검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 31

        21.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        KCI 2012 and ACI318-11 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. In ACI318-11, the confinement factor, such as transverse reinforcement factor, is not used to calculate the development length of headed bars. The purpose of this experimental study is to evaluate the effect of confinement details to the lap splice performance of headed deformed reinforcing bars in grade SD400 and SD500. The confinement details are stirrups and tie-down bars in lap zone. Test results showed that specimens with only stirrups had the brittle failure and could not increase lap strengths, and that specimens with composite confinements by stirrups and tie-down bars had the flexural strengths over than nominal flexural strengths. Stirrups with tie-down bars can have an effect on improvement in lap splice of headed bars in grade SD400 and SD500.
        22.
        2014.10 서비스 종료(열람 제한)
        The purpose of this experimental study is to evaluate that KCI2012 equation for the development length, ldt, of headed bars can be used to calculate the lap length of headed deformed bars in grade SD400~500 for high strength concrete. Test results showed that specimens with lap lengths equal to 1.3ldt had maximum flexural strengths as 0.84~0.90 times as the nominal flexural strengths. These observations indicate that 1.3 is unsuitable to the tensile lap length of headed deformed bars in grade SD400~500 for high strength concrete.
        23.
        2014.09 KCI 등재 서비스 종료(열람 제한)
        현행 콘크리트구조기준 (KCI2012) 및 ACI318-11에서 B급이음된 일자형 이형철근에 대하여 인장력에 대한 겹침이음길이를 정착길이의 1.3배로 산정하고 있다. 동일 기준에서 확대머리 이형철근의 정착길이를 제시하고 있지만 겹침이음상세에 대한 규정은 없다. 이에 본연구에서는 400MPa과 500MPa 설계기준항복강도를 가지는 확대머리 이형철근의 겹침이음실험을 실시함으로써, 기준의 정착길이식을 겹침이음설계에 적용가능한 지를 평가하고자 하였다. 실험결과, SD400과 SD500의 설계기준항복강도를 적용한 확대머리 이형철근에 대하여 겹침이음길이를 정착길이의 1.3배로 산정할 경우, 실험 최대휨강도가 공칭휨강도에 비하여 16~31% 크게 평가되었고 연성적인 휨파괴 거동을 나타내었다. 따라서, 이들 철근에 대해 정착길이 1.3배의 겹침이음길이로 설계함으로써 강도 및 변형성능 측면에서 겹침이음 성능을확보할 수 있는 것으로 사료된다.
        24.
        2013.04 서비스 종료(열람 제한)
        Diagonally reinforced concrete coupling beam has complicated reinforcement details. To solve this problem, it is necessary to develop the alternative reinforcement details. The objective of this study is to investigate strain characteristics of coupled shear wall according to the replacement ratio of headed-bar.
        25.
        2013.04 서비스 종료(열람 제한)
        Reinforced concrete coupled shear wall systems in medium and high-rise construction, where RC beams couple two or more RC walls have been frequently used. The objective of this study is to investigate seismic behavior of coupled shear wall according to the replacement ratio of headed-bar.
        26.
        2012.11 서비스 종료(열람 제한)
        Reinforced concrete coupled shear wall systems in medium and high-rise construction, where RC beams couple two or more RC walls have been frequently used. The objective of this study is to investigate seismic performance of coupling beam with headed bar.
        27.
        2012.11 서비스 종료(열람 제한)
        The coupling beams provide transfer of vertical forces between adjacent shear walls in coupled shear wall system, which creates a frame-like coupling action that resists lots of the total overturning moment induced by the wind load or seismic load. The purpose of this study is to investigate the strain characteristics performance of coupling beams with headed bar.
        28.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        본 연구는 철근콘크리트 기둥 횡보강근의 형태 특히 크로스타이의 유무 및 단부 정착형태에 따른 내진성능을 평가하기 위한 실험연구이다. 계획된 실험변수인 크로스타이의 유무, 크로스타이의 단부 정착형태(헤드형 또는 갈고리형), 그리고 기둥 축응력의 크기에 따라 총 5개의 기둥 실험체를 제작한 뒤 일정 축력하에 횡방향 반복가력 실험을 수행한 후, 크로스타이가 철근콘크리트 기둥의 구조성능에 미치는 영향을 평가하였다. 실험으로부터, 크로스타이가 없이 띠철근만으로 횡보강된 기둥은, 낮은 횡력에서 균열과 함께 띠철근이 휨변형한 뒤 코아 콘크리트가 탈락되는 파괴양상을 보인 반면에 크로스타이가 있는 기둥은 균열이 발생한 이후에도 띠철근이 휨변형과 주근좌굴을 억제하고 코아 콘크리트를 효과적으로 구속하여 내력 및 연성을 증진시키는 것으로 나타났다. 횡방향 대변형시, 갈고리형 크로스타이는 90˚ 갈고리 부분이 펴지면서 코아 콘크리트가 탈락되는 양상을 보이지만 헤드형 크로스타이는 대변형 시에도 헤드가 매우 효과적으로 띠철근과 주근을 구속하여 높은 내력과 연성능력을 발휘하는 것으로 나타났다.
        29.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        철근콘크리트 보-기둥 접합부는 철근의 복합적인 배근으로 인하여 시공성이 저하되고 철근의 정착공간이 협소하여 정착파괴가 발생할 가능성이 높다. 또한 지진하중 하에서 기둥 또는 접합부의 파괴는 구조물 전체의 파괴를 야기할 수 있기 때문에 기둥 표면에서 일정한 거리이상 떨어진 보에 소성힌지를 발생시켜 보의 파괴가 선행된 후에 기둥 및 접합부가 파괴되는 강기둥-약보의 설계 개념을 적용하여 구조물의 안전성을 확보하고 있다. 본 연구에서는 이러한 접합부의 강도 증가 및 시공성 향상을 도모하고 소성힌지를 보의 내측방향으로 이동시키기 위한 방안으로 보 주인장 철근과 접합부 보강 철근으로 헤디드 바를 활용하고자 하였다. 이를 위해 헤디드 바로 보강된 철근콘크리트 보-기둥 접합부에 대해 3차원 유한요소 해석을 수행하였다. 해석결과의 정확성을 검증하기 위하여 선행연구자에 의해 실험된 부재와 동일한 변수에 대한 해석을 수행하여 그 결과를 비교하였으며, 헤디드바의 우수성을 확인하기 위한 변수를 추가하여 해석을 수행하였다. 해석결과 보 주인장 철근의 정착방법으로 헤디드 바를 사용함으로써 유사한 구조성능 하에서 시공성 향상을 도모할 수 있음을 확인하였다. 또한 헤디드 바를 접합부에 보강함으로써 설계자가 의도한 위치에 소성힌지를 발생시킬 수 있었으며, 주기하중 하에서 에너지 소산능력의 증가, 강성 감소의 최소화 및 극한응력을 향상시키는 결과를 얻었다.
        30.
        2008.09 KCI 등재 서비스 종료(열람 제한)
        이 연구는 2006년 월에 전라남도 여수시 오천동 주변 해역의 하천과 연계된 기수구역에서 간조시 돌 밑부분에 부착된 큰미끈망둑의 난을 채집하여 전남대학교 자원생물실험실로 운반하여 실내사육하면서 난발생 과정 및 자치어 형태 발달을 관찰하였다. 큰미끈망둑의 수정란은 난막이 타원형으로 부풀어 장경이 (n=20), 단경이 (n=20)로 투명하였고, 난막의 기부에는 많은 부착사가 있어서 돌에 부착하는 부착란으로 다수의 소유구를 가지고 있었다. 부화에 소요된 시간