a patient with hypertrophic ardiomyopathy.