검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2023.05 구독 인증기관·개인회원 무료
        During the decommissioning of a nuclear power plant, the structures must be dismantled to a disposal size. Thermal cutting methods are used to reduce metal structures to a disposal size. When metal is cut using thermal cutting methods, aerosols of 1 μm or less are generated. To protect workers from aerosols in the work environment during cutting, it is necessary to understand the characteristics of the aerosols generated during the cutting process. In this study, changes in aerosol characteristics in the working environment were observed during metal thermal cutting. The cutting was done using the plasma arc cutting method. To simulate the aerosols generated during metal cutting in the decommissioning of a nuclear power plant, a non-radioactive stainless steel plate with a thickness of 20 mm was cut. The cutting condition was set to plasma current: 80 A cutting speed: 100 mm/min. The aerosols generated during cutting were measured using a highresolution aerosol measurement device called HR-ELPI+ (Dekati®). The HR-ELPI+ is an instrument that can measure the range of aerodynamic diameter from 0.006 μm to 10 μm divided into 500 channels. Using the HR-ELPI+, the number concentration of aerosols generated during the cutting process was measured in real-time. We measured the aerosols generated during cutting at regular intervals from the beginning of cutting. The analyzed aerosol concentration increased almost 10 times, from 5.22×106 [1/cm3] at the start of cutting to 6.03×107 [1/cm3] at the end. To investigate the characteristics of the distribution, we calculated the Count Median Aerodynamic Diameter (CMAD), which showed that the overall diameter of the aerosol increased from 0.0848 μm at the start of cutting to 0.1247 μm at the end of the cutting. The calculation results were compared with the concentration by diameter over time. During the cutting process, particles with a diameter of 0.06 μm or smaller were continuously measured. In comparison, particles with a diameter of 0.2 μm or larger were found to increase in concentration after a certain time following the start of cutting. In addition, when the aerosol was measured after the cutting process had ended, particles with a diameter of 0.06 μm or less, which were measured during cutting, were hardly detected. These results show that the nucleation-sized aerosols are generated during the cutting process, which can explain the measurement of small particles at the beginning of cutting. In addition, it can be speculated that the generated aerosols undergo a process of growth by contact with the atmosphere. This study presents the results of real-time aerosol analysis during the plasma arc cutting of stainless steel. This study shows the generation of nucleation-sized particles at the beginning of the cutting process and the subsequent increase in the aerosol particle size over time at the worksite. The analysis results can characterize the size of aerosol particles that workers may inhale during the dismantling of nuclear power plants.
        2.
        2022.10 구독 인증기관·개인회원 무료
        In this study, molten salt experiments were performed using a multi-purpose molten salt experimental loop to evaluate the corrosion and thermodynamic properties of the molten salt. The multi-purpose molten salt experimental loop is made of 1-inch austenitic 316 stainless steel, and 1/4-inch austenitic 316 stainless steel tubes were welded on the surface of a 1-inch pipe to measure temperatures of molten salt. During the experiment, the molten salt leaked due to corrosion of the welded part of the 1/4-inch tube connected to the 1-inch pipe. Therefore, the cause of corrosion damage of the leaked welded part was analyzed. The effect of NaCl-MgCl2 salt selected as the molten salt on corrosion failure was considered. And based on the operation data of molten salt experiments, the time of occurrence of the issue was estimated. Lastly, the cause of corrosion failure was estimated by comparing and analyzing the pipe shape before and after failure using SEM-EDS.
        3.
        2022.10 구독 인증기관·개인회원 무료
        When decommissioning a nuclear power plant, the structure must be made to a disposable size. In general, the cutting process is essential when dismantling a nuclear power plant. Mainly, thermal cutting method is used to cutting metal structures. The aerosols generated during thermal cutting have a size distribution of less than 1 μm. The contaminated structures are able to generate radioactive aerosols in the decommissioning. Radioactive aerosols of 1 μm or less are deposited in the respiratory tract by workers’ breathing, causing the possibility of internal exposure. Therefore, workers must be protected from the risk of exposure to radioactive aerosols. Prior knowledge of aerosols generated during metal cutting is important to ensure worker safety. In this study, the physical and chemical properties of the aerosol were evaluated by measuring the number and mass concentrations of aerosols generated when cutting SUS304 and SA508 using the laser cutting method. High-resolution aerosol measuring equipment (HR-ELPI+, DEKATI) was used to measure the concentration of aerosols. The HR-ELPI+ is an impactor-type aerosol measuring equipment that measures the aerosol number concentration distribution in the aerodynamic diameter range of 6 nm to 10 um in real-time. And analyze the mass concentration of the aerosol according to the diameter range through the impactor. ICP-MS was used for elemental mass concentration analysis in the aerosol. Analytical elements were Fe, Cr, Ni and Mn. For the evaluation of physical and chemical properties, the MMAD of each element and CMAD were calculated in the aerosol distribution. Under the same cutting conditions, it was confirmed that the number concentration of aerosols generated from both materials had a uni-modal distribution with a peak around 0.1 um. CMAD was calculated to be 0.072 um for both SUS304 and SA508. The trend of the CMAD calculation results is the same even when the cutting conditions are changed. In the case of MMAD, it was confirmed that SUS304 had an MMAD of around 0.1 μm in size for only Fe, Cr and Mn. And SA508, Fe, Cr, Ni and Mn were all confirmed to have MMAD around 0.1 μm in size. The results of this study show that a lot of aerosols in the range of less than 1 μm, especially around 0.1 μm in size, are generated when metal is cut using laser cutting. Therefore, in order to protect the internal exposure of workers to laser metal cutting when decommissioning NPPs, it is necessary to protect from nano-sized aerosols beyond micron size.
        9.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, actual odor conditions were investigated in restaurants, livestock facilities, and major odor discharge facilities around daily life, and an odor modeling program was performed to find ways to improve odors in odor discharge facilities. The odor modeling results of restaurants around daily life showed that the complex odor concentration of large restaurants, which are close to residential areas, is higher than the acceptable complex odor standard at the receiving point. It was judged that a plan to increase the height of the restaurant odor outlets and a plan to reduce the amount of odor discharge was necessary. As a result of modeling the life odor of livestock housing facilities, when the distance from the housing facility is far away, the actual emission concentration is much lower than the acceptable emission concentration at the receiving point. It was judged that such facilities need to be reviewed for ways to reduce the emission of odorous substances, such as sealing the livestock housing facilities or improving the livestock environment. The main odor emission business sites that show complex odor concentration as 1,000 times or greater than the outlet odor emission standard were businesses associated with surfactant preparation, compounded feed manufacturing, textile dyeing processing, and waste disposal. Due to the separation distance and high exhaust gas flow rate, it was found that odor reduction measures are necessary. In this study, it was possible to present the allowable odor emission concentration at the discharge facilities such as restaurants, livestock houses, and industrial emission facilities by performing the process of verifying the discharge concentration of the actual discharge facility and the result of living odor modeling. It is believed that suitable odor management and prevention facilities can be operated.
        4,200원
        10.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, real-time monitoring of air quality using a real-time mobile monitoring system was conducted to identify the emission characteristics and current status of air pollutants and odorous substances that are mainly generated in domestic dyeing industrial areas and to trace the pollutant sources. The concentration of toluene in the industrial area was detected up to 926.4 ppb, which was 3 to 4 times higher than that of other industrial areas. The concentration of methylethylketone was 124.7 ppb and the concentration of dichloromethane was 129.5 ppb. Acrolein concentration was highest at E point at 521.6 ppb, methanol concentration was highest at D point at 208.8 ppb, and acetone concentration was highest at M and N points at 549.3 ppb. The most frequently detected concentration of pollutants in the air quality monitoring results in the industrial area was, in descending order, toluene > methanol > acrolein > dichloromethane > acetone, which was similar to the chemical emissions used in the industrial area by the Pollutant Release and Transfer Register data. The concentration of odorous substances measured in real time was compared with the concentration of minimum detection, and the concentration of hydrogen sulfide was about 10 times higher than the concentration of minimum detection at A point, which was judged to be the main odorous cause of A point. In the future, if the real-time mobile measurement system is constructed to automatically connect wind direction/wind speed, PRTR (Pollutant Release and Transfer Register) data and SEMS (Stack Emission Management System) data, etc., it was judged that more accurate monitoring could be performed.
        4,000원
        11.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the grid field olfactory odor method was supplemented to the domestic situation in the surrounding areas of a domestic science industrial complex. The actual condition of the occurrence of odor frequency in the field was then investigated over the first period of late spring to summer and the second period of autumn in 2017. The frequency of odor occurrence in the area around the science industrial complex was increased as odor discharge facilities in the nearby area were concentrated. The odor occurrence frequency of the total period was 0.09~0.28, that of the first period was 0.08~0.32, and that of the second period was 0.05~0.25. The odor occurrence frequency in summer was higher than in autumn. The frequency by which the measurement of odor occurrence by smell type was most dominant was mainly smell of chemicals, plastics, and livestock houses during the first period, and the smell of chemicals, burning gases, and plastics during the second period. And the frequency of each smell type was judged to be different according to season. The odor occurrence frequency was measured as higher than 0.15, which is the standard of Germany's odor frequency in an industrial area, and it was judged that measures for odor management in the region were necessary. Since most of the odor discharge facilities are non-continuous systems and the odor generation frequency is more important than the concentration of the minimum detection concentration, it was judged that the German grid method can reflect the odor occurrence characteristics of the odor complaints or receptors for a certain period of time compared to the domestic measurement method. In the future, it was judged that the field olfactory odor method would be able to replace the evaluation method of odor assessment in Korea with the survey method of odor assessment under actual conditions in areas where it is difficult to access the odor discharge source or the receptor where odor complaints occur.
        4,000원
        12.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the current status of odor and to examine the application method of the odor emission standard in a restaurant environment. The complex odor dilution concentrations (“times”) and odor compounds were measured in 8 restaurants. The highest complex odor dilution times were 966 in outlets and 97 in site boundaries of C restaurants. The average complex odor dilution times were 632 in outlets and 29 in site boundaries, which exceeded the allowable odor discharge standard of residential areas. Eighteen of the 22 specified offensive odor substances were detected. Aldehyde-type substances showed high concentrations, and the highest concentration of ethanol was detected in addition to the designated odorous substances. Dichloromethane, benzene, and phenol, which are harmful air pollutants, were also detected. The odorant concentrations of restaurants were found to exceed the odor standard threshold in A, B, and F restaurants. Upon review of the Japanese-style odor index respective to restaurant odor, it is difficult to apply an equivalent emission allowance standard as the permissible emission standard of the workplace. It is necessary to regulate emission standards by different emission standards. In the future, it will be necessary to determine how to measure the odor index and how to apply the odor emission standard to everyday facilities, such as restaurants, grocery stores, etc.
        5,200원