검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 105

        41.
        2017.04 구독 인증기관·개인회원 무료
        Numerical behavior of FRP(Fiber Reinforced Polymer) panel in steel frame structure was evaluated through the finite element analysis in this study. In order to numerical analysis, a experimental test results was used to develop a three dimensional finite element model of steel frame specimen. Numerical results of the steel frame specimen was well predicted the experimental behavior of steel frame specimen. Based on the developed three dimensional finite element model of steel frame specimen, the behavior of FRP panel in the steel frame specimen was evaluated. From the numerical analysis results, strength of the steel frame specimen with FRP panel was governed by FRP panel. Also, diagonal compression behavior governed the FRP panel in the steel frame specimen in the numerical analysis results.
        42.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Two steel-frame joint specimens with welding joint parts were constructed and evaluated. Two types of displacement load, monotonic and cyclic, were used to evaluate the steel-frame joint specimens. According to the experimental results, the maximum moment of the cyclic test results was 80% smaller than that of the monotonic test results. Local buckling was observed in the compression area of the H-beam flange. A finite element analysis model based on the experimental results was proposed to analyze the steel-frame joint specimens. The numerical results predicted the experimental behavior of the steel-frame joint specimens well. Therefore, it is possible to use the proposed finite element analysis model to evaluate middle- and low-rise steel-frame buildings constructed in South Korea.
        3,000원
        43.
        2017.04 구독 인증기관·개인회원 무료
        The number of earthquakes is increased recently. A electrical equipment is very important in all electric system because it can make a serious problems in such as nuclear power plants like a black out. So, seismic safety design of electrical equipment is necessary to keep to use the convenience of electronics. In this study, threshold values of electronic equipment was founded out from the numerical results by using seismic load.
        44.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A behavior of FRP(Fiber Reinforced Polymer) panel in a steel frame structure was evaluated through the finite element analysis in this study. In order to numerical analysis, a experimental test results was used to develop a three dimensional finite element model of steel frame specimen. Numerical results of the steel frame specimen was well predicted the experimental behavior of steel frame specimen. Based on the developed three dimensional finite element model of steel frame specimen, the behavior of FRP panel in the steel frame specimen was evaluated. From the numerical analysis results, strength of the steel frame specimen with FRP panel was governed by FRP panel. Also, diagonal compression behavior governed the FRP panel in the steel frame specimen in the numerical analysis results.
        4,000원
        45.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Abstract: In this study, finite element analysis modeling is proposed to evaluate middle- and low-rise steel-frame buildings constructed in South Korea. Two steel-frame joint specimens with welding joint parts were constructed and evaluated. Two types of displacement load, monotonic and cyclic, were used to evaluate the steel-frame joint specimens. According to the experimental results, the maximum moment of the cyclic test results was 80% smaller than that of the monotonic test results. Local buckling was observed in the compression area of the H-beam flange. A finite element analysis model based on the experimental results was proposed to analyze the steel-frame joint specimens. The numerical results predicted the experimental behavior of the steel-frame joint specimens well. Therefore, it is possible to use the proposed finite element analysis model to evaluate middle- and low-rise steel-frame buildings constructed in South Korea.
        4,000원
        46.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In korea, only small amount of nonstructural lightweight concrete is being used through indirect effects such as heat insulation property and soundproofing rather than structural elements due to lack of structural lightweight aggregates and lack of understanding about lightweight concrete development, etc. That`s why structural lightweight concrete to reduce weight has not been put to practical use. This study is a part of high strength lightweight aggregate concrete researches using lightweight aggregates and the purpose of this study is to find out the basic physical characteristics and tension cracking fracture characteristics of lightweight concrete. Crack Mouth Opening Displacement is measured through 3 point flexure experiment about notch beam. Load-CMOD characteristics are examined through rules of countries, characteristics of lightweight concrete and tension cracking fracture experiments. The degree of tensile characteristic alteration according to size changes of specimen and the characteristics about crack surface are analyzed. The changes of softening curve are analyzed and fracture energy is drawn through inverse analysis by the obtained Load-CMOD curve. To decide fracture energy and analysis parametric, inverse analysis is conducted and Ant Colony Method is conducted for optimization and then a way to find out optimal parameterization fracture energy is suggested.
        4,000원
        47.
        2016.04 구독 인증기관·개인회원 무료
        Earthquakes is impossible to predict and occur within very little or no warning. They cause significant damage to property and inflict large human casualties. Seismic retrofit for non-seismic design RC frame has been studied over the years. Although there are many seismic retrofit methods, the seismic retrofit methods are increased weight and physical damage to structures. This study evaluates the seismic performance of RC frame retrofitted with velcro. The specimens were made scale down of actual steel structures, and displacement loads were applied in the trasnverse direction.
        48.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It has been many efforts for reinforcement of existing structure since the number of earthquake has been increased world widely. Especially the occurrence of earthquake surrounding area of Korean peninsular is dramatically increased. Since the buildings in Korea have not been designed to carry the lateral and shear force caused by earthquake, the building will experience massive damages even under moderate earthquake. For this reason, the viscoelastic damper is proposed in this paper to enhance the earthquake resistance of a steel frame buildings. The viscoelastic dampers have been able to increase the overall damping of the structure significantly, hence improving the overall performance of dynamically sensitive structures. In this paper, Viscoelastic dampers designed are consists of FRP panel and viscoelastic material. In this paper, evaluate the performance of the viscoelastic damper through the experiment.
        4,000원
        50.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since it is impossible to predict earthquakes, they involve more casualties and property damage compared to meteorological disasters such as heavy snow and heat waves, which can be predicted through weather forecasts. This has highlighted the need for seismic design and reinforcement. Recently, the use of composite materials as reinforcement has surged because steel plate reinforcement and section enlargement are likely to result in increased weight and physical damage to structures. This study evaluates the seismic performance of panels created from composite materials, and their guide systems. The specimens were miniature versions of actual steel structures, and displacement loads were applied in the transverse direction. Seismic performance was found to improve when structures were reinforced with seismic panels.
        4,000원
        52.
        2015.04 구독 인증기관 무료, 개인회원 유료
        Compared to steel of the same weight in steel concrete structures, fiber reinforced polymer (FRP) is known to have greater strength and better resistance to corrosion. As such, it is being proposed as an effective structural material. Despite its many advantages, FRP has not been rapidly adopted in civil structures. This is because it is more expensive, prone to brittle fracture, and has weak fire resistance. To examine changes in the mechanical properties of FRP and the effectiveness of fire resistant coating, this study conducted tensile tests on coated and uncoated specimens over varying temperature. Glass fiber has excellent fire resistance since it does not melt or burn at high temperatures. However, epoxy is unable to withstand exposure to temperatures exceeding the transition temperature, thus leading to unsatisfactory structural performance and fire resistance. This study investigated the behavioral changes in FRP by exposing the specimens to temperatures ranging from room temperature (approx. 25℃) to 300℃, so as to improve the fire resistance of epoxy.
        3,000원
        53.
        2015.04 구독 인증기관·개인회원 무료
        Because earthquakes occur within very little or no warning, they cause significant damage to property and inflict large human casualties. Seismic design and reinforcement has been extensively studied over the years, for the purpose of reducing damage from earthquakes. Composite materials are being widely used as reinforcement because the use of steel plates and section enlargement are time-consuming methods that leave physical damage to structures. This study assessed the guide system performance of FRP panels created from composite materials. Actual steel structures were reproduced in miniature form, and were subjected to transverse displacement loads. The experiments were carried out by applying two types of FRP panel guide systems to the specimens.
        54.
        2015.04 구독 인증기관·개인회원 무료
        This study is a part of high strength lightweight aggregate concrete researches using lightweight aggregates and the purpose of this study is to find out the basic physical characteristics and tension cracking fracture characteristics of lightweight concrete. Crack Mouth Opening Displacement is measured through three point flexure experiment about embellish notch beam. Load-CMOD characteristics are examined through rules of countries, characteristics of lightweight concrete and tension cracking fracture experiments. The degree of tensile characteristic alteration according to size changes of specimen and the characteristics about crack surface are analyzed. The changes of softening curve are analyzed and fracture energy is drawn through inverse analysis by the obtained Load-CMOD curve. To decide fracture energy and analysis parametric, inverse analysis is conducted and Ant Colony Method is conducted for optimization and then a way to find out optimal parameterization fracture energy is suggested.
        55.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The need to consider torsion in the design of members of a structure has recently been increasing; therefore, many studies on torsion have been carried out. Recent research was focused on the torsional performance of concrete according to the reinforcing materials used. Of particular interest, are torsion studies of beams made of SFRC(steel fiber reinforced concrete), and there has been increasing use of SFRC at construction sites. In contrast, research on the composite PVA-ECC (polyvinyl alcohol-engineered cementitious composite) has only covered its mechanical performance, though it exhibits excellent tensile-strain performance (better than SFRC). Therefore, research on the torsion of concrete beams retrofitted using PVA-ECC is lacking. In this study, the behavior characteristics and performance of reinforced-concrete beams retrofitted by PVA-ECC was investigated experimentally. The experimental results show that the resistance to torsional cracking is increased by PVA-ECC. In addition, the strain on the rebar of the specimen was found to be reduced.
        4,000원
        56.
        2014.04 구독 인증기관 무료, 개인회원 유료
        In this study, material characteristics of glass fiber composite were evaluated by experiment. Tensile, compression and in-plane shear test were performed as test method of ASTM. Velocity of Tensile and compression test was 2mm/min and in-plane shear test was 4mm/min. At the test result, elastic modulus of tensile and compressive were similar. Maximum compressive strength and maximum compressive strain were smaller than the maximum tensile strength and maximum tensile strain.
        3,000원
        57.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the study, tensile, compression and in-plane tests about longitudinal direction of glass fiber were performed. Also, to obtain the material properties of GFRP fabric composite, tensile test was performed. All test were performed by the test method of ASTM. Maximum compressive strength was smaller than the maximum tensile strength at the longitudinal direction test results. Elastic modulus of the tensile and compressive was almost similar at the compression test results in the longitudinal direction. Based on the GFRP fabric composite test results, GF91 was showed good performance at maximum compressive, maximum strain and elastic modulus.
        4,000원
        58.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재 최고 수준의 대순환 모형에서 북동아시아 여름몬순 강도의 계절예측 능력은 낮으나 북서태평양 아열대 고기압 강도의 예측률은 상대적으로 높다. 북서태평양 아열대 고기압은 북서태평양 지역 및 동아시아 지역에서 가장 주된 기후 변동성이다. 본 연구에서 NCEP 계절예측시스템에서 예측된 북서태평양 아열대 고기압의 예측성에 대해 논의될 것이다. 한편, 북동아시아 여름몬순의 경년변동성은 북서태평양 아열대 고기압과 높은 상관성을 가지고 있다. 본 연구에서는 이 관계에 근거하여, NCEP 계절예측시스템과 정준상관분석을 이용한 계절예측 모형을 제안하고 그 예측률을 평가하였다. 이 방법은 북동아시아 지역 여름철 강수량 편차에 대한 계절예측에 있어 통계적으로 유의한 예측성능을 제공한다.
        4,000원
        59.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, flexural strength properties of SC shear walls were investigated through static pushover test. Failure modes and stiffness characteristics of SC shear walls under lateral loads were inspected by analyzing the experimental results. Main failures of unstiffened SC shear walls were found to be the type of bending shear failure due to the unbonding of the steel plate at the concrete interface. The ductility capacity of SC structures was also confirmed to be improved, which is considered to be a confining effect on steel plates in the longitudinal behavior of SC shear walls.
        4,000원
        60.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a shape of connector on seismic reinforced strip, which did not cause any physical damage to concrete column and can repair and reinforcement was decided by using nonlinear finite element analysis. Load displacement was applied on the concrete attached by strip. Stress distribution of connector by extension of concrete were checked. Through stress distribution of this analysis results, the most favorable shape was selected as a shape of the connector.
        4,000원
        1 2 3 4 5