A literature study was conducted on the management of the pavilion of the royal tomb in the late Joseon Dynasty, focusing on “Gakneung Suri Deungnok(Records relating to the repair of royal tombs)”. This study analyzed the royal tomb management system, organized the types of damage identified in the building, and examined how the damage status was recorded by type. In the above, the records related to the 1675∼1713 repair of three JeongJaGak(Geonwonneung, Sungneung, and Mokneung), which are registered as state-designated cultural properties, are summarized in three aspects: management system, damage status, and expression words. The results of the study are as follows. First, the royal tomb pavilion was regularly inspected by Observator(觀察使) in spring and autumn, and Surunggwan(守陵官) every 5th, and Servant(守僕) regularly inspected every day and night, and also inspected and reported emergency cases of natural disasters or unexpected damage. Second, the damage status of each building was continuously observed and reported for the continuous maintenance of the buildings in the royal tomb. A total of 75 records of damage to the three royal tombs' pavilion were found to have been most frequently inspected, including 19 cases (25.3%), 14 cases (18.7%), 23 cases (30.7%) of the roof, and 19 cases (25.3%) of the roof. Third, the expression of the damage status is confirmed in various ways, such as separation, separation, burst, damage, excitation, moisture, leakage, and exfoliation. Among them, the main damage records were confirmed due to the separation of the base from the peeling, the furniture, cracks, leaks, leaks in the roof, and the collapse of the roof was able to check the damage records.
목적 : 본 연구는 일상생활활동 훈련프로그램을 적용하여 엉덩관절치환술 환자의 일상생활 수행 능력과 작
업치료 인식도 및 만족도에 미치는 효과를 알아보고자 하였다.
연구방법 : 본 연구는 엉덩관절치환술을 받은 노인 40명(실험군 20명, 대조군 20명)이었고, 연구 설계는
비동등성 대조군 전후시차 설계를 적용하였다. 중재는 주 5회 30분씩, 4주간, 총 20회기를 실시하였다.
결과 : 일상생활활동 훈련프로그램 실험군은 일상생활활동 비디오 시청 대조군과 비교하여 일상생활 수행
능력과 작업치료 인식도 및 만족도에서 유의한 차이를 나타냈다.
결론 : 본 연구의 일상생활활동 훈련프로그램은 엉덩관절치환술을 받은 노인들의 일상생활 수행 능력과 작
업치료 인식도 및 만족도를 향상시키어 작업치료의 전문성과 가치를 높였다. 이에 엉덩관절치환술 환자
의 재활을 위한 작업치료 중재 프로그램으로 제안하는 바이다.
This study is objected to investigate the repairing method and the modification period of rafters via the transformation traces left in the superciliums, where repair process takes places frequently. This is the basic research of analyzing the architectural features of Deokkeori, one of the additional-rafter methods. Deokkeori method can be described as using Deokdori in the top section of Hayeon, and placement of Sangyeon above it. This method was started to be used since middle of the Joseon dynasty period(middle 18th Century) and mainly used at 19th Century to resist the transformation caused by repairing. It had been gradually developed from non-application stage to application stage including additional usage of complement.
Odor control technology include absorption, adsorption, incineration and biological treatments. But, most of processes have some problems such as secondary organic acids discharge at the final odor treatment facility. In order to solve the problems for effective treatment of organic acids in odor, it is necessary to develop a new type advanced odor control technology. Some of the technology are plasma only process and plasma hybrid process as key process of the advanced technology. In this study, odor removal performance was compared DBD(Dielectric Barrier Discharge)plasma process with PCHP(plasma catalysis hybrid process) by gaseous ammonia, formaldehyde and acetic acid. Plasma only process by acetic acid obtained higher treatment efficiency above 90%, and PCHP reached its efficiency up to 96%. Acetic acid is relatively easy pollutant to control its concentration other than sulfur and nitrogen odor compounds, because it has tendency to react with water quickly. To test of the performance of DBD plasma process by applied voltage, the tests were conducted to find the dependence of experimental conditions of the applied voltage at 13 kV and 15 kV separately. With an applied voltage at 15 kV, the treatment efficiency was achieved to more higher than 13 kV from 83% to 99% on ammonia, formaldehyde and acetic acid. It seems to the odor treatment efficiency depends on the applied voltage, temperature, humidity and chemical bonding of odors.