        1.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The study analyzed performance assessment factors of odor sensors from 4 different manufacturers, including minimum detection limit, humidity stability and temperature stability. In the minimum detection limit assessment, only one electrochemical gas sensor was able to detect ammonia and hydrogen sulfide at the concentration of 5 ppb. The standard deviation ratio was over 10%, and it increased as humidity rose. The range of temperatures in which the electrochemical and photoionization gas sensors could function well was between 25oC and 40oC, and the sensor output values were unstable at low temperatures. Regarding the temperature stability of the metal oxide semiconductor sensor for measuring complex odors, the sensor output values dropped considerably to 0~10oC, and were similar to the concentrations of odor gases generated at 25oC. The results of the test of odor sensor outputs after temperature and humidity pre-treatment revealed that the respective stable output values at 50% humidity and 25oC were similar to the concentrations of manufactured odors. In terms of temperature and humidity stability of the NH3, H2S and Complex odor sensors, all target substances had stable output values at 25~40oC and 50~65% relative humidity, and unstable values at low temperatures and high humidity. Therefore, implementing pretreatment systems including temperature and humidity correction (25~40oC, 50~65% RH) is necessary for the stable use of odor sensors.
        4,900원
        2.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, odor sensors were evaluated in two areas, which were reproducibility of measurements and linearity and correlation of results. The evaluation of linearity and correlation showed that the linearity of the measurement object substance at low, medium and high concentrations of all intervals, and correlation (R2) also appeared to be quite high, at 0.8 to 0.9. Specific performance evaluation results of ammonia, hydrogen sulfide, TVOC and complex odor sensor to the individual substances are somewhat different, but the result have able tendencies. All odor sensors showed detectable in all metrics at 5 ppb concentration in temperature 25oC, humidity 50%. However, there is needs to be determined that in many cases the standard deviation is 10% or more in 5 ppb, and reproducibility appears in the high concentration region with a standard deviation of less than 10%. Because complex odor sensor (MOS sensor) output value is relatively accurate concentration value for the odor and the reaction was stable, MOS sensor is to be considered methods for measuring the complex odor. Reactivity of ammonia, hydrogen sulfide and TVOC odor sensor to the concentration of individual odor substances stably displayed, but the reactivity of the mixture material showed the same trend, however, the hydrogen sulfide and TVOC sensor reactivity were unstable. There is thus a need to maintain the proper temperature and humidity environmental operating condition of odor sensors.
        4,900원
        3.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a correlation analysis of odor was performed in order to assess the reliability and the field applicability of the Odorous gas sensor for continuous real-time monitoring. Hydrogen sulfide was found to have a correlation of 41.5~65.8%, and Ammonia is was found to have very low correlation in less than 200 ppb concentration. Reactivity evaluation result, hydrogen sulfide is the reactivity was higher than the low concentration condition of 100 ppb or less indicated by 31.3~36.4% in the 100 ppb or more high density condition based on the reference density value. For ammonia was very low reactivity in the low-concentration conditions below 200 ppb. TVOC and composite odor assessment did not occur Reactivity no reference concentration value, the specific comparison between both sensors showed a similar trend. In the same Odorous gas sensor accuracy between the result, 40.3~130.6% hydrogen sulfide, ammonia, 69.1~104.9%, TVOCs is 24.7~98.6%, exhibited human odor intensity from 5.5~33.2%.
        4,000원
        4.
        2011.06 KCI 등재 서비스 종료(열람 제한)
        Climate change assessment, together with climate change adaptation process, would be one of the worldwide important issues, and the study on climate change vulnerability indicator has been an essential problem for climate change adaptation. Vulnerability indicator can be used as a good tool to estimate the impact of climate change and to map out the distribution of its vulnerability over the given area both in Korea and other countries. This study addressed the conceptual summary on the assessment of climate change and its adaptation process. Previous studies on how to yield the vulnerability indicators of climate change are reviewed and several previous results of vulnerability indicators applied to Korean provinces are also discussed here.