        1.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the out-of-plane seismic resistance of lightly-reinforced existing walls strengthened with thick RC jacket was investigated. The thick RC jacket with a thickness of 500 mm was placed at one side of the thin existing wall with a thickness of 150 mm. At the interface between the wall and RC jacket, a tee-shaped steel section with a number of anchor bolts and dowel bars was used as the shear connector. To investigate the connection performance and strengthening effects, the cyclic loading tests of four jacketed wall specimens were performed. The tests showed that the flexural strength of the jacketed walls under out-of-plane loading was significantly increased. During the initial behavior, the tee shear connector transferred forces successfully at the interface without slip. However, as the cracking, spalling, and crushing of the concrete increased in the exiting walls, the connection performance at the interface was significantly degraded and, consequently, the strength of the jacketed walls was significantly decreased. The flexural strength of the jacketed walls with tee shear connector was estimated considering the full and partial composite actions of the tee shear connector.
        4,000원
        2.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Accumulation of more than 20,000,000 vehicles since the establishment of the quality of life and economic development needs several parking lots and cause crack problem in Korea. Related structures in large cities due to the lack of parking garage attached to secure underground parking structures are actively being built, and the basement parking lot will continue to increase more stories and the trend is expected to be larger. But so far, construction of the underground parking structure is related to a number of problems, including cracks in the structure. Therefore, in this study, repair, reinforcement and a few non-economic losses in the current design criteria are presented. The review of the structure used to current design criteria is to minimize crack and maximize usability.
        4,000원
        3.
        1998.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PSC 연속 평판슬래브의 설계는 부정정 평판슬래브에 대한 정확한 해석의 어려움 등으로 등가보이론과 등가골조이론에 의한 근사식을 수정없이 사용하거나 컴퓨터를 이용한 해석에 의존하고 있으나 해석결과를 간단하게 정확히 평가할 수 있는 기법은 없는 실정이다. 또한 PSC 연속 평판슬래브의 부재력은 긴장재의 곡선형태에 따라 변하므로 실제 설계시 PS 긴장재의 정확한 곡선식을 찾는 것은 매우 중요하다. 본 연구에서는 비부착 PSC 연속 평판슬래브를 설계할 때 기둥과 기둥을 연결하는 PS 긴장재의 기하학적 곡선형태를 결정하는 방법과, PS 긴장력으로 인해 발생하는 평판슬래브의 기둥부 휨모멘트에 대하여 판이론을 기초로 간편하게 계산하는 방법을 제안하였다. 본 연구에서 제안된 이론으로 계산된 PSC 연속 평판슬래브에 대한 해석값과 유한요소 해석에 의한 지점 부모멘트를 비교 검토하여, 본 논문에서 제시한 기법의 타당성을 입증하였다. 따라서 본 연구는 설계자에게 컴퓨터의 해석결과를 간단하고 정확하게 검증할 수 있도록 하였다.
        4,000원
        4.
        2019.10 서비스 종료(열람 제한)
        이 연구에서는 반복하중을 받는 ㄷ자형 강재 댐퍼의 거동을 평가 한다. 연구에 사용된 강재 항복형 댐퍼는 에너지소산부와 긴결부로 구성된다. 에너지소산부의 단면 크기는 15×20mm이며 폭은 120mm, 높이는 90mm이다. 제조가 간편한 ㄷ자 형태를 가지는 강재 댐퍼는 지진하중을 모사할 수 있는 실험기기에 장착되어 반복하중을 받도록 하였다. 목표변위까지 총 5회의 반복하중 실험을 수행한 결과, 강재의 항복 이후 에너지소산능력이 뛰어난 연성적인 거동을 보였을 뿐만 아니라 반복하중을 수행하는 동안 강도의 저하를 보이지 않음을 확인할 수 있었다.
        5.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        이 연구는 유공보강근의 형상에 따른 철근콘크리트 유공 보의 전단저항성능을 평가하기 위하여 4체의 실험체를 제작하여 전단실험을 수행하였다. 실험의 주요변수는 유공의 유무, 유공보강 유무, 유공 보강근의 형상으로 하였으며, 제안 유공 보강근은 시공성을 고려하여 사각형과 마름모형이 혼합된 나선형 형태이다. 실험결과, 이 연구에서 제안된 유공보강근은 유공 주변의 균열을 효과적으로 제어하여 실험체의 전단력 향상에 효과적임을 확인하였다. 또한 현행설계기준은 유공 보강근을 배근한 실험체의 실험결과를 과소평가하는 것으로 나타났다.
        7.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        This paper reports the test results of the floating floor system used to reduce the floor noise of apartment buildings. Recently, many soft resilient materials placing between the reinforced concrete slab and finishing mortar are used. The resilient material should not only reduce the floor impact sound vibration from the floor but also support the load on the floor. Thus, even if soft resilient materials satisfy the maximum limitation of light-weight impact sound and heavy-weight impact sound, these materials may not support the load on the floor. The experimental program involved conducting sixteen sound insulation floating floor specimens. Three main parameters were considered in the experimental investigation: resilient materials, loading location, and layers of floor. Experimental results indicated that the stiffness of resilient material significantly influenced on the structural behavior of floating floor system. In addition, the deflection of the floating concrete floor loaded at the side or coner of the specimen was greater than that of the floor loaded at the center of the specimen. However, the aerated concrete did not effect on the cracking strength of floating floor system.
        8.
        2014.11 KCI 등재 서비스 종료(열람 제한)
        이 논문은 고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 실험결과를 보고한 것이다. 실험체의 주요 실험변수는 접합부 파괴모드, 콘크리트 압축강도, 철근의 정착 방법이다. 모든 실험체는 ACI 352R-02 기준에 바탕을 두어 J파괴와 BJ파괴가 되도록 계획하였다. 주철근은 90도 표준갈고리로 하거나 확대머리철근으로 하였다. 실험결과는 콘크리트 압축강도에 제한되는 현행 ACI 설계 기준식이 고강도 콘크리트를 사용한 보-기둥 접합부의 강도를 다소 과소평가하고 있음을 보여준다. 또한 확대머리철근을 가진 J파괴형 보-기둥 접합부의 강도는 표준갈고리를 가진 접합부보다 약 10% 이상 높게 평가되었다.
        9.
        2013.04 서비스 종료(열람 제한)
        This Paper evaluates the effect of Shear Design Article of KCI 2012 on the isolated footing of 15-story and 25-story frame type apartment buildings of which an apartment unit area is 59m2. As a result, the footing depth of a 15-story building shows 30.7% increase, and 25-story one, 39% increase, respectively. The minimum footing depth of isolated footing to resist pile punching is 750mm for a 15-story building and 830mm for a 25-story one.
        10.
        2013.04 서비스 종료(열람 제한)
        To evaluate underground behavior characteristic according to the ground water level variation, displacement and bending moment using FEM(Plaxis) were analyzed. When the ground water level difference is more than 10m, it were analyzed that effects on underground structures was great
        11.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 철강 공정에서 발생되는 전기로 산화슬래그 골재를 사용한 철근콘크리트 보의 전단 성능을 평가하였다. 이를 위하여 총 6개의 단순지지형 실험체를 제작하여 전단실험을 수행하였다. 주요 실험변수는 골재의 종류와 전단철근의 유무로 하였다. 실험체는 전단경간비가 2.5, 폭 200mm, 유효깊이가 300mm인 직사각형 단면으로 4점가력을 받도록 계획하였다. 기존 강도식을 사용하여 실험체의 전단강도를 예측하였으며, 전단해석모델을 사용한 유한요소해석을 수행하여 전기로 산화슬래그 골재를 사용한 실험체의 전단거동을 예측하였다. 실험결과로부터, 전기로 산화슬래그 골재를 사용한 실험체의 전단 성능은 천연골재를 사용한 실험체와 서로 유사한 것을 확인할 수 있었다.