검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2005.02 구독 인증기관 무료, 개인회원 유료
        The box culvert is one of the simple and common structures employed repetitively in construction field. Although parametric computer applications have demonstrated a significant amount of time savings in designing simple and repetitive structures, circulating resultant electronic documents among project participants has not been fully integrated with these applications. This paper presents a development of Web applications to improve the process of a box culvert design and document management using XML and SVG. We developed a parametric Web application in order to facilitate not only engineering design of the box culvert but also management of resultant documents over the Web. This paper presents how XML Data Island and SVG were utilized to generate engineering drawings and display them in the Web page.
        4,000원
        2.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        인장강도가 2,400 MPa인 강연선이 개발되어 콘크리트구조기준 및 KS 규격에 반영되었다. 고강도 프리스트레스트 강연선이 구조물에 적용되기 위해서는 그에 적합한 정착시스템이 함께 사용되어야 한다. 최근에 2,400 MPa 강연선 적용을 위한 포스트텐션 정착구의 개발이 진행되어왔으나, 성능평가에 대한 연구가 미비한 실정이다. 따라서 본 연구에서는 2,400 MPa 강연선을 적용한 포스트텐션 정착구 중 가장 활용도가 높은 9 가닥, 15 가닥, 19 가닥 정착구에 대하여 PTI의 Anchorage Design Zone에 의한 국소구역 구조검토를 실시하였고, ETAG013 및 KCI-PS101에 의한 하중전달성능평가를 수행하였다. 또한 비선형 수치해석을 통해 시험의 적절성을 분석하였다. 그 결과, 2,400 MPa 정착구는 국소구역의 구조성능을 만족하고, 하중전달성능 조건을 만족하는 것으로 나타났다.
        3.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        기존의 LB-DECK는 레티스바와 현장에서 배근되는 철근과의 간섭이 시공성 등을 저하시키는 문제점이 지적되고 있었다. HB-DECK는 레티스바의 형태를 단순화하고, 방향을 주철근 방향에서 배력근 방향으로 전환하였으며 강성을 증가시키기 위해 하면에 리브를 설치하였다. 본 연구에서는 HB-DECK가 프리캐스트 콘크리트 슬래브로써 성능을 발휘할 수 있는지를 검증하고자 하였다. 이를 위해 도로교설계기준(2015)에 의한 구조검증과 HB-DECK와 현장타설 콘크리트와의 합성거동 분석을 위해 정적재하시험을 수행하였다. 범용구조해석 프로그램인 MIDAS FEA를 이용하여 3차원 유한요소해석을 수행하였으며, 해석결과와 실험결과를 비교분석하였다. 그 결과, HB-DECK는 현장타설 콘크리트와 완전한 합성거동을 하는 것으로 나타났으며, 도로교설계기준(2015)에서 요구하는 구조성능을 만족하는 것으로 나타났다.
        4.
        2016.11 KCI 등재 서비스 종료(열람 제한)
        포스트텐션 공법을 적용한 콘크리트 부재의 정착구역에서 정착판 근처의 지압응력은 일반적으로 높은 프리스트레스 하중에 의해 발생한다. 따라서 단면의 효율적인 활용과 콘크리트 부재의 파괴로 이어질 수 있는 균열제어를 위해 적절한 정착판의 크기가 제시되어야 한다. 본 연구에서는 도로교설계기준 및 PTI 등에 의해 사각형 정착판과 원형 정착판의 유효면적에 대한 관계식을 제안하였다. 또한 정착판의 형상 에 따라 형상계수를 제안하였으며, 유한요소해석을 통해 적절성을 분석하였다.
        5.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        Two main parameters were examined such as CSA content and polymer-binder ratio to find effects on the strength, water absorption, chloride ion penetration depth, carbonation depth, length change and chemical resistance of polymer-modified mortar with CSA and EVA polymer powder (EVAPP). As results, compressive, flexural, tensile, adhesive strengths, and length change of the polymer-modified mortar with CSA and EVAPP increases with increasing CSA content and polymer-binder ratio, although the water absorption, chloride ion penetration depth, and carbonation depth decrease with increasing polymer-binder ratio and CSA content, and also the chemical resistance decreases. Such strength and durability development is attributed to the high tensile strength of EVA polymer and the improved bond between cement hydrates and aggregates because of the addition of EVAPP and CSA.
        6.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        Bursting stress in anchorage zone of post tension girder can be estimated based on Guyon’s equation. The major parameters in calculating bursting stress are prestressing force and the distance ratio between concrete edge and anchorage plate. Although Guyon’s equation can be applied to calculate bursting stress for rectangular typed as well as circular typed plate, there is some limitation of accuracy due to 2 dimensional analysis. Therefore this study is proposed to suggest a bursting stress equation based on 3 dimensional finite element method.
        7.
        2014.09 KCI 등재 서비스 종료(열람 제한)
        사장교는 다수의 케이블에 의해 지지되어 복잡한 거동을 하는 구조체이며, 측경간 케이블에 의해 단부교각에서 부반력이 발생한다. 이를 해결하기 위해 적절한 측경간비를 설정해야 하고 앵커교각의 부반력 대책을 강구해야 한다. 부반력 제어 대책으로는 중간교각, 카운터 웨이트 등을 설치하는 방안이 있으며 이에 따라 사장교의 구조계가 결정된다. 밤콩교량은 타당성 검토 단계에서 5경간 사장교로 계획되었다.하지만 시공성 및 경제성 등의 문제로 실시설계 단계에서 3경간 사장교로 변경되었다. 시공성을 확보하기 위하여 중간교각을 배제하였고, 이에 따른 부반력을 제어하기 위해 측경간비를 증가시켰다. 그 결과, 원안 설계에 비하여 시공성, 구조적 안전성, 효율성을 확보할 수 있었다.
        8.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        LB-Deck is one of the widely used member in interior part of girders as a permanent formwork in structures, but it is not easy to apply to the exterior part of girder due to the overturning and excessive deflection. Considering allowable deflection and safety of the exterior part, Precast Concrete Cantilever Deck (PCC-Deck) is proposed with normal LB-Deck in inner part and extended bars of LB-Deck in outer part. Both numerical analyses and experimental tests were compared to check the safety and allowable deflection for 6 types of PCC-Deck, and D-type (with 16 mm top bar, 6 mm lattice bar, 12 mm bottom bar) is suggested as an optimal structural reinforcement to the 28 kN of maximum load and 27.49 mm of final deflection. The load resisting ratio of D-type under working load of 10 kN was about 2.8 times and 77.5% of improvement was observed.